본문으로 건너뛰기
← 뒤로

Surface electric field enhanced biosensor based on symmetrical U-tapered HCF structure for gastric carcinoma biomarker trace detection.

Biosensors & bioelectronics 2024 Vol.264() p. 116666

Li B, Wang Q

📝 환자 설명용 한 줄

In this article, a novel U-tapered hollow-core fiber (HCF) surface plasmon resonance (SPR) biosensor coated with PtS for early-stage gastric carcinoma (GC) diagnosis was demonstrated.

이 논문을 인용하기

BibTeX ↓ RIS ↓
APA Li B, Wang Q (2024). Surface electric field enhanced biosensor based on symmetrical U-tapered HCF structure for gastric carcinoma biomarker trace detection.. Biosensors & bioelectronics, 264, 116666. https://doi.org/10.1016/j.bios.2024.116666
MLA Li B, et al.. "Surface electric field enhanced biosensor based on symmetrical U-tapered HCF structure for gastric carcinoma biomarker trace detection.." Biosensors & bioelectronics, vol. 264, 2024, pp. 116666.
PMID 39146771

Abstract

In this article, a novel U-tapered hollow-core fiber (HCF) surface plasmon resonance (SPR) biosensor coated with PtS for early-stage gastric carcinoma (GC) diagnosis was demonstrated. The article proposed the first investigation to detect Interleukin-10 (IL10) and Interleukin-1β (IL1β) which were associated with the risk of developing gastric carcinoma, using optical fiber SPR technology. Herein, the sensitivity of sensor was effectively improved through a combination of tapered and U-shaped structures. Additionally, to further enhance the detection capability, two-dimensional material PtS was utilized to increase the surface electric field intensity of the sensor. Simultaneously, optimization of structural parameters such as taper ratio, bending diameters, and Au film thickness was conducted. Ultimately, the designed sensor achieved a remarkable sensitivity of 13210 nm/RIU within the refractive index (RI) range of 1.33-1.37. The sensor demonstrated exceptional performance, achieving sensitivities of 3.64 nm/(ng/ml) and 7.46 nm/(ng/ml) for the detection of IL10 and IL1β biomarkers, respectively, along with limit of detection (LOD) of 2.74 pg/ml and 1.33 pg/ml, and successfully detecting the presence of these biomarkers in the serum of gastric cancer patients. Overall, the proposed sensor exhibits significant potential in early gastric cancer detection and advances the application of optical fiber SPR sensors in trace biodetection.

MeSH Terms

Humans; Stomach Neoplasms; Surface Plasmon Resonance; Biomarkers, Tumor; Limit of Detection; Interleukin-1beta; Interleukin-10; Biosensing Techniques; Optical Fibers; Equipment Design; Gold

같은 제1저자의 인용 많은 논문 (5)