Direct deep learning analysis of three-dimensional automated breast ultrasound videos with reading mode optimization for breast cancer diagnosis.
[PURPOSE] This study aimed to develop and evaluate a deep learning model that directly analyzes three-dimensional automated breast ultrasound videos (DL-3DABUV) to assist breast cancer diagnosis, and
- 표본수 (n) 437
- Sensitivity 82.1%
- Specificity 81.5%
APA
Guo Y, Wang C, et al. (2026). Direct deep learning analysis of three-dimensional automated breast ultrasound videos with reading mode optimization for breast cancer diagnosis.. Ultrasonography (Seoul, Korea), 45(1), 80-91. https://doi.org/10.14366/usg.25096
MLA
Guo Y, et al.. "Direct deep learning analysis of three-dimensional automated breast ultrasound videos with reading mode optimization for breast cancer diagnosis.." Ultrasonography (Seoul, Korea), vol. 45, no. 1, 2026, pp. 80-91.
PMID
41566994
Abstract
[PURPOSE] This study aimed to develop and evaluate a deep learning model that directly analyzes three-dimensional automated breast ultrasound videos (DL-3DABUV) to assist breast cancer diagnosis, and to examine the optimal reading mode for clinical implementation.
[METHODS] This retrospective study included 547 patients (285 benign, 262 malignant), who were randomly assigned to a training set (n=437) and a test set (n=110). The DL-3DABUV model, built using ResNet50 and multi-instance learning, was trained by directly analyzing videos without image selection or manual annotation. Six radiologists (three experienced and three novice) evaluated the test set under three modes: independent-reading (without DL-3DABUV), second-reading (without prior knowledge of DL-3DABUV results), and concurrent-reading (after viewing DL-3DABUV results). The diagnostic performance of DL-3DABUV, experienced radiologists, and novice radiologists was compared. Reading times across the three modes were also assessed.
[RESULTS] Compared to experienced radiologists in independent reading, DL-3DABUV showed no significant differences in area under the receiver operating characteristic curve (AUC) (0.82 vs. 0.83), sensitivity (82.1% vs. 81.6%), or specificity (81.5% vs. 88.3%) (all P>0.05). DL-3DABUV exhibited higher AUC and specificity than novice radiologists in independent-reading (0.82 vs. 0.68, P<0.001; 81.5% vs. 57.4%, P<0.001). However, novice performance reached parity with DL-3DABUV in both second-reading and concurrent-reading. No significant differences in diagnostic performance were observed between second-reading and concurrent-reading. Concurrent reading significantly reduced reading time by 33.6 seconds compared with second-reading (P<0.001).
[CONCLUSION] DL-3DABUV achieves diagnostic performance comparable to experienced radiologists and enhances diagnostic accuracy for novices. Concurrent reading provides a more efficient workflow by reducing reading time while maintaining diagnostic performance.
[METHODS] This retrospective study included 547 patients (285 benign, 262 malignant), who were randomly assigned to a training set (n=437) and a test set (n=110). The DL-3DABUV model, built using ResNet50 and multi-instance learning, was trained by directly analyzing videos without image selection or manual annotation. Six radiologists (three experienced and three novice) evaluated the test set under three modes: independent-reading (without DL-3DABUV), second-reading (without prior knowledge of DL-3DABUV results), and concurrent-reading (after viewing DL-3DABUV results). The diagnostic performance of DL-3DABUV, experienced radiologists, and novice radiologists was compared. Reading times across the three modes were also assessed.
[RESULTS] Compared to experienced radiologists in independent reading, DL-3DABUV showed no significant differences in area under the receiver operating characteristic curve (AUC) (0.82 vs. 0.83), sensitivity (82.1% vs. 81.6%), or specificity (81.5% vs. 88.3%) (all P>0.05). DL-3DABUV exhibited higher AUC and specificity than novice radiologists in independent-reading (0.82 vs. 0.68, P<0.001; 81.5% vs. 57.4%, P<0.001). However, novice performance reached parity with DL-3DABUV in both second-reading and concurrent-reading. No significant differences in diagnostic performance were observed between second-reading and concurrent-reading. Concurrent reading significantly reduced reading time by 33.6 seconds compared with second-reading (P<0.001).
[CONCLUSION] DL-3DABUV achieves diagnostic performance comparable to experienced radiologists and enhances diagnostic accuracy for novices. Concurrent reading provides a more efficient workflow by reducing reading time while maintaining diagnostic performance.
같은 제1저자의 인용 많은 논문 (5)
- Treatment of Chin Retrusion With Botulinum Toxin Plus Hyaluronic Acid Filler in Comparison With Hyaluronic Acid Filler Alone: A Randomized, Evaluator-Blinded, Controlled Study.
- Effect of a New Hyaluronic Acid Hydrogel Dermal Filler Cross-Linked With Lysine Amino Acid for Skin Augmentation and Rejuvenation.
- Efficacy and safety of hyaluronic acid fillers for lip augmentation in a Chinese population.
- Artificial Intelligence in melanoma research: a bibliometric analysis.
- Dual Aptamers-Based SETDB1 PROTACs as Effective Anti-Tumor Strategies for Breast Cancer.