Direct deep learning analysis of three-dimensional automated breast ultrasound videos with reading mode optimization for breast cancer diagnosis.

Ultrasonography (Seoul, Korea) 2026 Vol.45(1) p. 80-91

Guo Y, Wang C, Liu Y, Pang Y, Ge R, Li W, Liu L, Zhang Q, Chen L

📝 환자 설명용 한 줄

[PURPOSE] This study aimed to develop and evaluate a deep learning model that directly analyzes three-dimensional automated breast ultrasound videos (DL-3DABUV) to assist breast cancer diagnosis, and

🔬 핵심 임상 통계 (초록에서 자동 추출 — 원문 검증 권장)
  • 표본수 (n) 437
  • Sensitivity 82.1%
  • Specificity 81.5%

이 논문을 인용하기

BibTeX ↓ RIS ↓
APA Guo Y, Wang C, et al. (2026). Direct deep learning analysis of three-dimensional automated breast ultrasound videos with reading mode optimization for breast cancer diagnosis.. Ultrasonography (Seoul, Korea), 45(1), 80-91. https://doi.org/10.14366/usg.25096
MLA Guo Y, et al.. "Direct deep learning analysis of three-dimensional automated breast ultrasound videos with reading mode optimization for breast cancer diagnosis.." Ultrasonography (Seoul, Korea), vol. 45, no. 1, 2026, pp. 80-91.
PMID 41566994
DOI 10.14366/usg.25096

Abstract

[PURPOSE] This study aimed to develop and evaluate a deep learning model that directly analyzes three-dimensional automated breast ultrasound videos (DL-3DABUV) to assist breast cancer diagnosis, and to examine the optimal reading mode for clinical implementation.

[METHODS] This retrospective study included 547 patients (285 benign, 262 malignant), who were randomly assigned to a training set (n=437) and a test set (n=110). The DL-3DABUV model, built using ResNet50 and multi-instance learning, was trained by directly analyzing videos without image selection or manual annotation. Six radiologists (three experienced and three novice) evaluated the test set under three modes: independent-reading (without DL-3DABUV), second-reading (without prior knowledge of DL-3DABUV results), and concurrent-reading (after viewing DL-3DABUV results). The diagnostic performance of DL-3DABUV, experienced radiologists, and novice radiologists was compared. Reading times across the three modes were also assessed.

[RESULTS] Compared to experienced radiologists in independent reading, DL-3DABUV showed no significant differences in area under the receiver operating characteristic curve (AUC) (0.82 vs. 0.83), sensitivity (82.1% vs. 81.6%), or specificity (81.5% vs. 88.3%) (all P>0.05). DL-3DABUV exhibited higher AUC and specificity than novice radiologists in independent-reading (0.82 vs. 0.68, P<0.001; 81.5% vs. 57.4%, P<0.001). However, novice performance reached parity with DL-3DABUV in both second-reading and concurrent-reading. No significant differences in diagnostic performance were observed between second-reading and concurrent-reading. Concurrent reading significantly reduced reading time by 33.6 seconds compared with second-reading (P<0.001).

[CONCLUSION] DL-3DABUV achieves diagnostic performance comparable to experienced radiologists and enhances diagnostic accuracy for novices. Concurrent reading provides a more efficient workflow by reducing reading time while maintaining diagnostic performance.