[BACKGROUND] Microneedling (MN) and microneedling-radiofrequency (MN-RF) result in skin rejuvenation and skin exposure to pathogens.

이 논문을 인용하기

BibTeX ↓ RIS ↓
APA Sasaki GH (2019). The Significance of Trans-Epidermal Water Loss After Microneedling and Microneedling-Radiofrequency Procedures: Histological and IRB-Approved Safety Study.. Aesthetic surgery journal. Open forum, 1(3), ojz017. https://doi.org/10.1093/asjof/ojz017
MLA Sasaki GH. "The Significance of Trans-Epidermal Water Loss After Microneedling and Microneedling-Radiofrequency Procedures: Histological and IRB-Approved Safety Study.." Aesthetic surgery journal. Open forum, vol. 1, no. 3, 2019, pp. ojz017.
PMID 33791612

Abstract

[BACKGROUND] Microneedling (MN) and microneedling-radiofrequency (MN-RF) result in skin rejuvenation and skin exposure to pathogens.

[OBJECTIVES] The aim was to determine histopathological changes of needle-depth injuries in preauricular skin and measure time-dependent repair of transepidermal water loss (TEWL) in subjects.

[METHODS] MN and MN-RF procedures were performed at 0.5- and 1.5-mm needle depths on preauricular skin strips from a facelift patient. In 10 subjects, MN and MN-RF procedures were performed at 0.5-mm needle lengths on 6 marked opposing face and body sites. MN and MN-RF at 1.5-mm needle lengths were also carried out on each subject's midface skin lateral to the nasolabial fold. TEWL measurements were recorded with a calibrated DermaLab Cortex device (Hadsund, Denmark).

[RESULTS] Histological examination confirmed that the penetration depths of microchannels closely approximated the 0.5- or 1.5-mm needle lengths. In addition, MN-RF exhibited zones of coagulation injury at the distal end of the channel. After MN or MN-RF at 0.5-mm needle length, TEWL values were greatest immediately after needling to scalp, midface, neck, chest, arm, and thigh sites and remained slightly higher than baseline throughout the 48-h evaluation period. TEWL measurements after MN or MN-RF at 1.5-mm needle length resulted in the highest- and longest-lasting values throughout the 2-day observation period.

[CONCLUSIONS] MN and MN-RF devices are novel devices that require further investigation into optimal treatment parameters and protocols, patient selection, and protection against intrusion of external pathogens and reactive cosmeceutical ingredients with barrier repair.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
시술 facelift 안면거상술 dict 1
해부 skin scispacy 1
해부 TEWL → transepidermal water loss scispacy 1
해부 barrier scispacy 1
합병증 preauricular skin scispacy 1
합병증 nasolabial scispacy 1
합병증 scalp scispacy 1
합병증 thigh sites scispacy 1
약물 Microneedling scispacy 1
약물 [BACKGROUND] Microneedling scispacy 1
약물 [CONCLUSIONS] MN scispacy 1
질환 coagulation injury scispacy 1
질환 intrusion of external pathogens scispacy 1
질환 Cortex scispacy 1
질환 TEWL → transepidermal water loss scispacy 1
기타 TEWL → transepidermal water loss scispacy 1
기타 skin lateral scispacy 1
기타 Hadsund scispacy 1

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

같은 제1저자의 인용 많은 논문 (5)

관련 논문