Three-Dimensional Topography of the Emerging Point of the Ophthalmic Artery.
Abstract
[BACKGROUND] During periorbital noninvasive and surgical procedures, there is the risk of iatrogenic injury to the emerging point of the ophthalmic artery. This study aimed to determine the three-dimensional location of the emerging point of the ophthalmic artery and to provide clinicians with anatomical information that would help them to avoid associated complications.
[METHODS] Seventeen hemifaces of the emerging point of the ophthalmic artery from 10 Korean and seven Thai cadavers were dissected and scanned by a three-dimensional scanner. The emerging points of the ophthalmic artery of 30 healthy Korean volunteers were also detected using an ultrasound imaging system.
[RESULTS] The transverse distance from the medial canthus to the emerging of the ophthalmic artery was 3.8 ± 1.0 mm medially, and the vertical distance was 14.0 ± 2.9 mm superiorly. The transverse distance from the midline was 16.5 ± 1.7 mm to the emerging point of the ophthalmic artery and 20.0 ± 2.0 mm to the medial canthus. The measured depth from the skin surface to the emerging point of the ophthalmic artery was 4.8 ± 1.7 mm by means of three-dimensional scanning and 4.5 ± 1.1 mm using ultrasound detection. The vertical distance from the inferior margin of the superior orbital rim to the emerging point of the ophthalmic artery was 5.3 ± 1.4 mm.
[CONCLUSION] These data inform clinicians about the anatomical three-dimensional location of the emerging point of the ophthalmic artery, which will help them to avoid iatrogenic injury when they are performing periorbital clinical procedures.
[METHODS] Seventeen hemifaces of the emerging point of the ophthalmic artery from 10 Korean and seven Thai cadavers were dissected and scanned by a three-dimensional scanner. The emerging points of the ophthalmic artery of 30 healthy Korean volunteers were also detected using an ultrasound imaging system.
[RESULTS] The transverse distance from the medial canthus to the emerging of the ophthalmic artery was 3.8 ± 1.0 mm medially, and the vertical distance was 14.0 ± 2.9 mm superiorly. The transverse distance from the midline was 16.5 ± 1.7 mm to the emerging point of the ophthalmic artery and 20.0 ± 2.0 mm to the medial canthus. The measured depth from the skin surface to the emerging point of the ophthalmic artery was 4.8 ± 1.7 mm by means of three-dimensional scanning and 4.5 ± 1.1 mm using ultrasound detection. The vertical distance from the inferior margin of the superior orbital rim to the emerging point of the ophthalmic artery was 5.3 ± 1.4 mm.
[CONCLUSION] These data inform clinicians about the anatomical three-dimensional location of the emerging point of the ophthalmic artery, which will help them to avoid iatrogenic injury when they are performing periorbital clinical procedures.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | artery
|
scispacy | 1 | ||
| 해부 | midline
|
scispacy | 1 | ||
| 해부 | skin
|
scispacy | 1 | ||
| 합병증 | periorbital
|
scispacy | 1 | ||
| 합병증 | medial canthus
|
scispacy | 1 | ||
| 약물 | ± 1.0 mm medially
|
scispacy | 1 | ||
| 약물 | ± 2.9 mm
|
scispacy | 1 | ||
| 약물 | [BACKGROUND]
|
scispacy | 1 | ||
| 질환 | injury to the emerging point of the ophthalmic artery
|
scispacy | 1 | ||
| 기타 | artery
|
scispacy | 1 | ||
| 기타 | hemifaces
|
scispacy | 1 | ||
| 기타 | cadavers
|
scispacy | 1 |
MeSH Terms
Aged; Aged, 80 and over; Cadaver; Dissection; Face; Female; Humans; Iatrogenic Disease; Imaging, Three-Dimensional; Male; Ophthalmic Artery; Plastic Surgery Procedures; Surgery, Plastic; Ultrasonography, Doppler