pH-responsive albumin-mimetic synthetic nanoprobes for magnetic resonance/fluorescence imaging of thyroid cancer.

1/5 보강
Journal of biomedical materials research. Part A 2024 Vol.112(10) p. 1712-1724
Retraction 확인
출처

Xie Z, Hao L, Liu J, Guo C, Jia Q, Wu S, Li F, Li C, Li Z

📝 환자 설명용 한 줄

The combination of magnetic resonance and fluorescence imaging in dual-modality imaging not only resolves the limitations of conventional single molecular imaging techniques in terms of specificity, s

이 논문을 인용하기

↓ .bib ↓ .ris
APA Xie Z, Hao L, et al. (2024). pH-responsive albumin-mimetic synthetic nanoprobes for magnetic resonance/fluorescence imaging of thyroid cancer.. Journal of biomedical materials research. Part A, 112(10), 1712-1724. https://doi.org/10.1002/jbm.a.37731
MLA Xie Z, et al.. "pH-responsive albumin-mimetic synthetic nanoprobes for magnetic resonance/fluorescence imaging of thyroid cancer.." Journal of biomedical materials research. Part A, vol. 112, no. 10, 2024, pp. 1712-1724.
PMID 38699811 ↗
DOI 10.1002/jbm.a.37731

Abstract

The combination of magnetic resonance and fluorescence imaging in dual-modality imaging not only resolves the limitations of conventional single molecular imaging techniques in terms of specificity, sensitivity, and resolution but also expands the possibilities of molecular imaging techniques in diagnostics and therapeutic monitoring. Herein, a novel pH-responsive magnetic resonance/near-infrared fluorescence (MR/NIRF) nanoprobe (MnO@BSA-Cy5.5) was successfully prepared by biomineralizing manganese dioxide (MnO) with bovine serum albumin (BSA) while coupling fluorescent dye Cy5.5 for precise tumor detection and visualization. The synthesized MnO@BSA-Cy5.5 nanoprobes were spherical particles of approximately 22.62 ± 3.31 nm in size, and their relaxation rates and T imaging signals were activated-enhanced in an acidic environment. Cytotoxicity assay and hematoxylin and eosin staining demonstrated that MnO@BSA-Cy5.5 had low cytotoxicity and good biocompatibility. More importantly, active targeting via solid tumor albumin-binding protein receptor and enhanced permeability and retention effect, the probe can be specifically aggregated to the tumor site of the 8305C tumor model and exhibit excellent MR/NIRF imaging properties. Our results show that MnO@BSA-Cy5.5 has high resolution and sensitivity in tumor imaging and is expected to be applied as an MR/NIRF contrast agent for accurate diagnosis of thyroid cancer.