Linear accelerator selection: impact on feasibility dose-volume histograms and practicality in dose reduction for organs at risk during prostate volumetric-modulated arc therapy.
1/5 보강
PICO 자동 추출 (휴리스틱, conf 2/4)
유사 논문P · Population 대상 환자/모집단
30 patients with prostate cancer, with planning target volume excluding the rectum (PTV-R) and OAR contours created by three planners.
I · Intervention 중재 / 시술
추출되지 않음
C · Comparison 대조 / 비교
추출되지 않음
O · Outcome 결과 / 결론
[CONCLUSIONS] These findings highlight that the choice of the linear accelerator significantly impacts OAR dose reduction. In prostate VMAT, TrueBeam demonstrated superior rectal and bladder dose reduction compared to Halcyon, underscoring the importance of selecting the appropriate device to optimize treatment planning and minimize variability.
[BACKGROUND] The quality of volumetric-modulated arc therapy (VMAT) plans depends on the planner's expertise.
- p-value p < 0.001
APA
Sasaki M, Nakaguchi Y, et al. (2025). Linear accelerator selection: impact on feasibility dose-volume histograms and practicality in dose reduction for organs at risk during prostate volumetric-modulated arc therapy.. Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology, 30(4), 462-473. https://doi.org/10.5603/rpor.106490
MLA
Sasaki M, et al.. "Linear accelerator selection: impact on feasibility dose-volume histograms and practicality in dose reduction for organs at risk during prostate volumetric-modulated arc therapy.." Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology, vol. 30, no. 4, 2025, pp. 462-473.
PMID
41195101 ↗
Abstract 한글 요약
[BACKGROUND] The quality of volumetric-modulated arc therapy (VMAT) plans depends on the planner's expertise. A feasibility dose-volume histogram (FDVH) may help reduce planning variability.
[MATERIALS AND METHODS] This study evaluated the impact of two linear accelerators - Halcyon and TrueBeam - on FDVH in prostate VMAT planning and their effectiveness in reducing doses to organs at risk (OARs). VMAT plans were generated for 30 patients with prostate cancer, with planning target volume excluding the rectum (PTV-R) and OAR contours created by three planners. An FDVH was created, and plans were classified as "difficult" (0 < F ≤ 0.1) based on OAR dose reduction.
[RESULTS] The D98% and D2% of PTV-R were analyzed, showing that TrueBeam had a higher mean dose at D98% and a lower mean dose at D2% compared to Halcyon, but these differences were not statistically significant (D98%: p = 0.123, D2%: p = 0.167). For the rectum, TrueBeam resulted in significantly lower doses for all dose constraints compared to Halcyon (p < 0.001). In the bladder, TrueBeam showed a significantly lower dose at V40Gy (p < 0.001). The upper limits of feasible F-values were 0.00-0.12 (TrueBeam) and 0.00-0.17 (Halcyon) for the rectum, and 0.01-0.20 (TrueBeam) and 0.00-0.20 (Halcyon) for the bladder, depending on dose parameters.
[CONCLUSIONS] These findings highlight that the choice of the linear accelerator significantly impacts OAR dose reduction. In prostate VMAT, TrueBeam demonstrated superior rectal and bladder dose reduction compared to Halcyon, underscoring the importance of selecting the appropriate device to optimize treatment planning and minimize variability.
[MATERIALS AND METHODS] This study evaluated the impact of two linear accelerators - Halcyon and TrueBeam - on FDVH in prostate VMAT planning and their effectiveness in reducing doses to organs at risk (OARs). VMAT plans were generated for 30 patients with prostate cancer, with planning target volume excluding the rectum (PTV-R) and OAR contours created by three planners. An FDVH was created, and plans were classified as "difficult" (0 < F ≤ 0.1) based on OAR dose reduction.
[RESULTS] The D98% and D2% of PTV-R were analyzed, showing that TrueBeam had a higher mean dose at D98% and a lower mean dose at D2% compared to Halcyon, but these differences were not statistically significant (D98%: p = 0.123, D2%: p = 0.167). For the rectum, TrueBeam resulted in significantly lower doses for all dose constraints compared to Halcyon (p < 0.001). In the bladder, TrueBeam showed a significantly lower dose at V40Gy (p < 0.001). The upper limits of feasible F-values were 0.00-0.12 (TrueBeam) and 0.00-0.17 (Halcyon) for the rectum, and 0.01-0.20 (TrueBeam) and 0.00-0.20 (Halcyon) for the bladder, depending on dose parameters.
[CONCLUSIONS] These findings highlight that the choice of the linear accelerator significantly impacts OAR dose reduction. In prostate VMAT, TrueBeam demonstrated superior rectal and bladder dose reduction compared to Halcyon, underscoring the importance of selecting the appropriate device to optimize treatment planning and minimize variability.
🏷️ 키워드 / MeSH 📖 같은 키워드 OA만
같은 제1저자의 인용 많은 논문 (1)
🏷️ 같은 키워드 · 무료전문 — 이 논문 MeSH/keyword 기반
- Prostate Cancer Care for Men with an Intellectual Disability: A Population-based Cohort Study of Symptoms, Diagnosis, Treatment, and Survival.
- Association between polygenic risk scores and cardiovascular events in prostate cancer patients receiving androgen deprivation therapy in Han Chinese.
- Diagnostic accuracy of Ga-PSMA PET/CT versus multiparametric MRI for preoperative pelvic invasion in the patients with prostate cancer.
- Comprehensive analysis of androgen receptor splice variant target gene expression in prostate cancer.
- Interleukin-11: A pivotal player and potential therapeutic target in prostate cancer.
- Comparative Detection Performance of PSMA and Non-PSMA PET Tracers in Recurrent and Primary Prostate Cancer: A Systematic Review and Network Meta-Analysis.