본문으로 건너뛰기
← 뒤로

Dosimetric Comparison of CyberKnife and Conventional Linac Prostate Stereotactic Body Radiation Therapy Plans: Analysis of the PACE-B Study.

4/5 보강
International journal of radiation oncology, biology, physics 📖 저널 OA 20.1% 2024: 1/2 OA 2025: 12/62 OA 2026: 24/121 OA 2024~2026 2026 Vol.125(1) p. 250-256 cited 8 OA RCR 3.14 Prostate Cancer Diagnosis and Treatm
TL;DR Although the CK-SBRT cohort showed lower urinary toxicity, the planned doses to urinary substructures were actually higher, likely due to heterogeneous dose planning.
Retraction 확인
출처
PubMed DOI OpenAlex Semantic 마지막 보강 2026-04-29

PICO 자동 추출 (휴리스틱, conf 3/4)

유사 논문
P · Population 대상 환자/모집단
414 patients who received SBRT, 169 (41%) were treated with CK-SBRT and 245 (59%) with CL-SBRT, with dosimetric parameters available for 94% of patients (390/414).
I · Intervention 중재 / 시술
SBRT, 169 (41%) were treated with CK-SBRT and 245 (59%) with CL-SBRT, with dosimetric parameters available for 94% of patients (390/414)
C · Comparison 대조 / 비교
추출되지 않음
O · Outcome 결과 / 결론
[CONCLUSIONS] Although the CK-SBRT cohort showed lower urinary toxicity, the planned doses to urinary substructures were actually higher, likely due to heterogeneous dose planning. Factors like intrafraction tracking or other confounding variables may explain the differences in toxicity outcomes between the treatment platforms.
연도별 인용 (2025–2026) · 합계 8
OpenAlex 토픽 · Prostate Cancer Diagnosis and Treatment Advanced Radiotherapy Techniques Radiation Dose and Imaging

Ratnakumaran R, Sasitharan A, Khan A, Mayet H, Mohajer J, Hinder V

📝 환자 설명용 한 줄

Although the CK-SBRT cohort showed lower urinary toxicity, the planned doses to urinary substructures were actually higher, likely due to heterogeneous dose planning.

🔬 핵심 임상 통계 (초록에서 자동 추출 — 원문 검증 권장)
  • p-value P = .02
  • p-value P < .0001

이 논문을 인용하기

↓ .bib ↓ .ris
APA Ragu Ratnakumaran, Archana Sasitharan, et al. (2026). Dosimetric Comparison of CyberKnife and Conventional Linac Prostate Stereotactic Body Radiation Therapy Plans: Analysis of the PACE-B Study.. International journal of radiation oncology, biology, physics, 125(1), 250-256. https://doi.org/10.1016/j.ijrobp.2025.01.014
MLA Ragu Ratnakumaran, et al.. "Dosimetric Comparison of CyberKnife and Conventional Linac Prostate Stereotactic Body Radiation Therapy Plans: Analysis of the PACE-B Study.." International journal of radiation oncology, biology, physics, vol. 125, no. 1, 2026, pp. 250-256.
PMID 39862896 ↗

Abstract

[PURPOSE] In the PACE-B study, a nonrandomized comparison of toxicity outcomes between stereotactic body radiation therapy (SBRT) platforms revealed fewer urinary side effects with CyberKnife (CK) compared with conventional linac (CL) SBRT. This analysis compares baseline characteristics and planning dosimetry between the CK-SBRT and CL-SBRT cohorts in PACE-B, aiming to provide insight into possible reasons for differing toxicity outcomes between the platforms.

[METHODS AND MATERIALS] Dosimetric parameters for the surrogate urethra (SU), contoured urethra, bladder, bladder trigone (BT), and rectum were extracted from available computed tomography planning scans of PACE-B SBRT patients. The SU and BT were retrospectively delineated. Dose levels analyzed included maximum point dose (Dmax), D2, D50, and D95, where D(n) represents the dose (Gy) to (n)% of the structure. Baseline characteristics and planning dosimetry between the CK-SBRT and CL-SBRT cohorts were compared using Mann-Whitney U tests, t tests, and χ tests.

[RESULTS] Of the 414 patients who received SBRT, 169 (41%) were treated with CK-SBRT and 245 (59%) with CL-SBRT, with dosimetric parameters available for 94% of patients (390/414). There was a nonstatistically significant trend toward more low-risk prostate cancer in the CK-SBRT cohort (12% vs 6% P = .02 [nonsignificant]). Margins were similar between platforms, except posteriorly, where CK-SBRT had smaller margins. CK-SBRT plans had significantly higher median SU Dmax (45.9 Gy vs 42.8 Gy, P < .0001), D2%, and D50% compared with CL-SBRT plans. Additionally, CK-SBRT plans had significantly higher median BT Dmax (43.4 Gy vs 41.6 Gy, P < .0001), D2%, and D95%, as well as higher median bladder Dmax, D50%, and D95%. CK-SBRT plans had lower median rectal D2% (35.5 Gy vs 36.0 Gy, P < .0001) but higher rectal D50% and D95%.

[CONCLUSIONS] Although the CK-SBRT cohort showed lower urinary toxicity, the planned doses to urinary substructures were actually higher, likely due to heterogeneous dose planning. Factors like intrafraction tracking or other confounding variables may explain the differences in toxicity outcomes between the treatment platforms.

🏷️ 키워드 / MeSH 📖 같은 키워드 OA만

같은 제1저자의 인용 많은 논문 (1)

🏷️ 같은 키워드 · 무료전문 — 이 논문 MeSH/keyword 기반

🔓 OA PDF 열기