A Novel Technique of Overtube-assisted Ultrathin Endoscopic Biliary Drainage Using Multi-Hole Self-Expandable Metal Stents: A Case Report.
증례보고
2/5 보강
TL;DR
A 67‐year‐old woman developed obstructive jaundice due to hilar biliary stricture secondary to peritoneal dissemination following colorectal cancer surgery and a novel overtube‐assisted ultrathin endoscope technique was employed, allowing continuation of systemic chemotherapy.
PICO 자동 추출 (휴리스틱, conf 2/4)
유사 논문P · Population 대상 환자/모집단
환자: altered anatomy or tumor-related distortion
I · Intervention 중재 / 시술
추출되지 않음
C · Comparison 대조 / 비교
추출되지 않음
O · Outcome 결과 / 결론
This case demonstrates a novel overtube-assisted ultrathin endoscope technique. The combination of thin delivery systems and an overtube modification may provide a valuable alternative when both conventional ERCP and EUS-BD are not feasible.
OpenAlex 토픽 ·
Gallbladder and Bile Duct Disorders
Esophageal and GI Pathology
Pancreatic and Hepatic Oncology Research
A 67‐year‐old woman developed obstructive jaundice due to hilar biliary stricture secondary to peritoneal dissemination following colorectal cancer surgery and a novel overtube‐assisted ultrathin endo
APA
Akinobu Koiwai, Morihisa Hirota, et al. (2026). A Novel Technique of Overtube-assisted Ultrathin Endoscopic Biliary Drainage Using Multi-Hole Self-Expandable Metal Stents: A Case Report.. DEN open, 6(1), e70253. https://doi.org/10.1002/deo2.70253
MLA
Akinobu Koiwai, et al.. "A Novel Technique of Overtube-assisted Ultrathin Endoscopic Biliary Drainage Using Multi-Hole Self-Expandable Metal Stents: A Case Report.." DEN open, vol. 6, no. 1, 2026, pp. e70253.
PMID
41311707 ↗
Abstract 한글 요약
Endoscopic retrograde cholangiopancreatography (ERCP) is the standard procedure for biliary drainage; however, access can be challenging in patients with altered anatomy or tumor-related distortion. Endoscopic ultrasound-guided biliary drainage (EUS-BD) is a common alternative, yet it is not always feasible, particularly in patients with prior hepatic resection or severe gastrointestinal deformation. A 67-year-old woman developed obstructive jaundice due to hilar biliary stricture secondary to peritoneal dissemination following colorectal cancer surgery. Initial ERCP achieved side-by-side placement of multi-hole self-expandable metal stents (MHSEMSs), resulting in effective drainage. At recurrence of cholangitis, repeat ERCP failed because of anatomical distortion, and EUS-BD was not feasible due to the patient's prior left hepatectomy. We therefore employed a novel technique: a double-balloon enteroscope overtube was advanced to the duodenum, and a side hole was created 10 cm distal to the insertion port. An ultrathin endoscope was inserted through this side hole, retroflexed in the duodenum, and successfully accessed the papilla. The previously placed MHSEMSs were removed, and new MHSEMSs were deployed using a stent-in-stent method. The patient's cholangitis and associated liver abscesses improved, allowing continuation of systemic chemotherapy. This case demonstrates a novel overtube-assisted ultrathin endoscope technique. The combination of thin delivery systems and an overtube modification may provide a valuable alternative when both conventional ERCP and EUS-BD are not feasible.
🏷️ 키워드 / MeSH 📖 같은 키워드 OA만
📖 전문 본문 읽기 PMC JATS · ~16 KB · 영문
Introduction
1
Introduction
Endoscopic retrograde cholangiopancreatography (ERCP) is the gold standard for biliary drainage in patients with malignant biliary obstruction. In most cases, standard duodenoscope access to the duodenal papilla is feasible. However, prior surgery, adhesions, or tumor‐related distortion may impede scope advancement. In such cases, endoscopic ultrasound‐guided biliary drainage (EUS‐BD) has emerged as a reliable alternative [1, 2]. Nevertheless, specific situations, including prior hepatectomy or the absence of suitable puncture routes, may preclude EUS‐BD. In such cases, percutaneous transhepatic biliary drainage (PTBD) remains the last resort but is invasive and often causes discomfort from external drainage. We present a unique case in which ultrathin endoscopy was combined with a double‐balloon enteroscope (DBE) overtube modified with a side hole, representing, to our knowledge, the first report of overtube‐assisted ultrathin endoscope ERCP with multi‐hole self‐expandable metal stents (MHSEMSs).
Introduction
Endoscopic retrograde cholangiopancreatography (ERCP) is the gold standard for biliary drainage in patients with malignant biliary obstruction. In most cases, standard duodenoscope access to the duodenal papilla is feasible. However, prior surgery, adhesions, or tumor‐related distortion may impede scope advancement. In such cases, endoscopic ultrasound‐guided biliary drainage (EUS‐BD) has emerged as a reliable alternative [1, 2]. Nevertheless, specific situations, including prior hepatectomy or the absence of suitable puncture routes, may preclude EUS‐BD. In such cases, percutaneous transhepatic biliary drainage (PTBD) remains the last resort but is invasive and often causes discomfort from external drainage. We present a unique case in which ultrathin endoscopy was combined with a double‐balloon enteroscope (DBE) overtube modified with a side hole, representing, to our knowledge, the first report of overtube‐assisted ultrathin endoscope ERCP with multi‐hole self‐expandable metal stents (MHSEMSs).
Case Report
2
Case Report
A 67‐year‐old woman with a history of rectal cancer underwent laparoscopic low anterior resection, followed by left hepatectomy for liver metastasis. She had been receiving systemic chemotherapy. During treatment, she developed perihilar biliary obstruction (Bismuth II) with obstructive jaundice and was referred to our department. Contrast‐enhanced computed tomography (CECT) and magnetic resonance cholangiopancreatography (MRCP) revealed intrahepatic bile duct dilatation caused by peritoneal dissemination (Figure 1a), and gastric deformation, with the distal stomach adherent to the remnant liver (Figure 1b).
First intervention: Because of gastric deformation, insertion of a standard duodenoscope (TJF‐Q290V; Olympus, Tokyo, Japan) was unsuccessful. A forward‐viewing scope (GIF‐EZ1500; Olympus) was used to insert a 0.045‐inch guidewire (Denis, Cardinal Health) into the distal duodenum (Figure 1c), and the duodenoscope was advanced over the wire. Biliary cannulation was achieved, and two MHSEMSs (HANAROSTENT Biliary Multi Hole Benefit; Boston Scientific, MA, USA, Figure S1a) were placed side‐by‐side across the papilla (right anterior segmental bile duct: 6 mm×8 cm, right posterior: 6 mm×10 cm) (Figure 1d), resulting in effective drainage.
Second intervention: Several months later, she developed cholangitis due to stent occlusion. Repeated ERCP using guidewire‐assisted and balloon‐anchor techniques (Figure 2a) failed. Because of the prior left hepatectomy, EUS‐hepaticogastrostomy (HGS) was not possible. An ultrathin endoscope (GIF‐1200N; Olympus, Figure S1b) was advanced into the second portion of the duodenum, retroflexed to visualize the papilla (Figure 2b,c), and a 5Fr‐endoscopic retrograde biliary drainage (ERBD) tube (10cm; Medi‐Globe GmbH, Rohrdorf, Germany) was placed through the MHSEMS (Figure 2d). However, cholangitis recurred shortly, complicated by multiple hepatic abscesses (Figure S1c).
Third intervention with overtube modification: Subsequent attempts to reinsert the ultrathin endoscope failed due to worsening adhesions (Figure S1d). A forward‐viewing scope (GIF‐EZ1500, Olympus/ EI‐580BT; FUJIFILM, Tokyo, Japan) could reach the duodenum, but retroflexion caused resistance and was deemed unsafe because of perforation risk. We therefore advanced a DBE overtube (TS‐13101; FUJIFILM) to the duodenum and withdrew the scope (Figure 3a). However, due to the length of the overtube, conventional insertion of the ultrathin endoscope through the proximal opening did not provide sufficient length to achieve retroflexion in the duodenum. A side hole was therefore created in the overtube approximately 10 cm distal to the insertion port, enabling passage of an ultrathin endoscope (Figure 3b). Through this side hole, the ultrathin endoscope was advanced into the duodenum, retroflexed, and successfully visualized the papilla (Figure 3c). After exchanging the scope for an EI‐580BT, the previously placed MHSEMSs were removed in a downward viewing position through the scope using a snare (Snare Master Plus; Olympus). The ultrathin endoscope was reinserted, and cholangiography confirmed a hilar stricture (Figure 4a). Although side‐by‐side stenting was planned, the MHSEMS delivery system could not pass in parallel. Instead, a partial stent‐in‐stent technique was performed, successfully deploying MHSEMSs into the right anterior (6 mm×10 cm) and posterior (6 mm×12 cm) segmental bile ducts (Figure 4b–d). The patient's cholangitis and hepatic abscess improved, allowing resumption of chemotherapy.
Case Report
A 67‐year‐old woman with a history of rectal cancer underwent laparoscopic low anterior resection, followed by left hepatectomy for liver metastasis. She had been receiving systemic chemotherapy. During treatment, she developed perihilar biliary obstruction (Bismuth II) with obstructive jaundice and was referred to our department. Contrast‐enhanced computed tomography (CECT) and magnetic resonance cholangiopancreatography (MRCP) revealed intrahepatic bile duct dilatation caused by peritoneal dissemination (Figure 1a), and gastric deformation, with the distal stomach adherent to the remnant liver (Figure 1b).
First intervention: Because of gastric deformation, insertion of a standard duodenoscope (TJF‐Q290V; Olympus, Tokyo, Japan) was unsuccessful. A forward‐viewing scope (GIF‐EZ1500; Olympus) was used to insert a 0.045‐inch guidewire (Denis, Cardinal Health) into the distal duodenum (Figure 1c), and the duodenoscope was advanced over the wire. Biliary cannulation was achieved, and two MHSEMSs (HANAROSTENT Biliary Multi Hole Benefit; Boston Scientific, MA, USA, Figure S1a) were placed side‐by‐side across the papilla (right anterior segmental bile duct: 6 mm×8 cm, right posterior: 6 mm×10 cm) (Figure 1d), resulting in effective drainage.
Second intervention: Several months later, she developed cholangitis due to stent occlusion. Repeated ERCP using guidewire‐assisted and balloon‐anchor techniques (Figure 2a) failed. Because of the prior left hepatectomy, EUS‐hepaticogastrostomy (HGS) was not possible. An ultrathin endoscope (GIF‐1200N; Olympus, Figure S1b) was advanced into the second portion of the duodenum, retroflexed to visualize the papilla (Figure 2b,c), and a 5Fr‐endoscopic retrograde biliary drainage (ERBD) tube (10cm; Medi‐Globe GmbH, Rohrdorf, Germany) was placed through the MHSEMS (Figure 2d). However, cholangitis recurred shortly, complicated by multiple hepatic abscesses (Figure S1c).
Third intervention with overtube modification: Subsequent attempts to reinsert the ultrathin endoscope failed due to worsening adhesions (Figure S1d). A forward‐viewing scope (GIF‐EZ1500, Olympus/ EI‐580BT; FUJIFILM, Tokyo, Japan) could reach the duodenum, but retroflexion caused resistance and was deemed unsafe because of perforation risk. We therefore advanced a DBE overtube (TS‐13101; FUJIFILM) to the duodenum and withdrew the scope (Figure 3a). However, due to the length of the overtube, conventional insertion of the ultrathin endoscope through the proximal opening did not provide sufficient length to achieve retroflexion in the duodenum. A side hole was therefore created in the overtube approximately 10 cm distal to the insertion port, enabling passage of an ultrathin endoscope (Figure 3b). Through this side hole, the ultrathin endoscope was advanced into the duodenum, retroflexed, and successfully visualized the papilla (Figure 3c). After exchanging the scope for an EI‐580BT, the previously placed MHSEMSs were removed in a downward viewing position through the scope using a snare (Snare Master Plus; Olympus). The ultrathin endoscope was reinserted, and cholangiography confirmed a hilar stricture (Figure 4a). Although side‐by‐side stenting was planned, the MHSEMS delivery system could not pass in parallel. Instead, a partial stent‐in‐stent technique was performed, successfully deploying MHSEMSs into the right anterior (6 mm×10 cm) and posterior (6 mm×12 cm) segmental bile ducts (Figure 4b–d). The patient's cholangitis and hepatic abscess improved, allowing resumption of chemotherapy.
Discussion
3
Discussion
This case illustrates several important points. Conventional ERCP can fail in patients with severe anatomical changes due to prior surgery or tumor spread. Techniques such as guidewire assistance or balloon anchoring [3, 4] may sometimes enable access, but these strategies are not universally successful. In our patient, such approaches allowed the initial metal stent placement but became ineffective as peritoneal dissemination and adhesions progressed. Although EUS‐BD is a reliable alternative [2, 5], some conditions preclude its use. In particular, after left hepatectomy, the puncture route for hepaticogastrostomy may not be available. Even when technically feasible, EUS‐BD carries risks of bile leakage (peritonitis) [6, 7] or stent migration [1], which may be critical in fragile oncology patients. Thus, reliance solely on EUS‐BD is not always appropriate, and other strategies should be considered. We demonstrated a novel solution using a DBE overtube modified with a side hole. The overtube's original length prevented retroflexion of the ultrathin endoscope. By creating a side hole approximately 10 cm distal to the insertion port, we secured a working length that allowed stable retroflexion in the duodenum. This modification enabled safe scope maneuverability and direct access to the papilla. To our knowledge, no previous reports have described this method. The development of MHSEMS with a thin 5.9‐Fr delivery system enabled compatibility with the 2.2‐mm channel of the ultrathin endoscope, allowing successful stent deployment. Previously, SEMSs required larger channels (>3.2 mm), limiting ultrathin endoscopes. This advance expanded their role from diagnostic to therapeutic use. In our case, the side holes of the MHSEMS facilitated a partial stent‐in‐stent technique, allowing deployment of an additional stent through the previously placed device, contributing to the success of re‐intervention. This approach offered an alternative to PTBD, which is invasive and negatively impacts quality of life. Oncology patients in particular may benefit from internal drainage, which reduces infection risk and allows continuation of chemotherapy.
Beyond this individual case, several implications deserve mention. The combination of ultrathin endoscopes and thin delivery systems suggests new possibilities for therapeutic interventions in anatomically difficult cases. The adaptation of the DBE overtube demonstrates how existing devices can be modified to extend endoscopic options. Previous reports have demonstrated overtube (ST‐CB1; Olympus)‐assisted advancement of a side‐viewing duodenoscope in patients with gastric deformity or cascade stomach [8, 9]. While these techniques are useful, they have procedural limitations. The duodenoscope must first be inserted into the overtube without a top hood, and the hood is mounted afterward before advancing into the patient. Once the overtube remains in place, the duodenoscope cannot be reinserted, restricting repeated insertions or scope exchanges. In contrast, overtube insertion under direct visualization of flexures and strictures with a forward‐viewing endoscope ensures safer and more controlled advancement, offering a distinct procedural advantage. Our method thus provides a practical and safer alternative, particularly in institutions equipped only with DBE systems. However, the use of a side‐viewing duodenoscope allows greater familiarity and broader therapeutic options, whereas procedures using an ultrathin endoscope remain technically challenging due to limited channel size and maneuverability. Therefore, treatment strategies should be selected according to individual case characteristics.
The safety of this approach must also be considered. Creating a side hole may compromise overtube integrity, and repeated retroflexion carries a risk of perforation. Although Hirata et al. have described the safety of retroflex position using forward‐viewing endoscopes [10], it is crucial to select treatment strategies with careful consideration of potential risks in each individual case. This method should be reserved for expert centers with surgical backup. By combining an overtube modification, an ultrathin endoscope, and slim MHSEMS delivery systems, we achieved effective biliary drainage when ERCP and EUS‐BD were not feasible. We report the first case of biliary drainage using a novel overtube‐assisted ultrathin endoscopic technique with MHSEMS deployment. This novel overtube‐assisted ultrathin endoscopic technique may expand therapeutic options for selected patients with challenging biliary obstruction.
Discussion
This case illustrates several important points. Conventional ERCP can fail in patients with severe anatomical changes due to prior surgery or tumor spread. Techniques such as guidewire assistance or balloon anchoring [3, 4] may sometimes enable access, but these strategies are not universally successful. In our patient, such approaches allowed the initial metal stent placement but became ineffective as peritoneal dissemination and adhesions progressed. Although EUS‐BD is a reliable alternative [2, 5], some conditions preclude its use. In particular, after left hepatectomy, the puncture route for hepaticogastrostomy may not be available. Even when technically feasible, EUS‐BD carries risks of bile leakage (peritonitis) [6, 7] or stent migration [1], which may be critical in fragile oncology patients. Thus, reliance solely on EUS‐BD is not always appropriate, and other strategies should be considered. We demonstrated a novel solution using a DBE overtube modified with a side hole. The overtube's original length prevented retroflexion of the ultrathin endoscope. By creating a side hole approximately 10 cm distal to the insertion port, we secured a working length that allowed stable retroflexion in the duodenum. This modification enabled safe scope maneuverability and direct access to the papilla. To our knowledge, no previous reports have described this method. The development of MHSEMS with a thin 5.9‐Fr delivery system enabled compatibility with the 2.2‐mm channel of the ultrathin endoscope, allowing successful stent deployment. Previously, SEMSs required larger channels (>3.2 mm), limiting ultrathin endoscopes. This advance expanded their role from diagnostic to therapeutic use. In our case, the side holes of the MHSEMS facilitated a partial stent‐in‐stent technique, allowing deployment of an additional stent through the previously placed device, contributing to the success of re‐intervention. This approach offered an alternative to PTBD, which is invasive and negatively impacts quality of life. Oncology patients in particular may benefit from internal drainage, which reduces infection risk and allows continuation of chemotherapy.
Beyond this individual case, several implications deserve mention. The combination of ultrathin endoscopes and thin delivery systems suggests new possibilities for therapeutic interventions in anatomically difficult cases. The adaptation of the DBE overtube demonstrates how existing devices can be modified to extend endoscopic options. Previous reports have demonstrated overtube (ST‐CB1; Olympus)‐assisted advancement of a side‐viewing duodenoscope in patients with gastric deformity or cascade stomach [8, 9]. While these techniques are useful, they have procedural limitations. The duodenoscope must first be inserted into the overtube without a top hood, and the hood is mounted afterward before advancing into the patient. Once the overtube remains in place, the duodenoscope cannot be reinserted, restricting repeated insertions or scope exchanges. In contrast, overtube insertion under direct visualization of flexures and strictures with a forward‐viewing endoscope ensures safer and more controlled advancement, offering a distinct procedural advantage. Our method thus provides a practical and safer alternative, particularly in institutions equipped only with DBE systems. However, the use of a side‐viewing duodenoscope allows greater familiarity and broader therapeutic options, whereas procedures using an ultrathin endoscope remain technically challenging due to limited channel size and maneuverability. Therefore, treatment strategies should be selected according to individual case characteristics.
The safety of this approach must also be considered. Creating a side hole may compromise overtube integrity, and repeated retroflexion carries a risk of perforation. Although Hirata et al. have described the safety of retroflex position using forward‐viewing endoscopes [10], it is crucial to select treatment strategies with careful consideration of potential risks in each individual case. This method should be reserved for expert centers with surgical backup. By combining an overtube modification, an ultrathin endoscope, and slim MHSEMS delivery systems, we achieved effective biliary drainage when ERCP and EUS‐BD were not feasible. We report the first case of biliary drainage using a novel overtube‐assisted ultrathin endoscopic technique with MHSEMS deployment. This novel overtube‐assisted ultrathin endoscopic technique may expand therapeutic options for selected patients with challenging biliary obstruction.
Author Contributions
Author Contributions
Akinobu Koiwai: prepared the first draft of the manuscript. Akinobu Koiwai, Morihisa Hirota, Kei Ishikawa, Chihiro Yunomura, Takuro Nakaya, Yuki Miyashita, and Nana Inomata: managed the patient. Morihisa Hirota and Kennichi Satoh: revised the manuscript. All authors approved the final version of the manuscript.
Akinobu Koiwai: prepared the first draft of the manuscript. Akinobu Koiwai, Morihisa Hirota, Kei Ishikawa, Chihiro Yunomura, Takuro Nakaya, Yuki Miyashita, and Nana Inomata: managed the patient. Morihisa Hirota and Kennichi Satoh: revised the manuscript. All authors approved the final version of the manuscript.
Funding
Funding
The authors received no specific funding for this work.
The authors received no specific funding for this work.
Conflicts of Interest
Conflicts of Interest
The authors declare no conflicts of interest.
The authors declare no conflicts of interest.
Supporting information
Supporting information
Supplementary Figure 1: (a) Structure of the MHSEMS (HANAROSTENT Biliary Multi Hole Benefit; Boston Scientific, MA, USA). The MHSEMS is a fully covered metallic stent designed with multiple longitudinally aligned side holes arranged in alternating rows around the circumference of the stent. These side holes maintain bile flow through collateral channels, even when the main lumen is partially occluded, and also facilitate guidewire passage during reintervention. MHSEMS: multi‐hole self‐expandable metal stent. (b) Ultrathin endoscope (GIF‐1200N; Olympus, Tokyo, Japan). The GIF‐1200N is an ultrathin endoscope with an outer diameter of 5.4 mm and a working channel of 2.2 mm, originally designed for trans‐nasal endoscopy. (c) CECT revealed multiple small hepatic abscesses, presumed to be due to cholangitis. CECT: contrast‐enhanced computed tomography. Fluoroscopic image showing failed advancement of the ultrathin endoscope into the second portion of the duodenum, despite guidewire‐assisted insertion attempts.
Supplementary Figure 1: (a) Structure of the MHSEMS (HANAROSTENT Biliary Multi Hole Benefit; Boston Scientific, MA, USA). The MHSEMS is a fully covered metallic stent designed with multiple longitudinally aligned side holes arranged in alternating rows around the circumference of the stent. These side holes maintain bile flow through collateral channels, even when the main lumen is partially occluded, and also facilitate guidewire passage during reintervention. MHSEMS: multi‐hole self‐expandable metal stent. (b) Ultrathin endoscope (GIF‐1200N; Olympus, Tokyo, Japan). The GIF‐1200N is an ultrathin endoscope with an outer diameter of 5.4 mm and a working channel of 2.2 mm, originally designed for trans‐nasal endoscopy. (c) CECT revealed multiple small hepatic abscesses, presumed to be due to cholangitis. CECT: contrast‐enhanced computed tomography. Fluoroscopic image showing failed advancement of the ultrathin endoscope into the second portion of the duodenum, despite guidewire‐assisted insertion attempts.
출처: PubMed Central (JATS). 라이선스는 원 publisher 정책을 따릅니다 — 인용 시 원문을 표기해 주세요.
🏷️ 같은 키워드 · 무료전문 — 이 논문 MeSH/keyword 기반
- Groove area involvement predicts post-ERCP pancreatitis after 8-mm fully-covered metal stent placement in resectable pancreatic cancer.
- Impact of Peri-Procedural Antibiotics on Post-ERCP Infectious Adverse Events With Distal Malignant Biliary Obstruction.
- Preoperative Surgical or Endoscopic Bile Duct Drainage in Pancreatic Cancer.
- Changing the Flow: How EUS-Guided Drainage is Reshaping the Management of Distal Malignant Biliary Obstruction.
- Effects of Pancreatic Duct Stenting on Nutrition and Pancreatic Function in Unresectable Pancreatic Cancer: A Pilot Study.
- Partially covered or uncovered metal stent efficacy in malignant unresectable distal biliary obstruction (METARSI): Randomized multicenter trial.