본문으로 건너뛰기
← 뒤로

Artificial intelligence-assisted automated measurement of maximum aortic diameter in the Korean national lung cancer screening CT program.

1/5 보강
The British journal of radiology 📖 저널 OA 31% 2021: 1/1 OA 2023: 2/4 OA 2024: 3/3 OA 2025: 8/14 OA 2026: 7/45 OA 2021~2026 2026 Vol.99(1179) p. 550-560
Retraction 확인
출처

PICO 자동 추출 (휴리스틱, conf 2/4)

유사 논문
P · Population 대상 환자/모집단
1204 patients (99.
I · Intervention 중재 / 시술
추출되지 않음
C · Comparison 대조 / 비교
추출되지 않음
O · Outcome 결과 / 결론
Aortic dilation distribution may serve as a reference in LDCT LCS, and its association with CAC highlights the clinical importance of incorporating MADs into patient management. [ADVANCES IN KNOWLEDGE] Validated AI software enables reliable MAD assessment; reported aortic dilation prevalence offers valuable reference data for LDCT LCS.

Park C, Lee HJ, Jeong WG

📝 환자 설명용 한 줄

[OBJECTIVES] Management guidelines for incidental aortic dilation detected on low-dose chest computed tomography (LDCT) lung cancer screening (LCS) are lacking.

🔬 핵심 임상 통계 (초록에서 자동 추출 — 원문 검증 권장)
  • p-value P ≤ .001

이 논문을 인용하기

↓ .bib ↓ .ris
APA Park C, Lee HJ, Jeong WG (2026). Artificial intelligence-assisted automated measurement of maximum aortic diameter in the Korean national lung cancer screening CT program.. The British journal of radiology, 99(1179), 550-560. https://doi.org/10.1093/bjr/tqaf316
MLA Park C, et al.. "Artificial intelligence-assisted automated measurement of maximum aortic diameter in the Korean national lung cancer screening CT program.." The British journal of radiology, vol. 99, no. 1179, 2026, pp. 550-560.
PMID 41428449 ↗
DOI 10.1093/bjr/tqaf316

Abstract

[OBJECTIVES] Management guidelines for incidental aortic dilation detected on low-dose chest computed tomography (LDCT) lung cancer screening (LCS) are lacking. Therefore, this study aims to validate artificial intelligence (AI) software for automated aortic measurements and assess aortic dilation distribution in screening participants.

[METHODS] Baseline LDCT scans from 2 tertiary centres (April 2017 to December 2023) were reviewed. In 100 randomly selected cases, radiologist- and AI-measured maximum aortic diameters (MADs) were compared at the ascending thoracic aorta (ATA), aortic arch (AACH), descending thoracic aorta (DTA), and abdominal aorta (AA). AI then analysed all scans, and coronary artery calcification (CAC) was assessed using the Agatston method to evaluate correlations with MADs.

[RESULTS] Overall, 1204 patients (99.2% men; mean age ± SD: 62.7 ± 5.4 years) were included. Intraclass correlation coefficients between radiologists and AI were 0.950, 0.758, 0.933, and 0.931 for ATA, AACH, DTA, and AA, respectively. Mean maximum diameters were: ATA, 38.7 ± 3.7 mm (33.4% ≥ 40 mm, 18.5% ≥ 42 mm, and 5.6% ≥ 45 mm); AACH, 37.3 ± 3.3 mm; DTA, 29.4 ± 2.9 mm; and AA, 26.3 ± 2.3 mm. MADs significantly correlated with CAC severity (P ≤ .001).

[CONCLUSIONS] AI software reliably measures MADs. Aortic dilation distribution may serve as a reference in LDCT LCS, and its association with CAC highlights the clinical importance of incorporating MADs into patient management.

[ADVANCES IN KNOWLEDGE] Validated AI software enables reliable MAD assessment; reported aortic dilation prevalence offers valuable reference data for LDCT LCS.

🏷️ 키워드 / MeSH 📖 같은 키워드 OA만

같은 제1저자의 인용 많은 논문 (4)

🏷️ 같은 키워드 · 무료전문 — 이 논문 MeSH/keyword 기반