본문으로 건너뛰기
← 뒤로

Single-Electrode High-Throughput 12-Well Array Electrochemiluminescence Imaging Sensor for Portable Parallel Dual-Color Analysis of Dual Breast Cancer Susceptibility Genes.

1/5 보강
Analytical chemistry 📖 저널 OA 12.8% 2021: 0/1 OA 2022: 0/2 OA 2023: 0/3 OA 2024: 1/9 OA 2025: 6/55 OA 2026: 12/79 OA 2021~2026 2026 Vol.98(7) p. 5593-5602
Retraction 확인
출처

Dong Y, Fu B, Wu H, Jie G

📝 환자 설명용 한 줄

Rapid, high-throughput analysis of breast cancer susceptibility genes is essential in a clinical diagnosis.

이 논문을 인용하기

↓ .bib ↓ .ris
APA Dong Y, Fu B, et al. (2026). Single-Electrode High-Throughput 12-Well Array Electrochemiluminescence Imaging Sensor for Portable Parallel Dual-Color Analysis of Dual Breast Cancer Susceptibility Genes.. Analytical chemistry, 98(7), 5593-5602. https://doi.org/10.1021/acs.analchem.5c07223
MLA Dong Y, et al.. "Single-Electrode High-Throughput 12-Well Array Electrochemiluminescence Imaging Sensor for Portable Parallel Dual-Color Analysis of Dual Breast Cancer Susceptibility Genes.." Analytical chemistry, vol. 98, no. 7, 2026, pp. 5593-5602.
PMID 41668435 ↗

Abstract

Rapid, high-throughput analysis of breast cancer susceptibility genes is essential in a clinical diagnosis. Herein, we designed a 12-well single-electrode electrochemiluminescence (ECL) imaging array biosensor for parallel high-throughput dual-color analysis of dual cancer genes (BRCA1 and BRCA2). Two newly explored luminophores, the Eu-luminol complex and Ru/Zn MOF with blue and orange-red high-intensity ECL emission, were introduced to the array, achieving high-resolution color-distinguishing ECL imaging of double targets. This work innovatively changed the fabrication technology of single-electrode arrays by replacing poly(dimethylsiloxane) (PDMS) with polypropylene tubes. This reformation enabled independent construction of 12 microcells, thus enhancing their stability and reducing production costs. The 12 microcells on the ITO electrode drastically reduce the target detection time and streamline the procedure compared to traditional three-electrode systems. The visual ECL signals were conveniently captured by using a smartphone, yielding readily distinguishable orange-red and blue images. The target-induced walker amplification technology is utilized to integrate the quenching probes Au@Ag NPs and CuS@Au NPs into the single electrode, enabling simultaneous ECL imaging of 12 microwells for detection of multiple targets. Owing to multiple outstanding advantages of high-throughput, fast speed, and convenience, the developed 12-well single-electrode dual-color ECL imaging biosensor holds considerable promise for broad applications in biological and environmental monitoring.

🏷️ 키워드 / MeSH 📖 같은 키워드 OA만

같은 제1저자의 인용 많은 논문 (5)

🏷️ 같은 키워드 · 무료전문 — 이 논문 MeSH/keyword 기반