How Camera-to-Subject Distance and Height Affect Breast Measurement and Follow-Up Assessment in Plastic Surgery.
4/5 보강
TL;DR
The effects of camera-to-subject distances and camera height on breast measurement parameters are investigated to understand the trend of breast deformation and provide guidance for the accurate evaluation of planar follow-up.
OpenAlex 토픽 ·
Digital Imaging in Medicine
Breast Implant and Reconstruction
Anatomy and Medical Technology
ℹ️ 이 논문은 무료 전문이 아직 없습니다. 코퍼스 전체의 44.0%는 무료 가능 (통계 →) · 🏥 기관 EZproxy로 시도
【연구 목적】 2차원 유방 사진 촬영 시 화질 편향을 유발하는 주요 변수인 카메라와 피사체 간 거리 및 촬영 높이가 유방 측정 파라미터에 미치는 영향을 규명하여, 정확한 평면 추적 평가를 위한 표준화 가이드라인을 제시하는 것이 연구의 핵심 목표이다.
- p-value p < 0.01
- p-value p < 0.05
APA
Jiangmiao Xie, Wenchao Zhang, et al. (2024). How Camera-to-Subject Distance and Height Affect Breast Measurement and Follow-Up Assessment in Plastic Surgery.. Aesthetic plastic surgery, 48(7), 1487-1499. https://doi.org/10.1007/s00266-023-03510-z
MLA
Jiangmiao Xie, et al.. "How Camera-to-Subject Distance and Height Affect Breast Measurement and Follow-Up Assessment in Plastic Surgery.." Aesthetic plastic surgery, vol. 48, no. 7, 2024, pp. 1487-1499.
PMID
37488314 ↗
Abstract 한글 요약
[BACKGROUND] Due to several factors that affect photograph quality, bias is inevitably present in two-dimensional (2D) breast photography. The principal variables affecting image performance at a fixed focus length are the distance between the camera and the subjects and the photography angles.
[OBJECTIVE] This study aimed to investigate the effects of camera-to-subject distances and camera height on breast measurement parameters to understand the trend of breast deformation and provide guidance for the accurate evaluation of planar follow-up.
[METHODS] We enlisted 16 volunteers with various breast cup sizes (A-D). Frontal and lateral photos were obtained with a steady focus of 50 mm at distances between 1.10 m and 2.20 m and at heights between 30 cm above the nipple and 30 cm below the nipple at intervals of 10 cm. Two researchers independently evaluated each volunteer's breast aesthetic parameters, including 11 linear parameters, 3 area parameters, and 3 ratio parameters, using Vernier calipers and Photoshop.
[RESULTS] The correlation coefficient of the two investigators ranged from 0.922 to 0.999. The results measured by Photoshop were 29.67 ± 5.23% greater than those of the Vernier caliper (p < 0.01). In contrast to ratio parameters, which showed no significant changes in each distance group (p = 1.00), linear parameters and area parameters significantly increased as object distance decreased (p < 0.05). The lower pole of the breast grew wider and flatter and occupied a larger proportion of the breast as height declined.
[CONCLUSION] Camera-to-subject distances of 1.5-1.7 m are recommended for stabilized and uniform breast photography. Varying shooting height affects breast distortion. Quantifying the relationship between photographic conditions and breast morphology enables plastic surgeons to conduct more comprehensive and accurate assessments.
[LEVEL OF EVIDENCE IV] This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266. Bullet point list: 1. The breast morphology will get more distortion with a smaller camera-to-subject distance. 2. Camera-to-subject distances of 1.5~1.7m are recommended for stabilized and uniform breast photography. 3. Height rather than distance affects the breast proportion.
[OBJECTIVE] This study aimed to investigate the effects of camera-to-subject distances and camera height on breast measurement parameters to understand the trend of breast deformation and provide guidance for the accurate evaluation of planar follow-up.
[METHODS] We enlisted 16 volunteers with various breast cup sizes (A-D). Frontal and lateral photos were obtained with a steady focus of 50 mm at distances between 1.10 m and 2.20 m and at heights between 30 cm above the nipple and 30 cm below the nipple at intervals of 10 cm. Two researchers independently evaluated each volunteer's breast aesthetic parameters, including 11 linear parameters, 3 area parameters, and 3 ratio parameters, using Vernier calipers and Photoshop.
[RESULTS] The correlation coefficient of the two investigators ranged from 0.922 to 0.999. The results measured by Photoshop were 29.67 ± 5.23% greater than those of the Vernier caliper (p < 0.01). In contrast to ratio parameters, which showed no significant changes in each distance group (p = 1.00), linear parameters and area parameters significantly increased as object distance decreased (p < 0.05). The lower pole of the breast grew wider and flatter and occupied a larger proportion of the breast as height declined.
[CONCLUSION] Camera-to-subject distances of 1.5-1.7 m are recommended for stabilized and uniform breast photography. Varying shooting height affects breast distortion. Quantifying the relationship between photographic conditions and breast morphology enables plastic surgeons to conduct more comprehensive and accurate assessments.
[LEVEL OF EVIDENCE IV] This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266. Bullet point list: 1. The breast morphology will get more distortion with a smaller camera-to-subject distance. 2. Camera-to-subject distances of 1.5~1.7m are recommended for stabilized and uniform breast photography. 3. Height rather than distance affects the breast proportion.
【연구 목적】
2차원 유방 사진 촬영 시 화질 편향을 유발하는 주요 변수인 카메라와 피사체 간 거리 및 촬영 높이가 유방 측정 파라미터에 미치는 영향을 규명하여, 정확한 평면 추적 평가를 위한 표준화 가이드라인을 제시하는 것이 연구의 핵심 목표이다.
【방법】
A-D컵의 다양한 유방 크기를 가진 16명의 자원자를 대상으로 50mm 고정 초점 거리에서 카메라와 피사체 간 거리를 1.10m에서 2.20m까지, 높이는 유두 상하 30cm 범위에서 10cm 간격으로 변화시키며 정면 및 측면 사진을 촬영하였다. 두 명의 연구자가 버니어 캘리퍼스와 포토샵(Photoshop)을 사용하여 11개의 선형 파라미터, 3개의 면적 파라미터, 3개의 비율 파라미터를 독립적으로 평가하였다.
【주요 결과】
두 연구자 간 상관 계수는 0.922에서 0.999로 높은 일치도를 보였으나, 포토샵 측정치는 버니어 캘리퍼 측정치보다 평균 29.67% 더 크게 나타났다. 거리 그룹 간 비율 파라미터는 유의한 변화가 없었으나, 선형 및 면적 파라미터는 피사체 거리가 가까워질수록 유의하게 증가하였다. 또한 촬영 높이가 낮아질수록 유방 하부가 넓고 평평해지며 유방 전체에서 차지하는 비율이 증가하는 왜곡 현상이 관찰되었다.
【임상적 시사점 (성형외과 의사 관점)】
성형외과 의사들은 유방 성형술(breast augmentation)이나 유방 재건술(breast reconstruction) 후 환자 추적 관찰 시, 촬영 거리와 높이가 표준화되지 않으면 유방 형태 변화의 객관적 평가가 불가능함을 인지해야 한다. 특히 유방 하부 확장(lower pole expansion)이나 하중감하(hanging)의 정도를 평가할 때는 촬영 높이의 영향을 배제하기 어렵으므로, 일관된 비교를 위해 유두를 기준으로 한 고정된 촬영 높이를 유지해야 한다. 수술 전 상담이나 사후 결과 비교를 위한 사진 촬영 시 카메라와 피사체 간 거리를 1.5~1.7m로 고정하는 것이 왜곡을 최소화하고 균일한 이미지를 확보하는 데 필수적이다. 디지털 이미지 분석 도구를 사용할 경우, 물리적 측정 도구와 비교 시 약 30%의 과대 평가 경향이 있으므로, 정량적 데이터를 해석할 때 이 보정 계수를 고려해야 한다. 환자 상담 시 사진 각도에 따른 시각적 왜곡을 설명하고, 수술 결과의 객관적 증거로 사진을 제시할 때 촬영 조건이 통제되었음을 명시하는 것이 법적·의학적 분쟁 예방에 도움이 된다.
추출된 의학 개체 (NER)
전체 NER 표 보기
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 14 | |
| 해부 | lateral
|
scispacy | 1 | ||
| 해부 | nipple
|
scispacy | 1 | ||
| 약물 | Camera-to-Subject
|
scispacy | 1 | ||
| 질환 | breast deformation
|
C0567474
Deformity of breast
|
scispacy | 1 | |
| 질환 | height affects breast distortion
|
scispacy | 1 | ||
| 질환 | breast cup
|
scispacy | 1 | ||
| 질환 | nipple
|
scispacy | 1 | ||
| 질환 | Bullet
|
scispacy | 1 |
🏷️ 키워드 / MeSH 📖 같은 키워드 OA만
함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
같은 제1저자의 인용 많은 논문 (5)
- Machine learning for identifying risk factors of nosocomial infection in cancer patients with immune checkpoint inhibitor-related pneumonia.
- A structured, indicator-driven quality improvement cycle is associated with improved adherence and outcomes after liver resection for hepatocellular carcinoma.
- Advances in organelle-targeted photosensitizer-mediated pyroptosis for photodynamic tumor therapy: overcoming immunological limitations.
- Synthesis, radiolabeling, and evaluation of a Ga-labeled tyrosine kinase inhibitor for detecting EGFR mutations .
- Bibliometric analysis reveals the current status and future trends of cancer associated photodynamic therapy in breast cancer.
🏷️ 같은 키워드 · 무료전문 — 이 논문 MeSH/keyword 기반
- A Phase I Study of Hydroxychloroquine and Suba-Itraconazole in Men with Biochemical Relapse of Prostate Cancer (HITMAN-PC): Dose Escalation Results.
- Self-management of male urinary symptoms: qualitative findings from a primary care trial.
- Clinical and Liquid Biomarkers of 20-Year Prostate Cancer Risk in Men Aged 45 to 70 Years.
- Diagnostic accuracy of Ga-PSMA PET/CT versus multiparametric MRI for preoperative pelvic invasion in the patients with prostate cancer.
- Association of patient health education with the postoperative health related quality of life in low- intermediate recurrence risk differentiated thyroid cancer patients.
- Early local immune activation following intra-operative radiotherapy in human breast tissue.
📖 비슷한 OA 논문 — 같은 카테고리, 무료 전문 가능
- Current Concepts in Capsular Contracture: Pathophysiology, Prevention, and Management.
- The Relationship of Bacterial Biofilms and Capsular Contracture in Breast Implants.
- Factors Influencing Patient Satisfaction With Breast Augmentation: A BREAST-Q Effect of Magnitude Analysis.
-
The Keller Funnel, Capsular Contracture, and Conflict of Interest: A Review.
TL;DRNo reliable evidence supports the use of a Keller funnel to reduce the risk of capsular contracture, and both supportive studies contain confounding variables, limited follow-up ti…
- Keller Funnel Efficacy in "No Touch" Breast Augmentation and Reconstruction: A Systematic Review.