Comparative Performance of Artificial Intelligence-Based Computer-Aided Detection Systems for Colorectal Polyps: A Systematic Review and Network Meta-Analysis.
메타분석
2/5 보강
OpenAlex 토픽 ·
Colorectal Cancer Screening and Detection
AI in cancer detection
COVID-19 diagnosis using AI
[BACKGROUND AND AIMS] Computer-aided detection (CADe) is anticipated to enhance adenoma detection rate (ADRs).
- 연구 설계 meta-analysis
APA
Satoshi Shinozaki, J Watanabe, et al. (2026). Comparative Performance of Artificial Intelligence-Based Computer-Aided Detection Systems for Colorectal Polyps: A Systematic Review and Network Meta-Analysis.. Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society, 38(4), e70138. https://doi.org/10.1111/den.70138
MLA
Satoshi Shinozaki, et al.. "Comparative Performance of Artificial Intelligence-Based Computer-Aided Detection Systems for Colorectal Polyps: A Systematic Review and Network Meta-Analysis.." Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society, vol. 38, no. 4, 2026, pp. e70138.
PMID
41906553 ↗
Abstract 한글 요약
[BACKGROUND AND AIMS] Computer-aided detection (CADe) is anticipated to enhance adenoma detection rate (ADRs). The aim of this study was to systematically collect randomized-controlled trials comparing colonoscopy with CADe to standard colonoscopy without CADe in ADRs.
[METHODS] We performed a Bayesian network meta-analysis of randomized-controlled trials. Three electronic databases including MEDLINE, Embase, and the Cochrane Central Register of Controlled Trials were searched. The primary outcome was the comparison of the performance of CADe systems in ADRs; the secondary outcome was the sessile serrated lesions detection rates (SSLDRs).
[RESULTS] A total of 48 randomized controlled trials involving 38,986 patients were included in the quantitative analysis. Several CADe systems improved ADR compared with controls that ENDO-AID (risk ratio [RR] 1.26, 95% credible interval [CrI] 1.14-1.40), CADEYE (RR 1.18, 95% CrI 1.10-1.26), and GI Genius (RR 1.15, 95% CrI 1.08-1.22) were supported by moderate confidence evidence according to the Confidence in Network Meta-Analysis (CINeMA). For SSLDR, ENDO-AID (RR 1.36, 95% CrI 1.03-1.79) and GI Genius (RR 1.25, 95% CrI 1.08-1.46) may offer improved detection compared with controls. Across multiple sensitivity analyses excluding studies by withdrawal time, conflicts of interest, limited study numbers, image-enhanced endoscopy, non-parallel design, single-center settings, operator experience, or earlier publication years, the direction and magnitude of ADR improvements with CADe systems remained largely consistent with the primary analysis.
[CONCLUSIONS] Based on the CINeMA framework, the certainty of evidence ranged from low to moderate, indicating that some CADe systems are likely to improve ADR.
[METHODS] We performed a Bayesian network meta-analysis of randomized-controlled trials. Three electronic databases including MEDLINE, Embase, and the Cochrane Central Register of Controlled Trials were searched. The primary outcome was the comparison of the performance of CADe systems in ADRs; the secondary outcome was the sessile serrated lesions detection rates (SSLDRs).
[RESULTS] A total of 48 randomized controlled trials involving 38,986 patients were included in the quantitative analysis. Several CADe systems improved ADR compared with controls that ENDO-AID (risk ratio [RR] 1.26, 95% credible interval [CrI] 1.14-1.40), CADEYE (RR 1.18, 95% CrI 1.10-1.26), and GI Genius (RR 1.15, 95% CrI 1.08-1.22) were supported by moderate confidence evidence according to the Confidence in Network Meta-Analysis (CINeMA). For SSLDR, ENDO-AID (RR 1.36, 95% CrI 1.03-1.79) and GI Genius (RR 1.25, 95% CrI 1.08-1.46) may offer improved detection compared with controls. Across multiple sensitivity analyses excluding studies by withdrawal time, conflicts of interest, limited study numbers, image-enhanced endoscopy, non-parallel design, single-center settings, operator experience, or earlier publication years, the direction and magnitude of ADR improvements with CADe systems remained largely consistent with the primary analysis.
[CONCLUSIONS] Based on the CINeMA framework, the certainty of evidence ranged from low to moderate, indicating that some CADe systems are likely to improve ADR.
🏷️ 키워드 / MeSH 📖 같은 키워드 OA만
같은 제1저자의 인용 많은 논문 (1)
🏷️ 같은 키워드 · 무료전문 — 이 논문 MeSH/keyword 기반
- A Phase I Study of Hydroxychloroquine and Suba-Itraconazole in Men with Biochemical Relapse of Prostate Cancer (HITMAN-PC): Dose Escalation Results.
- Self-management of male urinary symptoms: qualitative findings from a primary care trial.
- Clinical and Liquid Biomarkers of 20-Year Prostate Cancer Risk in Men Aged 45 to 70 Years.
- Diagnostic accuracy of Ga-PSMA PET/CT versus multiparametric MRI for preoperative pelvic invasion in the patients with prostate cancer.
- Comprehensive analysis of androgen receptor splice variant target gene expression in prostate cancer.
- Clinical Presentation and Outcomes of Patients Undergoing Surgery for Thyroid Cancer.