Buckled upper pole breast style 410 implant presenting as a manifestation of capsular contraction.

Aesthetic plastic surgery 1999 Vol.23(4) p. 279-81

Hodgkinson DJ

관련 도메인

Abstract

Recent experience with the cohesive gel implant has shown an interesting variation of capsular contracture. Instead of spherical contraction, the capsule formation around the 410 implant seems to cause a buckling of the superior pole of the implant. This buckling has been observed in four implants and presented clinically in 2 of 50 patients with a superior pole mass. The capsular contraction around the implant and the buckling are probably camouflaged by a subpectoral implantation and this presentation should be recognized by the surgeon, especially when considering placement of the cohesive gel implant in a subglandular position. Histological sections of a capsule around the implant show fragmented silicone, with a cellular reaction around the fragmented silicone.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
해부 capsular scispacy 1
해부 subglandular scispacy 1
해부 cellular scispacy 1
해부 breast 유방 dict 1
합병증 capsular contracture 피막구축 dict 1
약물 silicone C0037114
silicones
scispacy 1
기법 subpectoral 근막하 평면 dict 1
질환 capsule scispacy 1
기타 patients scispacy 1

MeSH Terms

Breast Implants; Female; Gels; Humans; Prosthesis Failure