One-Stage Implant-Based Breast Reconstruction With Polyurethane-Coated Device: Standardized Assessment of Outcomes.

Aesthetic surgery journal 2024 Vol.44(5) p. 491-498

Catanuto G, Virzì D, Latino M, Musmeci N, Fichera D, Balafa K, Cannata I, Rocco N, Marino M, Castiglione G, Caruso F

관련 도메인

Abstract

[BACKGROUND] Nipple-sparing mastectomies (NSMs) and implant-based breast reconstructions have evolved from 2-stage reconstructions with tissue expansion and implant exchange to direct-to-implant procedures. In this study, we tested safety and efficacy of polyurethane-based implants according to standard assessment tools.

[OBJECTIVES] This study aimed to test safety and feasibility of polyurethane-coated implants with standardized assessment employing internationally acknowledged evaluation criteria.

[METHODS] Cases of NSMs followed by breast reconstruction in 1 stage with immediate prepectoral polyurethane-coated implant placement were retrospectively reviewed. Preoperative characteristics of the population have been collected. Adherence to quality assurance criteria of the Association of Breast Surgery-British Association of Plastic Reconstructive and Aesthetic Surgeons was verified. Complications were assessed with the Clavien Dindo classification, modified for the breast. Rippling, implant rotation, and malposition were also evaluated.

[RESULTS] Sixty-three consecutive patients underwent 74 NSMs and immediate breast reconstruction with micro polyurethane foam-coated anatomic implants. In 5 cases we had unplanned readmissions with return to the operating room under general anesthesia (6.7%) and implant loss within 3 months from breast reconstruction (5 implants, 6.7%). Postoperative complications according to Clavien Dindo were grade 1 in 6 cases (8.1%), grade 2 in 3 cases (4%), and 3b in 5 cases (6.7%).

[CONCLUSIONS] Polyurethane-coated implants may prevent rotation and malposition and capsular contracture in the short term. Unplanned readmission rates and implant loss rates in the short term may be slightly higher.See the abstract translated into Hindi, Portuguese, Korean, German, Italian, Arabic, Chinese, and Taiwanese online here: https://doi.org/10.1093/asj/sjad301.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
해부 breast 유방 dict 7
해부 tissue scispacy 1
합병증 prepectoral polyurethane-coated scispacy 1
합병증 capsular contracture 피막구축 dict 1
약물 polyurethane-based scispacy 1
약물 micro polyurethane scispacy 1
약물 [BACKGROUND] Nipple-sparing mastectomies scispacy 1
약물 [OBJECTIVES] scispacy 1
약물 [CONCLUSIONS] Polyurethane-coated implants may scispacy 1
질환 Rippling, implant rotation scispacy 1
질환 implant loss scispacy 1
질환 NSMs → Nipple-sparing mastectomies scispacy 1
질환 Breast Surgery-British scispacy 1
기타 patients scispacy 1

MeSH Terms

Humans; Female; Breast Implants; Breast Implantation; Retrospective Studies; Polyurethanes; Mammaplasty; Breast Neoplasms

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문