Influence of stereopsis on the ability to perform simulated microsurgery.
Abstract
[PURPOSE] To determine whether impaired or absent stereopsis affects the ability to perform simulated microsurgical tasks.
[SETTING] University of Edinburgh, United Kingdom.
[DESIGN] Prospective randomized cross-over study.
[METHODS] Visual acuity and stereoacuity were measured. A band-pass filter was placed over the nondominant eye to reduce stereoacuity to 150 seconds of an arc (partial stereopsis), or the nondominant eye was completely occluded (absent stereopsis). Participants completed a computerized surgical simulator task 3 times with a randomized testing order (normal stereopsis, absent stereopsis, and partial stereopsis). The task involved using forceps to grasp and position objects in the anterior chamber. Outcomes included area of ocular injury, time to task completion, and overall score.
[RESULTS] Ocular damage area was significantly worse with partial stereopsis (P = .002) and worse still when stereopsis was absent (P < .001 for normal vs absent stereopsis and P = .005 for partial vs absent stereopsis). The median ocular damage area was 3.55 mm (interquartile range [IQR], 1.21-5.88 mm) with normal stereopsis, increasing to 6.10 mm (IQR, 3.96-12.47 mm) with stereopsis reduced to 150 seconds of an arc and to 9.25 mm (IQR, 4.93-18.70 mm) with no stereopsis. Time taken to complete the task increased and overall score decreased as stereopsis was reduced. The overall score decreased from 53% (IQR, 22.5-82%) under normal stereopsis to 0% (IQR, 0-43.5%) with absent stereopsis.
[CONCLUSIONS] Impaired stereopsis was associated with worse microsurgical performance, which may have implications for surgical training. The absence of stereopsis resulted in worse performance than partial reduction in stereopsis.
[SETTING] University of Edinburgh, United Kingdom.
[DESIGN] Prospective randomized cross-over study.
[METHODS] Visual acuity and stereoacuity were measured. A band-pass filter was placed over the nondominant eye to reduce stereoacuity to 150 seconds of an arc (partial stereopsis), or the nondominant eye was completely occluded (absent stereopsis). Participants completed a computerized surgical simulator task 3 times with a randomized testing order (normal stereopsis, absent stereopsis, and partial stereopsis). The task involved using forceps to grasp and position objects in the anterior chamber. Outcomes included area of ocular injury, time to task completion, and overall score.
[RESULTS] Ocular damage area was significantly worse with partial stereopsis (P = .002) and worse still when stereopsis was absent (P < .001 for normal vs absent stereopsis and P = .005 for partial vs absent stereopsis). The median ocular damage area was 3.55 mm (interquartile range [IQR], 1.21-5.88 mm) with normal stereopsis, increasing to 6.10 mm (IQR, 3.96-12.47 mm) with stereopsis reduced to 150 seconds of an arc and to 9.25 mm (IQR, 4.93-18.70 mm) with no stereopsis. Time taken to complete the task increased and overall score decreased as stereopsis was reduced. The overall score decreased from 53% (IQR, 22.5-82%) under normal stereopsis to 0% (IQR, 0-43.5%) with absent stereopsis.
[CONCLUSIONS] Impaired stereopsis was associated with worse microsurgical performance, which may have implications for surgical training. The absence of stereopsis resulted in worse performance than partial reduction in stereopsis.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | microsurgery
|
미세수술 | dict | 1 | |
| 해부 | eye
|
scispacy | 1 | ||
| 해부 | anterior
|
scispacy | 1 | ||
| 약물 | [DESIGN]
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS]
|
scispacy | 1 | ||
| 질환 | ocular injury
|
C0015408
Eye Injuries
|
scispacy | 1 | |
| 질환 | Ocular damage
|
scispacy | 1 |
MeSH Terms
Cataract Extraction; Computer Simulation; Cross-Over Studies; Depth Perception; Female; Humans; Male; Microsurgery; Perceptual Disorders; Prospective Studies; Task Performance and Analysis; Vision, Binocular; Visual Acuity; Young Adult
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Endodontic implications of hypercementosis: A systematic review of anatomical challenges and therapeutic strategies.
- Breast plastic surgery in perimenopausal and postmenopausal women: Menopause-informed counseling on screening, safety, and long-term breast health.
- Application of the SCIA-Pure Skin Perforator Flap in Bilateral Upper Eyelid Reconstruction: A Case Report and Review of the Literature.
- Free flap reconstruction of a cast-related pressure ulcer in a pediatric patient with spinal muscular atrophy.
- Characterization of Trimmed Nerve Morphology Using High-Resolution Imaging: Comparison of Three Surgical Instruments.