[Use of coupler for venous anastomoses in cervico-facial reconstruction. Retrospective study on 51 free flaps].
[OBJECTIVE] The aim of our study was to evaluate the interest of the mechanical anastomosic coupling device for venous anastomoses in a series of cervico-facial reconstructions after carcinologic exci
- 표본수 (n) 18
APA
Vernier-Mosca M, Feuvrier D, et al. (2020). [Use of coupler for venous anastomoses in cervico-facial reconstruction. Retrospective study on 51 free flaps].. Annales de chirurgie plastique et esthetique, 65(3), 236-243. https://doi.org/10.1016/j.anplas.2019.06.011
MLA
Vernier-Mosca M, et al.. "[Use of coupler for venous anastomoses in cervico-facial reconstruction. Retrospective study on 51 free flaps].." Annales de chirurgie plastique et esthetique, vol. 65, no. 3, 2020, pp. 236-243.
PMID
31353075
Abstract
[OBJECTIVE] The aim of our study was to evaluate the interest of the mechanical anastomosic coupling device for venous anastomoses in a series of cervico-facial reconstructions after carcinologic excision.
[PATIENTS AND METHODS] Between January 2010 and December 2017, 46 patients underwent free flap cervico-facial reconstruction. We performed 54 venous anastomoses for 51 free flaps. Mechanical venous anastomoses were performed with a coupler (Coupler®). Thrombotic complications and choice of recipient vessels were assessed for the entire series.
[RESULTS] Venous anastomoses were performed using a coupler in 33.3% of the flaps (n=18). Mean operative time was lower for reconstructions with mechanical coupler anastomoses, and significantly for fibula flaps. Of eight thromboses, six were venous, two of which after the coupler anastomosis. The thrombosed veins were the branches of the internal jugular vein and the anterior jugular veins. The diameter of the couplers used was respectively 2.5mm and 2mm.
[CONCLUSION] The use of the microvascular coupling system for venous anastomoeis would help reduce the occurrence of venous thrombosis, but larger and prospective studies should be conducted. This coupling system, relatively easy to use, would overcome the lack of congruence of anastomosing veins and reduce the risk of intimal injury. Regarding the recipient vessels, the anterior jugular vein should not be used as first line because the risk of vascular complications seems more important.
[PATIENTS AND METHODS] Between January 2010 and December 2017, 46 patients underwent free flap cervico-facial reconstruction. We performed 54 venous anastomoses for 51 free flaps. Mechanical venous anastomoses were performed with a coupler (Coupler®). Thrombotic complications and choice of recipient vessels were assessed for the entire series.
[RESULTS] Venous anastomoses were performed using a coupler in 33.3% of the flaps (n=18). Mean operative time was lower for reconstructions with mechanical coupler anastomoses, and significantly for fibula flaps. Of eight thromboses, six were venous, two of which after the coupler anastomosis. The thrombosed veins were the branches of the internal jugular vein and the anterior jugular veins. The diameter of the couplers used was respectively 2.5mm and 2mm.
[CONCLUSION] The use of the microvascular coupling system for venous anastomoeis would help reduce the occurrence of venous thrombosis, but larger and prospective studies should be conducted. This coupling system, relatively easy to use, would overcome the lack of congruence of anastomosing veins and reduce the risk of intimal injury. Regarding the recipient vessels, the anterior jugular vein should not be used as first line because the risk of vascular complications seems more important.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | free flap
|
피판재건술 | dict | 1 | |
| 시술 | microvascular
|
미세수술 | dict | 1 | |
| 해부 | Thrombotic
|
scispacy | 1 | ||
| 해부 | intimal
|
scispacy | 1 | ||
| 합병증 | flaps
|
scispacy | 1 | ||
| 합병증 | anastomosic
|
scispacy | 1 | ||
| 합병증 | flap cervico-facial
|
scispacy | 1 | ||
| 질환 | anastomosic
|
scispacy | 1 | ||
| 질환 | Thrombotic complications
|
scispacy | 1 | ||
| 질환 | venous thrombosis
|
C0042487
Venous Thrombosis
|
scispacy | 1 | |
| 질환 | intimal injury
|
scispacy | 1 | ||
| 질환 | cervico-facial
|
scispacy | 1 | ||
| 기타 | venous
|
scispacy | 1 | ||
| 기타 | venous anastomoses
|
scispacy | 1 | ||
| 기타 | vessels
|
scispacy | 1 | ||
| 기타 | flaps
|
scispacy | 1 | ||
| 기타 | fibula flaps
|
scispacy | 1 | ||
| 기타 | veins
|
scispacy | 1 | ||
| 기타 | jugular vein
|
scispacy | 1 | ||
| 기타 | anterior jugular veins
|
scispacy | 1 | ||
| 기타 | anterior jugular vein
|
scispacy | 1 | ||
| 기타 | vascular
|
scispacy | 1 |
MeSH Terms
Aged; Anastomosis, Surgical; Female; Free Tissue Flaps; Head and Neck Neoplasms; Humans; Male; Middle Aged; Plastic Surgery Procedures; Retrospective Studies; Vascular Surgical Procedures; Veins
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
같은 제1저자의 인용 많은 논문 (1)
관련 논문
- Endodontic implications of hypercementosis: A systematic review of anatomical challenges and therapeutic strategies.
- Breast plastic surgery in perimenopausal and postmenopausal women: Menopause-informed counseling on screening, safety, and long-term breast health.
- Application of the SCIA-Pure Skin Perforator Flap in Bilateral Upper Eyelid Reconstruction: A Case Report and Review of the Literature.
- Free flap reconstruction of a cast-related pressure ulcer in a pediatric patient with spinal muscular atrophy.
- Characterization of Trimmed Nerve Morphology Using High-Resolution Imaging: Comparison of Three Surgical Instruments.