Biomechanical comparison of polylactide-based versus titanium miniplates in mandible reconstruction in vitro.
Abstract
[OBJECTIVES] Evaluation of the mechanical integrity and reliability of polylactide-based miniplates for osseous free flap fixation at the mandible in an experimental study setup of a mandible reconstruction model.
[MATERIAL AND METHODS] 1.0mm titanium miniplates (group TI) (MatrixMandible, DePuy Synthes, Umkirch, Germany) and 1.5mm polylactide miniplates (group PL) (Inion CPS, Inion Oy, Tampere, Finland) were used to fix a polyurethane (PU) fibula segment to a PU mandible reconstruction model using monocortical non-locking screws. Mastication was simulated via unilateral cyclic dynamic loading at 1Hz with increasing loads (+ 0.15N/cycle, Bionix, MTS, USA). A 3D optical tracking system (Aramis, GOM, Braunschweig, Germany) was used to determine interosteotomy movements (IOM).
[RESULTS] IOM were higher in the polylactide group (distal: P=0.001, mesial: P=0.001). Differences in mean stiffness (titanium: 478±68N/mm; polylactide: 425±38N/mm, P=0.240) and mean force at a vertical displacement of 1.0mm (titanium: 201.6±87.1N; polylactide: 141.3±29.9N, P=0.159) were not significant.
[CONCLUSIONS] The results of this study suggest that polylactide-based miniplates provide reduced mechanical integrity and higher interosteotomy movements in comparison to titanium miniplates in vitro. Indications for clinical use of polylactide-based miniplates in mandible reconstruction have to be placed critically. Future studies will focus on clinical complications of polylactide-based plates in risk patients.
[MATERIAL AND METHODS] 1.0mm titanium miniplates (group TI) (MatrixMandible, DePuy Synthes, Umkirch, Germany) and 1.5mm polylactide miniplates (group PL) (Inion CPS, Inion Oy, Tampere, Finland) were used to fix a polyurethane (PU) fibula segment to a PU mandible reconstruction model using monocortical non-locking screws. Mastication was simulated via unilateral cyclic dynamic loading at 1Hz with increasing loads (+ 0.15N/cycle, Bionix, MTS, USA). A 3D optical tracking system (Aramis, GOM, Braunschweig, Germany) was used to determine interosteotomy movements (IOM).
[RESULTS] IOM were higher in the polylactide group (distal: P=0.001, mesial: P=0.001). Differences in mean stiffness (titanium: 478±68N/mm; polylactide: 425±38N/mm, P=0.240) and mean force at a vertical displacement of 1.0mm (titanium: 201.6±87.1N; polylactide: 141.3±29.9N, P=0.159) were not significant.
[CONCLUSIONS] The results of this study suggest that polylactide-based miniplates provide reduced mechanical integrity and higher interosteotomy movements in comparison to titanium miniplates in vitro. Indications for clinical use of polylactide-based miniplates in mandible reconstruction have to be placed critically. Future studies will focus on clinical complications of polylactide-based plates in risk patients.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | mandible
|
하악골 | dict | 5 | |
| 시술 | free flap
|
피판재건술 | dict | 1 | |
| 해부 | flap
|
scispacy | 1 | ||
| 해부 | polylactide-based miniplates
|
scispacy | 1 | ||
| 약물 | titanium
|
C0040302
titanium
|
scispacy | 1 | |
| 약물 | PU mandible
|
C0024687
Mandible
|
scispacy | 1 | |
| 약물 | [OBJECTIVES]
|
scispacy | 1 | ||
| 약물 | [MATERIAL AND METHODS] 1.0mm titanium miniplates
|
scispacy | 1 | ||
| 약물 | [RESULTS] IOM
|
scispacy | 1 | ||
| 약물 | polylactide
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS]
|
scispacy | 1 | ||
| 기타 | CPS
|
scispacy | 1 | ||
| 기타 | PU mandible
|
scispacy | 1 | ||
| 기타 | 478±68N/mm
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 |
MeSH Terms
Bone Plates; Humans; Mandible; Polyesters; Reproducibility of Results; Titanium
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Endodontic implications of hypercementosis: A systematic review of anatomical challenges and therapeutic strategies.
- Breast plastic surgery in perimenopausal and postmenopausal women: Menopause-informed counseling on screening, safety, and long-term breast health.
- Application of the SCIA-Pure Skin Perforator Flap in Bilateral Upper Eyelid Reconstruction: A Case Report and Review of the Literature.
- Free flap reconstruction of a cast-related pressure ulcer in a pediatric patient with spinal muscular atrophy.
- Characterization of Trimmed Nerve Morphology Using High-Resolution Imaging: Comparison of Three Surgical Instruments.