[BACKGROUND] Titanium plate fixation of free flaps in mandibular reconstruction involves complications such as osseous non-union or imaging artefacts. Interosteotomy movement (IOM) is known to affect bone healing. This study aimed to compare IOM and mechanical integrity of four different fixation systems in a mandible reconstruction model.

[METHODS] Two polyurethane (PU) fibula segments were fixed in right-sided defects of PU mandibles. Laser-melted patient-specific titanium plates were fixed with non-locking-screws (Ti-NL) or locking-screws (Ti-L). The third group consisted of locking-screws for patient-specific polyetheretherketone (PEEK-L) plates. The last group used titanium miniplates and monocortical screw fixation (Ti-MP). All models were loaded unilaterally via cyclic dynamic loading with increasing loads to simulate mastication. IOM was registered using a 3D optical tracking system.

[FINDINGS] PEEK-L showed highest vertical displacement (p = 0.010), lowest stiffness (p = 0.004) and highest IOM (p = 0.001). All specimen in PEEK-L demonstrated abnormal bending (n = 5) or plate fracture (n = 1). Vertical displacement or stiffness did not differ between any of Ti-MP, Ti-L and Ti-NL. IOM in Ti-MP was higher than in Ti-L and Ti-NL (p = 0.001).

[INTERPRETATION] Mechanical integrity of all titanium plates complies with established standards. In this model, the screw system did not influence IOM. In the tested composition and shape, PEEK plates do not seem to guarantee sufficient mechanical integrity for a use in mandibular reconstruction. Thus modifications are needed. Future clinical studies are needed to clarify optimal IOM after mandible reconstruction.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
해부 mandible 하악골 dict 2
해부 mandibular scispacy 1
해부 flaps scispacy 1
해부 bone scispacy 1
합병증 osseous scispacy 1
약물 Ti-MP → titanium miniplates and monocortical screw fixation scispacy 1
약물 PEEK C0084113
polyetheretherketone
scispacy 1
약물 [BACKGROUND] Titanium scispacy 1
약물 titanium C0040302
titanium
scispacy 1
약물 polyetheretherketone C0084113
polyetheretherketone
scispacy 1
질환 Ti-MP → titanium miniplates and monocortical screw fixation scispacy 1
질환 abnormal bending scispacy 1
질환 fracture C0016658
Fracture
scispacy 1
질환 osseous non-union scispacy 1
기타 mandibular scispacy 1
기타 PU mandibles scispacy 1
기타 Ti-MP → titanium miniplates and monocortical screw fixation scispacy 1

MeSH Terms

Biomechanical Phenomena; Bone Plates; Fracture Fixation, Internal; Humans; Mandibular Reconstruction; Titanium

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문