본문으로 건너뛰기
← 뒤로

Experimental Study of Microvascular Anastomosis: Comparison of the Conventional Method, Back Wall Technique, and Untied Stay Suture Method.

기술보고 1/5 보강
The journal of hand surgery Asian-Pacific volume 2021 Vol.26(3) p. 364-370
Retraction 확인
출처

Arai S

관련 도메인

📝 환자 설명용 한 줄

Compared with the conventional microvascular anastomosis method, the back wall technique and untied stay suture method allow for better visualization of the vascular lumen and have been reported to be

이 논문을 인용하기

↓ .bib ↓ .ris
APA Arai S (2021). Experimental Study of Microvascular Anastomosis: Comparison of the Conventional Method, Back Wall Technique, and Untied Stay Suture Method.. The journal of hand surgery Asian-Pacific volume, 26(3), 364-370. https://doi.org/10.1142/S2424835521500338
MLA Arai S. "Experimental Study of Microvascular Anastomosis: Comparison of the Conventional Method, Back Wall Technique, and Untied Stay Suture Method.." The journal of hand surgery Asian-Pacific volume, vol. 26, no. 3, 2021, pp. 364-370.
PMID 34380402 ↗

Abstract

Compared with the conventional microvascular anastomosis method, the back wall technique and untied stay suture method allow for better visualization of the vascular lumen and have been reported to be effective for beginner surgeons. However, there are no reports of such advantages from experimental studies. The present study compared the usefulness of the conventional method (Method C), back wall technique (Method B), and untied stay suture method (Method U) in rats. Ninety end-to-end anastomosis procedures of the right femoral artery and vein were performed in rats. The anastomosis condition was assessed at the completion of suturing one side, at the completion of vascular anastomosis, and on postoperative day 7. After suturing one side, suture errors were observed in three veins with Method C. Immediately after the completion of vascular anastomosis, blood flow was impaired in one vein with Method C. On postoperative day 7, blood flow was impaired in one artery and one vein with Method C, one vein with Method B, and one artery with Method U. No significant differences were observed between back wall technique and the untied stay suture method. However, the conventional method was more likely to lead to suture error or impaired blood flow compared with back wall technique and the untied stay suture method.

추출된 의학 개체 (NER)

전체 NER 표 보기
유형영어 표현한국어 / 풀이UMLS CUI출처등장
시술 microvascular 미세수술 dict 2
해부 back wall scispacy 1
해부 vascular lumen scispacy 1
해부 blood scispacy 1
해부 vein scispacy 1
기타 Wall scispacy 1
기타 rats scispacy 1
기타 femoral artery scispacy 1
기타 vein scispacy 1
기타 vascular scispacy 1
기타 veins scispacy 1
기타 artery scispacy 1
기타 back wall scispacy 1

🏷️ 키워드 / MeSH 📖 같은 키워드 OA만

함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

같은 제1저자의 인용 많은 논문 (3)

🏷️ 같은 키워드 · 무료전문 — 이 논문 MeSH/keyword 기반

📖 비슷한 OA 논문 — 같은 카테고리, 무료 전문 가능