Assessment and Comparison of Three Dimensional Exoscopes for Near-Infrared Fluorescence-Guided Surgery Using Second-Window Indocyanine-Green.

Journal of Korean Neurosurgical Society 2022 Vol.65(4) p. 572-581

Cho SS, Teng CW, De Ravin E, Singh YB, Lee JYK

관련 도메인

Abstract

[OBJECTIVE] Compared to microscopes, exoscopes have advantages in field-depth, ergonomics, and educational value. Exoscopes are especially well-poised for adaptation into fluorescence-guided surgery (FGS) due to their excitation source, light path, and image processing capabilities. We evaluated the feasibility of near-infrared FGS using a 3-dimensional (3D), 4 K exoscope with nearinfrared fluorescence imaging capability. We then compared it to the most sensitive, commercially-available near-infrared exoscope system (3D and 960 p). In-vitro and intraoperative comparisons were performed.

[METHODS] Serial dilutions of indocyanine-green (1-2000 μg/mL) were imaged with the 3D, 4 K Olympus Orbeye (system 1) and the 3D, 960 p VisionSense Iridium (system 2). Near-infrared sensitivity was calculated using signal-to-background ratios (SBRs). In addition, three patients with brain tumors were administered indocyanine-green and imaged with system 1, with two also imaged with system 2 for comparison.

[RESULTS] Systems 1 and 2 detected near-infrared fluorescence from indocyanine green concentrations of >250 μg/L and >31.3 μg/L, respectively. Intraoperatively, system 1 visualized strong near-infrared fluorescence from two, strongly gadoliniumenhancing meningiomas (SBR=2.4, 1.7). The high-resolution, bright images were sufficient for the surgeon to appreciate the underlying anatomy in the near-infrared mode. However, system 1 was not able to visualize fluorescence from a weakly-enhancing intraparenchymal metastasis. In contrast, system 2 successfully visualized both the meningioma and the metastasis but lacked high resolution stereopsis.

[CONCLUSION] Three-dimensional exoscope systems provide an alternative visualization platform for both standard microsurgery and near-infrared fluorescent guided surgery. However, when tumor fluorescence is weak (i.e., low fluorophore uptake, deep tumors), highly sensitive near-infrared visualization systems may be required.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
시술 microsurgery 미세수술 dict 1
합병증 intraparenchymal scispacy 1
약물 indocyanine-green scispacy 1
약물 indocyanine green C0021234
indocyanine green
scispacy 1
약물 [OBJECTIVE] scispacy 1
약물 [RESULTS] Systems 1 and 2 scispacy 1
질환 FGS → fluorescence-guided surgery C1880811
Fluorescence-Guided Surgery
scispacy 1
질환 tumors C0027651
Neoplasms
scispacy 1
질환 meningiomas C0025286
Meningioma
scispacy 1
질환 meningioma C0025286
Meningioma
scispacy 1
질환 tumor C0027651
Neoplasms
scispacy 1
질환 brain tumors scispacy 1
기타 field-depth scispacy 1
기타 patients scispacy 1
기타 SBR=2.4, 1.7) scispacy 1

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문