Virtual planning and 3D-printed guides for mandibular reconstruction: Factors impacting accuracy.

Laryngoscope investigative otolaryngology 2022 Vol.7(6) p. 1798-1807

Annino DJ, Sethi RK, Hansen EE, Horne S, Dey T, Rettig EM, Uppaluri R, Kass JI, Goguen LA

관련 도메인

Abstract

[OBJECTIVES] Examine accuracy and factors impacting accuracy for mandibular reconstruction with virtual surgical planning, 3D printed osteotomy guides and preoperatively bent mandibular reconstruction plate (VSP/3Dprinted-guide/plate).

[METHOD] Retrospective review of osseous-free-flap mandibular reconstructions with VSP/3Dprinted-guide/plate between January 2015 and July 2020 at a single academic medical center.Patient demographics, disease, and treatment variables were extracted. Accuracy was assessed by 3D-model-overlay with cephalometric and donor-bone segment length measurements. Multivariate analyses were performed to determine factors impacting cephalometric accuracy.

[RESULTS] 60 cases met criteria: 41 (68%) cancer, 14 (23%) osteoradionecrosis (ORN), 5 (8%) secondary mandibular reconstruction. Thirteen cases (22%) were Brown class III or IV. Thirty-nine cases (65%) had ≥2 flap bone segments. Average donor-bone length was 82 mm (SD: 28). 3D-model-overlay accuracy demonstrated minimal deviation between planned and actual reconstruction: intercondylar distance = 2.10 mm (SD: 2.2); intergonial distance = 2.23 mm (SD: 1.9); anterior-posterior distance (APD) = 1.76 mm (SD: 1.5); gonial angle (GA) = 3.11 degrees (SD: 2.4). Mean change in donor-bone segment length inferiorly was 2.67 mm (SD: 2.6) and superiorly 3.27 mm (SD: 3.2). Higher number of donor-bone segments was associated with decreased accuracy in GA ( = .023) and longer donor-bone length was associated with decreased accuracy in APD ( = .031).

[CONCLUSION] To our knowledge this is the largest series assessing surgical accuracy of VSP/3Dprinted-guide/plate for osseous-free-flap mandibular reconstruction. We demonstrate highly accurate results, with increased number of donor-bone segments and donor-bone length associated with decreased accuracy. Our findings further support VSP/3Dprinted-guide/plate as a reliable and accurate tool for mandibular reconstruction.

[LEVEL OF EVIDENCE] Level 4.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
시술 flap 피판재건술 dict 3
해부 mandibular scispacy 1
해부 intergonial scispacy 1
약물 donor-bone scispacy 1
약물 [OBJECTIVES] scispacy 1
약물 [RESULTS] 60 scispacy 1
질환 cancer C0006826
Malignant Neoplasms
scispacy 1
질환 osteoradionecrosis C0029461
Osteoradionecrosis
scispacy 1
질환 ORN → osteoradionecrosis scispacy 1
기타 mandibular scispacy 1
기타 Patient scispacy 1
기타 flap bone scispacy 1
기타 intercondylar scispacy 1
기타 anterior-posterior scispacy 1

📑 인용 관계

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문