본문으로 건너뛰기
← 뒤로

The Precision of Different Types of Plates Fabricated With a Computer-Aided Design and Manufacturing System in Mandibular Reconstruction With Fibular-Free Flaps.

The Journal of craniofacial surgery 2023 Vol.34(1) p. 187-197

Yodrabum N, Rudeejaroonrung K, Viriya N, Chaikangwan I, Kongkunnavat N, Tianrungroj J, Ongsiriporn M, Piyaman P, Puncreobutr C

관련 도메인

📝 환자 설명용 한 줄

Computer-assisted surgery (CAS) has been introduced to mandible reconstruction with fibular-free flap in cutting guide placement.

이 논문을 인용하기

BibTeX ↓ RIS ↓
APA Yodrabum N, Rudeejaroonrung K, et al. (2023). The Precision of Different Types of Plates Fabricated With a Computer-Aided Design and Manufacturing System in Mandibular Reconstruction With Fibular-Free Flaps.. The Journal of craniofacial surgery, 34(1), 187-197. https://doi.org/10.1097/SCS.0000000000009037
MLA Yodrabum N, et al.. "The Precision of Different Types of Plates Fabricated With a Computer-Aided Design and Manufacturing System in Mandibular Reconstruction With Fibular-Free Flaps.." The Journal of craniofacial surgery, vol. 34, no. 1, 2023, pp. 187-197.
PMID 36168132

Abstract

Computer-assisted surgery (CAS) has been introduced to mandible reconstruction with fibular-free flap in cutting guide placement. When CAS cooperates with different plate fixations, the results show various degrees of errors by which this study aimed to evaluate. Mock surgeries were conducted in 3D-printed mandibles with 2 types of defects, limited or extensive, reconstructed from 2 ameloblastoma patients. Three types of fixations, miniplate, manually bending reconstruction plate, and patient-specific plate, are tested, each of which was performed 3 times in each type of defect, adding up to 18 surgeries. One with the least errors was selected and applied to patients whose 3D-printed mandibles were derived. Finally, in vivo errors were compared with the mock. In limited defect, average errors show no statistical significance among all types. In extensive defect, patient-specific plate had a significantly lower average condylar error than manually bending reconstruction plate and miniplate (8.09±2.52 mm vs. 25.49±2.72 and 23.13±13.54 mm, respectively). When patient-specific plate was applied in vivo , the errors were not significantly different from the mock. Patient-specific plates that cooperated with CAS showed the least errors. Nevertheless, manually bent reconstruction plates and miniplates could be applied in limited defects with caution.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
시술 free flap 피판재건술 dict 1
해부 mandibles scispacy 1
해부 condylar scispacy 1
해부 miniplates scispacy 1
해부 mandible 하악골 dict 1
합병증 flap scispacy 1
약물 CAS → Computer-assisted surgery scispacy 1
질환 ameloblastoma C0002448
Ameloblastoma
scispacy 1
질환 ameloblastoma patients scispacy 1
기타 Mandibular scispacy 1

MeSH Terms

Humans; Free Tissue Flaps; Mandibular Reconstruction; Mandible; Computer-Aided Design; Ameloblastoma; Fibula; Bone Plates

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

같은 제1저자의 인용 많은 논문 (3)

관련 논문