How does the Number of Implants Affect Stress Distribution in Fibula Graft at the Posterior of the Mandible? A Finite Element Analysis.

Journal of maxillofacial and oral surgery 2023 Vol.22(2) p. 304-312 🌐 cited 3 🔓 OA Dental Implant Techniques and Outcom
📈 연도별 인용 (2024–2025) · 합계 3
OpenAlex 토픽 · Dental Implant Techniques and Outcomes Reconstructive Surgery and Microvascular Techniques Orthopaedic implants and arthroplasty

Latifi F, Tabrizi R, Hosseinikordkheili M

관련 도메인

📝 환자 설명용 한 줄

[OBJECTIVES] Evidence about the implant protocol and success in the osseous microvascular grafts is not sufficient.

이 논문을 인용하기

BibTeX ↓ RIS ↓
APA Fatemeh Latifi, Reza Tabrizi, Mohammadreza Hosseinikordkheili (2023). How does the Number of Implants Affect Stress Distribution in Fibula Graft at the Posterior of the Mandible? A Finite Element Analysis.. Journal of maxillofacial and oral surgery, 22(2), 304-312. https://doi.org/10.1007/s12663-022-01743-0
MLA Fatemeh Latifi, et al.. "How does the Number of Implants Affect Stress Distribution in Fibula Graft at the Posterior of the Mandible? A Finite Element Analysis.." Journal of maxillofacial and oral surgery, vol. 22, no. 2, 2023, pp. 304-312.
PMID 37122787

Abstract

[OBJECTIVES] Evidence about the implant protocol and success in the osseous microvascular grafts is not sufficient. Stress distribution around dental implants is one of the important factors determining treatment success. The purpose of this study was to evaluate stress distribution in the bone supporting the implants inserted in the fibula free flap, in patients with large defects in the posterior of the mandible by finite element analysis (FEA).

[MATERIALS AND METHODS] The CBCT was obtained from one patient with fibula free flap in the posterior of the mandible and also from a 4.1 × 10 mm implant (Zimmer, Zimmer dental, Carlsbad, USA). Two 3D finite models were designed containing three or four implants. The implants were splinted by a suprastructure. Vertical load (300 N) and oblique load (50 N) were applied to the suprastructure. The von Mises stress distribution and the micromotion of implants were evaluated.

[RESULTS] No significant difference was observed between implants micromotion in two models. According to stress distribution analysis and determining maximum stress regions, the model with four implants imposes more stress on titanium components and surrounding bone.

[CONCLUSION] The stress distribution around the implants of mandibular models with posterior defect that was reconstructed with fibula free flap is better in models with three fixtures versus four fixtures.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
시술 free flap 피판재건술 dict 3
해부 mandible 하악골 dict 3
시술 microvascular 미세수술 dict 1
해부 Fibula Graft scispacy 1
해부 bone scispacy 1
해부 fibula scispacy 1
해부 posterior scispacy 1
해부 mandibular scispacy 1
합병증 flap scispacy 1
약물 titanium C0040302
titanium
scispacy 1
기타 Carlsbad scispacy 1

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문