Use of the 4K-3D ORBEYE Exoscope for Supermicrosurgical Lymphaticovenular Anastomosis: A Case Report.

Cureus 2024 Vol.16(10) p. e71198 🌐 cited 1 🔓 OA Surgical Simulation and Training
TL;DR The 4K-3D ORBEYE system provided a good intraoperative outcome with greater ergonomics and a non-inferiority magnification compared to traditional microscopes, and represents a valid possibility to assist microsurgeons in lymphatic surgery.
OpenAlex 토픽 · Surgical Simulation and Training Minimally Invasive Surgical Techniques Colorectal Cancer Surgical Treatments

Caretto AA, Gentileschi S

관련 도메인

📝 환자 설명용 한 줄

The 4K-3D ORBEYE system provided a good intraoperative outcome with greater ergonomics and a non-inferiority magnification compared to traditional microscopes, and represents a valid possibility to as

이 논문을 인용하기

BibTeX ↓ RIS ↓
APA Anna Amelia Caretto, Stefano Gentileschi (2024). Use of the 4K-3D ORBEYE Exoscope for Supermicrosurgical Lymphaticovenular Anastomosis: A Case Report.. Cureus, 16(10), e71198. https://doi.org/10.7759/cureus.71198
MLA Anna Amelia Caretto, et al.. "Use of the 4K-3D ORBEYE Exoscope for Supermicrosurgical Lymphaticovenular Anastomosis: A Case Report.." Cureus, vol. 16, no. 10, 2024, pp. e71198.
PMID 39399276

Abstract

The evolution in microsurgery using high-definition three-dimensional (3D) cameras has provided the opportunity to replace conventional operating microscopes (OM), improving ergonomics for microsurgeons. Several 3D exoscope systems have already demonstrated good surgical field visualization in a 3D space in performing microvascular anastomosis with favorable maneuverability and non-inferiority compared to OM. We present the application of the 4K-3D ORBEYE system (Olympus Inc., Tokyo, Japan) in performing lymphaticovenular anastomosis to treat lower limb lymphedema and the challenges and tips to manage small vessels measuring <0.8 mm. This system provided a good intraoperative outcome with greater ergonomics and a non-inferiority magnification compared to traditional microscopes. Our findings need further studies to confirm the feasibility; however, the 4K-3D ORBEYE represents a valid possibility to assist microsurgeons in lymphatic surgery.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
시술 microsurgery 미세수술 dict 1
시술 microvascular 미세수술 dict 1
해부 lower limb lymphedema scispacy 1
약물 ORBEYE scispacy 1
질환 lower limb lymphedema C1866050
Lymphedema (lower limb)
scispacy 1
기타 Lymphaticovenular scispacy 1
기타 ORBEYE scispacy 1
기타 vessels scispacy 1
기타 lymphatic scispacy 1

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문