Ultrasonography for measuring rectus abdominis muscles diastasis.
Abstract
[PURPOSE] Preoperative imaging evaluation may be useful for determining the position of recti abdominis muscles before their correction. The purpose of this study is to evaluate the accuracy of ultrasonography to measure the width of rectus abdominis muscle diastasis.
[METHODS] Rectus diastasis was measured by ultrasonography preoperatively in 20 females. Rectus diastasis was measured in seven levels along the anterior rectus sheath by ultrasound after sustained deep inspiration and after expiration. Rectus diastasis, at the same levels, was also measured after its exposition during abdominoplasty by two independent observers, using a surgical compass. These values were compared using Wilcoxon's statistical text, for non independent values.
[RESULTS] There was no significant difference between the values obtained by ultrasound and those measured during surgery in the supra-umbilical levels and at the level of the umbilicus. However, below the umbilicus these values differed significantly, showing smaller values in the imaging evaluation.
[CONCLUSION] Ultrasonography is an accurate method to measure rectus diastasis above the umbilicus and at the umbilical level.
[METHODS] Rectus diastasis was measured by ultrasonography preoperatively in 20 females. Rectus diastasis was measured in seven levels along the anterior rectus sheath by ultrasound after sustained deep inspiration and after expiration. Rectus diastasis, at the same levels, was also measured after its exposition during abdominoplasty by two independent observers, using a surgical compass. These values were compared using Wilcoxon's statistical text, for non independent values.
[RESULTS] There was no significant difference between the values obtained by ultrasound and those measured during surgery in the supra-umbilical levels and at the level of the umbilicus. However, below the umbilicus these values differed significantly, showing smaller values in the imaging evaluation.
[CONCLUSION] Ultrasonography is an accurate method to measure rectus diastasis above the umbilicus and at the umbilical level.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | abdominoplasty
|
복부성형술 | dict | 1 | |
| 해부 | supra-umbilical
|
scispacy | 1 | ||
| 해부 | umbilical
|
scispacy | 1 | ||
| 합병증 | Rectus diastasis
|
scispacy | 1 | ||
| 합병증 | umbilicus
|
scispacy | 1 | ||
| 기타 | rectus abdominis muscles
|
scispacy | 1 | ||
| 기타 | recti abdominis muscles
|
scispacy | 1 | ||
| 기타 | rectus abdominis muscle
|
scispacy | 1 | ||
| 기타 | anterior rectus sheath
|
scispacy | 1 |
MeSH Terms
Abdominal Wall; Female; Humans; Intraoperative Complications; Preoperative Care; Rectus Abdominis; Reproducibility of Results; Statistics, Nonparametric; Ultrasonography
📑 인용 관계
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Case report of a rare soft tissue tuberculosis in a patient undergoing lipoabdominoplasty.
- What is the potential role of the nonopioid suzetrigine in pain management?
- Ex Vivo and In Vivo Histological Evaluation of a 3-μm Wavelength, 40-μm Spot Size Fractional Laser System for Dermatology.
- Correspondence on "Lymphatic pathway remodeling in the supraumbilical region after abdominoplasty: A prospective cohort study".
- Sculpting Success-The TULUANHA: Modified TULUA Lipo-Abdominoplasty in Post-Bariatric Body Contouring.