Ultrasound and Histologic Examination after Subcutaneous Injection of Two Volumizing Hyaluronic Acid Fillers: A Preliminary Study.
Abstract
[BACKGROUND] This study examined the influence of hyaluronic acid (HA) crosslinking technology on the ultrasound and histologic behavior of HA fillers designed for subcutaneous injection.
[METHODS] One subject received subcutaneous injections of 0.25 ml Cohesive Polydensified Matrix (CPM) and Vycross volumizing HA in tissue scheduled for abdominoplasty by bolus and retrograde fanning techniques. Ultrasound analyses were performed on days 0 and 8 and histologic analyses on days 0 and 21 after injection. A series of simple rheologic tests was also performed.
[RESULTS] Day 0 ultrasound images after bolus injection showed CPM and Vycross as hypoechogenic papules in the hypodermis. CPM appeared little changed after gentle massage, whereas Vycross appeared more hyperechogenic and diminished in size. Ultrasound images at day 8 were similar. On day 0, both gels appeared less hypoechogenic after retrograde fanning than after bolus injection. Vycross was interspersed with hyperechogenic areas (fibrous septa from the fat network structure) and unlike CPM became almost completely invisible after gentle massage. On day 8, CPM appeared as a hypoechogenic pool and Vycross as a long, thin rod. Day 0 histologic findings confirmed ultrasound results. Day 21 CPM histologic findings showed a discrete inflammatory reaction along the injection row after retrograde fanning. Vycross had a more pronounced inflammatory reaction, particularly after retrograde fanning, with macrophages and giant cells surrounding the implant. Rheologic tests showed CPM to have greater cohesivity and resistance to traction forces than Vycross.
[CONCLUSIONS] CPM HA volumizer appears to maintain greater tissue integrity than Vycross after subcutaneous injection with less inflammatory activity.
[METHODS] One subject received subcutaneous injections of 0.25 ml Cohesive Polydensified Matrix (CPM) and Vycross volumizing HA in tissue scheduled for abdominoplasty by bolus and retrograde fanning techniques. Ultrasound analyses were performed on days 0 and 8 and histologic analyses on days 0 and 21 after injection. A series of simple rheologic tests was also performed.
[RESULTS] Day 0 ultrasound images after bolus injection showed CPM and Vycross as hypoechogenic papules in the hypodermis. CPM appeared little changed after gentle massage, whereas Vycross appeared more hyperechogenic and diminished in size. Ultrasound images at day 8 were similar. On day 0, both gels appeared less hypoechogenic after retrograde fanning than after bolus injection. Vycross was interspersed with hyperechogenic areas (fibrous septa from the fat network structure) and unlike CPM became almost completely invisible after gentle massage. On day 8, CPM appeared as a hypoechogenic pool and Vycross as a long, thin rod. Day 0 histologic findings confirmed ultrasound results. Day 21 CPM histologic findings showed a discrete inflammatory reaction along the injection row after retrograde fanning. Vycross had a more pronounced inflammatory reaction, particularly after retrograde fanning, with macrophages and giant cells surrounding the implant. Rheologic tests showed CPM to have greater cohesivity and resistance to traction forces than Vycross.
[CONCLUSIONS] CPM HA volumizer appears to maintain greater tissue integrity than Vycross after subcutaneous injection with less inflammatory activity.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | subcutaneous
|
피하조직 | dict | 4 | |
| 재료 | ha
|
히알루론산 | dict | 4 | |
| 재료 | hyaluronic acid
|
히알루론산 | dict | 2 | |
| 시술 | abdominoplasty
|
복부성형술 | dict | 1 | |
| 해부 | hypodermis
|
피하조직 | dict | 1 | |
| 해부 | Matrix
|
scispacy | 1 | ||
| 해부 | tissue
|
scispacy | 1 | ||
| 해부 | macrophages
|
scispacy | 1 | ||
| 해부 | giant cells
|
scispacy | 1 | ||
| 합병증 | volumizing HA
|
scispacy | 1 | ||
| 합병증 | papules
|
scispacy | 1 | ||
| 합병증 | fibrous septa
|
scispacy | 1 | ||
| 약물 | CPM
→ Cohesive Polydensified Matrix
|
scispacy | 1 | ||
| 약물 | [RESULTS] Day
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS] CPM HA volumizer
|
scispacy | 1 | ||
| 질환 | hypoechogenic
|
C4477002
Decreased hepatic echogenicity
|
scispacy | 1 | |
| 질환 | Volumizing Hyaluronic Acid
|
scispacy | 1 | ||
| 질환 | CPM
→ Cohesive Polydensified Matrix
|
scispacy | 1 | ||
| 기타 | HA fillers
|
scispacy | 1 | ||
| 기타 | fat network
|
scispacy | 1 |
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
같은 제1저자의 인용 많은 논문 (4)
- Comprehensive Evaluation of Injectability Attributes in OxiFree™ Dermal Fillers: MaiLi Product Variants and Clinical Case Reports.
- Clinical Perspectives on the Injectability of Cross-Linked Hyaluronic Acid Dermal Fillers: A Standardized Methodology for Commercial Product Benchmarking with Inter-Injector Assessments.
- Hand Rejuvenation With A Hyaluronic Acid-Based Dermal Filler: A 12-Month Clinical Follow-Up Case Series.
- Quantifying Depth of Injection of Hyaluronic Acid in the Dermis: Data from Clinical, Laboratory, and Ultrasound Settings.
관련 논문
- Penetrating globe injury following periocular hyaluronic acid filler injection: A case report.
- Choroidal ischemia after self-injection of hyaluronic acid filler.
- Case report of a rare soft tissue tuberculosis in a patient undergoing lipoabdominoplasty.
- What is the potential role of the nonopioid suzetrigine in pain management?
- Intra-articular therapies for synovial joint dysfunction: a comprehensive integrative review.