Comparison of skin biopsy sample processing and storage methods on high dimensional immune gene expression using the Nanostring nCounter system.
Abstract
[BACKGROUND] Digital multiplex gene expression profiling is overcoming the limitations of many tissue-processing and RNA extraction techniques for the reproducible and quantitative molecular classification of disease. We assessed the effect of different skin biopsy collection/storage conditions on mRNA quality and quantity and the NanoString nCounter™ System's ability to reproducibly quantify the expression of 730 immune genes from skin biopsies.
[METHODS] Healthy human skin punch biopsies (n = 6) obtained from skin sections from four patients undergoing routine abdominoplasty were subject to one of several collection/storage protocols, including: i) snap freezing in liquid nitrogen and transportation on dry ice; ii) RNAlater (ThermoFisher) for 24 h at room temperature then stored at - 80 °C; iii) formalin fixation with further processing for FFPE blocks; iv) DNA/RNA shield (Zymo) stored and shipped at room temperature; v) placed in TRIzol then stored at - 80 °C; vi) saline without RNAse for 24 h at room temperature then stored at - 80 °C. RNA yield and integrity was assessed following extraction via NanoDrop, QuantiFluor with RNA specific dye and a Bioanalyser (LabChip24, PerkinElmer). Immune gene expression was analysed using the NanoString Pancancer Immune Profiling Panel containing 730 genes.
[RESULTS] Except for saline, all protocols yielded total RNA in quantities/qualities that could be analysed by NanoString nCounter technology, although the quality of the extracted RNA varied widely. Mean RNA integrity was highest from samples that were placed in RNALater (RQS 8.2 ± 1.15), with integrity lowest from the saline stored sample (RQS < 2). There was a high degree of reproducibility in the expression of immune genes between all samples with the exception of saline, with the number of detected genes at counts < 100, between 100 and 1000 and > 10,000 similar across extraction protocols.
[CONCLUSIONS] A variety of processing methods can be used for digital immune gene expression profiling in mRNA extracted from skin that are comparable to snap frozen skin specimens, providing skin cancer clinicians greater opportunity to supply skin specimens to tissue banks. NanoString nCounter technology can determine gene expression in skin biopsy specimens with a high degree of sensitivity despite lower RNA yields and processing methods that may generate poorer quality RNA. The increased sensitivity of digital gene expression profiling continues to expand molecular pathology profiling of disease.
[METHODS] Healthy human skin punch biopsies (n = 6) obtained from skin sections from four patients undergoing routine abdominoplasty were subject to one of several collection/storage protocols, including: i) snap freezing in liquid nitrogen and transportation on dry ice; ii) RNAlater (ThermoFisher) for 24 h at room temperature then stored at - 80 °C; iii) formalin fixation with further processing for FFPE blocks; iv) DNA/RNA shield (Zymo) stored and shipped at room temperature; v) placed in TRIzol then stored at - 80 °C; vi) saline without RNAse for 24 h at room temperature then stored at - 80 °C. RNA yield and integrity was assessed following extraction via NanoDrop, QuantiFluor with RNA specific dye and a Bioanalyser (LabChip24, PerkinElmer). Immune gene expression was analysed using the NanoString Pancancer Immune Profiling Panel containing 730 genes.
[RESULTS] Except for saline, all protocols yielded total RNA in quantities/qualities that could be analysed by NanoString nCounter technology, although the quality of the extracted RNA varied widely. Mean RNA integrity was highest from samples that were placed in RNALater (RQS 8.2 ± 1.15), with integrity lowest from the saline stored sample (RQS < 2). There was a high degree of reproducibility in the expression of immune genes between all samples with the exception of saline, with the number of detected genes at counts < 100, between 100 and 1000 and > 10,000 similar across extraction protocols.
[CONCLUSIONS] A variety of processing methods can be used for digital immune gene expression profiling in mRNA extracted from skin that are comparable to snap frozen skin specimens, providing skin cancer clinicians greater opportunity to supply skin specimens to tissue banks. NanoString nCounter technology can determine gene expression in skin biopsy specimens with a high degree of sensitivity despite lower RNA yields and processing methods that may generate poorer quality RNA. The increased sensitivity of digital gene expression profiling continues to expand molecular pathology profiling of disease.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | abdominoplasty
|
복부성형술 | dict | 1 | |
| 해부 | skin
|
scispacy | 1 | ||
| 해부 | tissue
|
scispacy | 1 | ||
| 합병증 | skin biopsy
|
scispacy | 1 | ||
| 합병증 | skin sections
|
scispacy | 1 | ||
| 약물 | nitrogen
|
C0028158
nitrogen
|
scispacy | 1 | |
| 약물 | [BACKGROUND] Digital
|
scispacy | 1 | ||
| 약물 | RNAse
|
scispacy | 1 | ||
| 약물 | saline
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS] A
|
scispacy | 1 | ||
| 질환 | skin cancer
|
C0007114
Malignant neoplasm of skin
|
scispacy | 1 | |
| 질환 | disease
|
scispacy | 1 | ||
| 질환 | FFPE
|
scispacy | 1 | ||
| 질환 | LabChip24
|
scispacy | 1 | ||
| 질환 | samples
|
scispacy | 1 | ||
| 기타 | skin biopsies
|
scispacy | 1 | ||
| 기타 | human skin punch biopsies
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 |
MeSH Terms
Biopsy; Gene Expression Profiling; Humans; RNA Stability; RNA, Messenger; Skin; Specimen Handling; Tissue Preservation
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Case report of a rare soft tissue tuberculosis in a patient undergoing lipoabdominoplasty.
- What is the potential role of the nonopioid suzetrigine in pain management?
- Ex Vivo and In Vivo Histological Evaluation of a 3-μm Wavelength, 40-μm Spot Size Fractional Laser System for Dermatology.
- Correspondence on "Lymphatic pathway remodeling in the supraumbilical region after abdominoplasty: A prospective cohort study".
- Sculpting Success-The TULUANHA: Modified TULUA Lipo-Abdominoplasty in Post-Bariatric Body Contouring.