Analysis of 30 breast implant rupture cases.
Abstract
Breast implants used for augmentation mammoplasty or breast reconstruction could rupture from various causes such as trauma or spontaneous failure. The objectives of this study were to investigate the relationships between the causes of implant rupture and the degree of capsular contracture, and then to evaluate the relative efficacies of specific signs on magnetic resonance imaging (MRI) known to be beneficial for diagnosing the rupture. A retrospective review identified patients with prosthetic implant rupture or impending rupture treated by the senior author. The 30 cases of implant rupture available for review were classified into two groups: intracapsular and extracapsular ruptures. The 30 cases of breast implant ruptures were analyzed with respect to the clinical symptoms and signs, the causes of rupture, the degree of capsular contracture, and therapeutic plans. Among the 30 cases, 14 patients who had undergone MRI during the diagnostic period were analyzed with respect to the relationships between MRI readings and operative findings. Spontaneous rupture of membranes was most common (80%), followed by failure because of trauma (7%) and valve or implant base (4%). The symptoms during implant rupture were contour deformity, palpated mass-like lesions, pain, and focal inflammation. According to the analysis of specific MRI signs, the sensitivity and specificity of the linguine sign were 87% and 100%, respectively, for intracapsular rupture. For extracapsular rupture, the sensitivity and specificity of the linguine sign were, respectively, 67% and 75%. The sensitivity and specificity of the rat-tail sign and tear drop sign were 14% and 50%, respectively. Breast implant rupture was correlated with the degree of capsular contracture in our study. Among the various specific MRI signs used in diagnosing the rupture, the linguine sign was reliable and had a high sensitivity and specificity, especially in cases of intracapsular rupture. On the other hand, the rat-tail and tear drop signs were nonspecific signs for diagnosing the rupture of breast implant.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 6 | |
| 합병증 | implant rupture
|
보형물 파열 | dict | 4 | |
| 합병증 | capsular contracture
|
피막구축 | dict | 3 | |
| 합병증 | breast implant rupture
|
보형물 파열 | dict | 2 | |
| 시술 | augmentation mammoplasty
|
유방성형술 | dict | 1 | |
| 해부 | intracapsular
|
scispacy | 1 | ||
| 해부 | extracapsular ruptures
|
scispacy | 1 | ||
| 해부 | membranes
|
scispacy | 1 | ||
| 해부 | focal
|
scispacy | 1 | ||
| 해부 | extracapsular
|
scispacy | 1 | ||
| 해부 | intracapsular rupture.
|
scispacy | 1 | ||
| 해부 | tear
|
scispacy | 1 | ||
| 합병증 | breast implant ruptures
|
scispacy | 1 | ||
| 합병증 | mass-like lesions
|
scispacy | 1 | ||
| 질환 | rupture
|
C3203359
Rupture
|
scispacy | 1 | |
| 질환 | trauma
|
C0043251
Wounds and Injuries
|
scispacy | 1 | |
| 질환 | breast implant ruptures
|
C0405491
Rupture of breast implant
|
scispacy | 1 | |
| 질환 | pain
|
C0030193
Pain
|
scispacy | 1 | |
| 질환 | intracapsular rupture
|
scispacy | 1 | ||
| 질환 | breast implant
|
C0178391
breast implant procedure
|
scispacy | 1 | |
| 기타 | patients
|
scispacy | 1 | ||
| 기타 | rat-tail
|
scispacy | 1 |
MeSH Terms
Adult; Breast Implants; Female; Humans; Middle Aged; Postoperative Complications; Reoperation; Retrospective Studies
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.