A comparison of outcomes involving highly cohesive, form-stable breast implants from two manufacturers in patients undergoing primary breast augmentation.
Abstract
[BACKGROUND] Although there have been reports of single-surgeon outcomes with highly cohesive, form-stable silicone gel implants in women undergoing primary breast augmentation, there has been only one study published that compares the outcomes between the Allergan 410 and the Mentor CPG devices.
[OBJECTIVES] The goal of the study is to compare outcomes in each cohort and to determine if quality systems and processes would have an impact on lowering the surgical revision rate, as compared to published reports for round gel implants and form-stable implants.
[METHODS] Patients selected for the study were required to meet predefined inclusion criteria and general indications for breast augmentation. All subjects were treated uniformly with extensive informed consent prior to surgery. The entire process of breast augmentation (patient assessment, informed consent, the surgical procedure itself and postoperative instructions) was identical between the two groups. Patients were not randomized, as the studies did not start at the same time. The process for management of each patient was based on adaptation of the Toyota Production System and Lean Manufacturing, with emphasis on achieving operational excellence in the use of planning templates for surgery, including accurate management of patient expectations regarding size outcome.
[RESULTS] Outcomes data included physical breast measurements, quality of life metrics, and patient/surgeon satisfaction assessment. Adverse events were compared against published data for breast implants. Follow-up ranged between 20-77 months (Allergan 410) and 16-77 months (Mentor CPG). The outcome data indicate that these devices produce natural-appearing breasts with extremely low aggregate reoperation rate (4.2%). Only 0.8% of the reoperations were attributable to surgeon-related factors. There were no reoperations to correct mismanaged size expectations during the course of each study. There were 13 pregnancies and no difficulties with lactation were reported. Rippling (lateral/medial, palpable and/or visible) was encountered in both cohorts. The Mentor CPG cohort had a fivefold greater incidence of rippling (37.3% versus 7.6% in Allergan 410 cohort). This was highly statistically significant (P < .001).
[CONCLUSIONS] Provided that there is adherence to core principles and avoidance of errors in planning, patient expectations, and surgery, highly cohesive, form-stable breast implants can deliver excellent long term outcomes in primary breast augmentation in a diverse patient population. The impact of quality processes such as Toyota Production System and Lean Manufacturing was substantive in delivering operational excellence in primary breast augmentation.
[OBJECTIVES] The goal of the study is to compare outcomes in each cohort and to determine if quality systems and processes would have an impact on lowering the surgical revision rate, as compared to published reports for round gel implants and form-stable implants.
[METHODS] Patients selected for the study were required to meet predefined inclusion criteria and general indications for breast augmentation. All subjects were treated uniformly with extensive informed consent prior to surgery. The entire process of breast augmentation (patient assessment, informed consent, the surgical procedure itself and postoperative instructions) was identical between the two groups. Patients were not randomized, as the studies did not start at the same time. The process for management of each patient was based on adaptation of the Toyota Production System and Lean Manufacturing, with emphasis on achieving operational excellence in the use of planning templates for surgery, including accurate management of patient expectations regarding size outcome.
[RESULTS] Outcomes data included physical breast measurements, quality of life metrics, and patient/surgeon satisfaction assessment. Adverse events were compared against published data for breast implants. Follow-up ranged between 20-77 months (Allergan 410) and 16-77 months (Mentor CPG). The outcome data indicate that these devices produce natural-appearing breasts with extremely low aggregate reoperation rate (4.2%). Only 0.8% of the reoperations were attributable to surgeon-related factors. There were no reoperations to correct mismanaged size expectations during the course of each study. There were 13 pregnancies and no difficulties with lactation were reported. Rippling (lateral/medial, palpable and/or visible) was encountered in both cohorts. The Mentor CPG cohort had a fivefold greater incidence of rippling (37.3% versus 7.6% in Allergan 410 cohort). This was highly statistically significant (P < .001).
[CONCLUSIONS] Provided that there is adherence to core principles and avoidance of errors in planning, patient expectations, and surgery, highly cohesive, form-stable breast implants can deliver excellent long term outcomes in primary breast augmentation in a diverse patient population. The impact of quality processes such as Toyota Production System and Lean Manufacturing was substantive in delivering operational excellence in primary breast augmentation.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 10 | |
| 시술 | breast augmentation
|
유방성형술 | dict | 6 | |
| 해부 | Lean
|
scispacy | 1 | ||
| 해부 | breasts
|
scispacy | 1 | ||
| 해부 | lateral/medial
|
scispacy | 1 | ||
| 약물 | silicone
|
C0037114
silicones
|
scispacy | 1 | |
| 약물 | form-stable
|
scispacy | 1 | ||
| 약물 | [BACKGROUND]
|
scispacy | 1 | ||
| 약물 | [OBJECTIVES]
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS]
|
scispacy | 1 | ||
| 질환 | primary breast augmentation
|
scispacy | 1 | ||
| 질환 | patient/surgeon
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 | ||
| 기타 | women
|
scispacy | 1 | ||
| 기타 | form-stable
|
scispacy | 1 | ||
| 기타 | patient
|
scispacy | 1 |
MeSH Terms
Adolescent; Adult; Breast Implantation; Breast Implants; Cohort Studies; Equipment Design; Female; Follow-Up Studies; Humans; Patient Satisfaction; Quality of Life; Reoperation; Treatment Outcome; Young Adult
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.