Breast augmentation with extra-projected and high-cohesive Dual-Gel Prosthesis 510: a prospective study of 75 consecutive cases for a new method (the Zenith system).
Abstract
[BACKGROUND] Extra-projected Natrelle 510 belongs to a new generation of silicone breast implants. A single-surgeon prospective study set out to investigate the device's features, outcomes, and complications, and devise a proper measurement method based on the zenith system.
[METHODS] From December 2004 to June 2010, 75 subjects (150 implants) were enrolled in four cohorts: primary augmentation (66.7%), primary mastopexy augmentation (17.3%), secondary implant exchange (9.3%), and secondary implant exchange+pexy (6.7%). The system used to select the implant correlated the point of maximal projection (vertex-zenith) and nipple position. The surgical approach included (1) narrow pocket, preferably dual-plane; (2) device vertex 1-2.5 cm beneath nipple (zenith range=12°-23°) related to a nipple-inframammary fold distance of 7-7.5 cm at maximal stretch and a nipple-sternum/lower-pole line distance of 4-5 cm; (3) inframammary fold lowered minimally; (4) vertex at ±1 cm from the midbreast meridian crossing the nipple; and (5) maximizing the biomechanical effects between soft-tissue dynamics, firmer gel pressure, and pectoralis major counterpressure to expand the lower skin (dynamic tension).
[RESULTS] Mean follow-up was 26.5 months (range=6-72); in 20 subjects; follow-up was over 3 years (average=50 months) with a 90.8% patient satisfaction rate. This rate was lower in patients with preoperative ptosis. There was inframammary preservation with 60% of the implants and modification in 40% (0.80±0.45 cm). The overall complication rate per implant was 16.6% and included wound healing/scarring (7%), malrotation (2.6%, only 1% after primary augmentation), rippling (2%), capsular contracture (1.3%), and bottoming-out (0.6%). The revision rate was 6%, of which 3.3% were pocket revisions. Greater skills are required through the learning curve, patient education, case selection, planning using the nipple-vertex relationship (the zenith system), and improved surgical manipulation. Indications and contraindications were analyzed. Cosmetic results were compliant with different breast shapes, and excellent for the breast with poor projection, in thin subjects, and those with low BMI. Ptotic breast should require a larger amount of pexy, 510 did not lift the breast enough.
[CONCLUSION] Based on vertex-nipple distance, dynamic tension, and skin extensibility, this new approach gives guidelines and methods to perform breast augmentation with extra-projected implants.
[LEVEL OF EVIDENCE III] This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at www.springer.com/00266.
[METHODS] From December 2004 to June 2010, 75 subjects (150 implants) were enrolled in four cohorts: primary augmentation (66.7%), primary mastopexy augmentation (17.3%), secondary implant exchange (9.3%), and secondary implant exchange+pexy (6.7%). The system used to select the implant correlated the point of maximal projection (vertex-zenith) and nipple position. The surgical approach included (1) narrow pocket, preferably dual-plane; (2) device vertex 1-2.5 cm beneath nipple (zenith range=12°-23°) related to a nipple-inframammary fold distance of 7-7.5 cm at maximal stretch and a nipple-sternum/lower-pole line distance of 4-5 cm; (3) inframammary fold lowered minimally; (4) vertex at ±1 cm from the midbreast meridian crossing the nipple; and (5) maximizing the biomechanical effects between soft-tissue dynamics, firmer gel pressure, and pectoralis major counterpressure to expand the lower skin (dynamic tension).
[RESULTS] Mean follow-up was 26.5 months (range=6-72); in 20 subjects; follow-up was over 3 years (average=50 months) with a 90.8% patient satisfaction rate. This rate was lower in patients with preoperative ptosis. There was inframammary preservation with 60% of the implants and modification in 40% (0.80±0.45 cm). The overall complication rate per implant was 16.6% and included wound healing/scarring (7%), malrotation (2.6%, only 1% after primary augmentation), rippling (2%), capsular contracture (1.3%), and bottoming-out (0.6%). The revision rate was 6%, of which 3.3% were pocket revisions. Greater skills are required through the learning curve, patient education, case selection, planning using the nipple-vertex relationship (the zenith system), and improved surgical manipulation. Indications and contraindications were analyzed. Cosmetic results were compliant with different breast shapes, and excellent for the breast with poor projection, in thin subjects, and those with low BMI. Ptotic breast should require a larger amount of pexy, 510 did not lift the breast enough.
[CONCLUSION] Based on vertex-nipple distance, dynamic tension, and skin extensibility, this new approach gives guidelines and methods to perform breast augmentation with extra-projected implants.
[LEVEL OF EVIDENCE III] This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at www.springer.com/00266.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 7 | |
| 시술 | breast augmentation
|
유방성형술 | dict | 2 | |
| 시술 | mastopexy
|
유방성형술 | dict | 1 | |
| 해부 | nipple
|
scispacy | 1 | ||
| 해부 | soft-tissue
|
scispacy | 1 | ||
| 해부 | pectoralis
|
scispacy | 1 | ||
| 해부 | skin
|
scispacy | 1 | ||
| 해부 | inframammary
|
scispacy | 1 | ||
| 합병증 | wound
|
scispacy | 1 | ||
| 합병증 | capsular contracture
|
피막구축 | dict | 1 | |
| 약물 | [BACKGROUND] Extra-projected Natrelle 510
|
scispacy | 1 | ||
| 질환 | silicone breast
|
scispacy | 1 | ||
| 질환 | malrotation
|
C0221210
Congenital malrotation of intestine
|
scispacy | 1 | |
| 질환 | nipple-vertex
|
scispacy | 1 | ||
| 질환 | Ptotic breast
|
scispacy | 1 | ||
| 기타 | nipple
|
scispacy | 1 | ||
| 기타 | vertex-nipple
|
scispacy | 1 |
MeSH Terms
Adult; Breast Diseases; Breast Implantation; Breast Implants; Cohort Studies; Esthetics; Female; Follow-Up Studies; Humans; Italy; Middle Aged; Minimally Invasive Surgical Procedures; Patient Satisfaction; Postoperative Complications; Prospective Studies; Prosthesis Design; Silicone Gels; Treatment Outcome; Young Adult
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.