Periareolar extra-glandular breast augmentation.
Abstract
[BACKGROUND] Breast augmentation is the most frequent procedure performed according to the 2009 Quick Facts report of the American Society of Plastic Surgeons. This study presents the periareolar extra-glandular breast augmentation.
[METHODS] From 2004 to 2010 among 32 female patients, peri-areolar incision was performed for breast augmentation. Dissection was performed in subcutaneous plane towards the inferior pole to reach the inframammary fold and was continued in the upwards direction in the subglandular plane to create a pocket. Once the implant of desired size was in place, three sutures fixed the inframammary fold. The skin incision was closed using 4-0 non-absorbable suture.
[RESULTS] The mean age of patients was 30.7 years and the average incision length was 5.8 cm. 59.4% of patients had an implant size of more than 305 ml and less than 10% of patients had drains which were removed the next morning. All patients were followed regularly and no case of implant infection or removal was seen and only 2 patients had slight stretched scars. In one patient, the implant was high riding and no case of the capsular contracture was noticed. Changes in sensation were noted in 21.9% patients at 3 month interval which was reduced to 6.3% at 6 months interval. Similarly no case of rippling or other visible deformity was noted.
[CONCLUSION] The extra-glandular periareolar approach for the breast augmentation can be a good option with few side-effects even it is associated with a higher level of surgical expertise.
[METHODS] From 2004 to 2010 among 32 female patients, peri-areolar incision was performed for breast augmentation. Dissection was performed in subcutaneous plane towards the inferior pole to reach the inframammary fold and was continued in the upwards direction in the subglandular plane to create a pocket. Once the implant of desired size was in place, three sutures fixed the inframammary fold. The skin incision was closed using 4-0 non-absorbable suture.
[RESULTS] The mean age of patients was 30.7 years and the average incision length was 5.8 cm. 59.4% of patients had an implant size of more than 305 ml and less than 10% of patients had drains which were removed the next morning. All patients were followed regularly and no case of implant infection or removal was seen and only 2 patients had slight stretched scars. In one patient, the implant was high riding and no case of the capsular contracture was noticed. Changes in sensation were noted in 21.9% patients at 3 month interval which was reduced to 6.3% at 6 months interval. Similarly no case of rippling or other visible deformity was noted.
[CONCLUSION] The extra-glandular periareolar approach for the breast augmentation can be a good option with few side-effects even it is associated with a higher level of surgical expertise.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | breast augmentation
|
유방성형술 | dict | 5 | |
| 해부 | breast
|
유방 | dict | 5 | |
| 해부 | subcutaneous
|
피하조직 | dict | 1 | |
| 해부 | peri-areolar incision
|
scispacy | 1 | ||
| 해부 | inframammary
|
scispacy | 1 | ||
| 해부 | subglandular
|
scispacy | 1 | ||
| 해부 | skin
|
scispacy | 1 | ||
| 합병증 | infection
|
감염 | dict | 1 | |
| 합병증 | capsular contracture
|
피막구축 | dict | 1 | |
| 합병증 | periareolar extra-glandular breast
|
scispacy | 1 | ||
| 합병증 | subcutaneous plane
|
scispacy | 1 | ||
| 약물 | [BACKGROUND] Breast
|
scispacy | 1 | ||
| 약물 | [RESULTS]
|
scispacy | 1 | ||
| 질환 | Periareolar extra-glandular breast augmentation
|
scispacy | 1 | ||
| 기타 | Periareolar extra-glandular
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 | ||
| 기타 | patient
|
scispacy | 1 | ||
| 기타 | extra-glandular periareolar
|
scispacy | 1 |
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Penetrating globe injury following periocular hyaluronic acid filler injection: A case report.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.