A new orthosis reduces pain and mechanical forces in prone position in women with augmented or natural breast tissue: a pilot study.
Abstract
[BACKGROUND] Breast augmentation, post-mastectomy patients as well as some women with natural breast tissue, and lactating, women often experience discomfort in prone activities. Our study, for the first time, examines pain levels, mechanical force and peak pressure in natural, reconstructed and augmented breast tissues with and without a new orthosis designed for reduction of displacement, compression and loading forces through the breast tissue during prone activities.
[METHODS] Twelve females with natural, lactating or augmented breast tissue, and cup-sizes C-F volunteered for the study. Pain perception was measured using an 11-point visual-analogue-scale without and with different sizes/textures of the orthosis. Magnetic-Resonance-Imaging captured segmental transverse and para-sagittal mid-breast views, and provided linear measurements of breast tissue displacement and deformation. Capacitance-pliance® sensorstrips were used to measure force and pressure between the breast tissue and the surface of a standard treatment table. Measurements were taken whilst the participants were load bearing in prone positions with and without the orthosis.
[RESULTS] The new orthosis significantly reduced pain and mechanical forces in participants with natural or augmented breast tissue with cup-sizes C-F. Larger orthotic sizes were correlated with greater reduction in pain and mechanical forces, with all participants reporting no pain with the largest size orthotic. A size-3 orthotic decreased load on the breast tissue by 82% and reduced peak pressure by 42%. The same orthotic decreased medio-lateral spread of breast tissue and implant whilst increasing height.
[CONCLUSIONS] The new orthosis significantly reduced pain and mechanical forces in all women with natural or augmented tissues. Results are of clinical significance, as reduced mechanical forces are associated with greater comfort and reduced pressure and displacement which may lower the probability of breast implant complication. In clinical settings the orthosis is recommended for all augmentation patients when undergoing prone treatment by therapists and clinicians for improved comfort and safety.
[METHODS] Twelve females with natural, lactating or augmented breast tissue, and cup-sizes C-F volunteered for the study. Pain perception was measured using an 11-point visual-analogue-scale without and with different sizes/textures of the orthosis. Magnetic-Resonance-Imaging captured segmental transverse and para-sagittal mid-breast views, and provided linear measurements of breast tissue displacement and deformation. Capacitance-pliance® sensorstrips were used to measure force and pressure between the breast tissue and the surface of a standard treatment table. Measurements were taken whilst the participants were load bearing in prone positions with and without the orthosis.
[RESULTS] The new orthosis significantly reduced pain and mechanical forces in participants with natural or augmented breast tissue with cup-sizes C-F. Larger orthotic sizes were correlated with greater reduction in pain and mechanical forces, with all participants reporting no pain with the largest size orthotic. A size-3 orthotic decreased load on the breast tissue by 82% and reduced peak pressure by 42%. The same orthotic decreased medio-lateral spread of breast tissue and implant whilst increasing height.
[CONCLUSIONS] The new orthosis significantly reduced pain and mechanical forces in all women with natural or augmented tissues. Results are of clinical significance, as reduced mechanical forces are associated with greater comfort and reduced pressure and displacement which may lower the probability of breast implant complication. In clinical settings the orthosis is recommended for all augmentation patients when undergoing prone treatment by therapists and clinicians for improved comfort and safety.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 13 | |
| 시술 | breast augmentation
|
유방성형술 | dict | 1 | |
| 해부 | breast tissues
|
scispacy | 1 | ||
| 해부 | breast tissue
|
scispacy | 1 | ||
| 해부 | tissues
|
scispacy | 1 | ||
| 약물 | [BACKGROUND] Breast
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS]
|
scispacy | 1 | ||
| 질환 | orthosis
|
C0006086
Braces-Orthopedic appliances
|
scispacy | 1 | |
| 질환 | pain
|
C0030193
Pain
|
scispacy | 1 | |
| 질환 | breast implant
|
C0178391
breast implant procedure
|
scispacy | 1 | |
| 질환 | breast tissue
|
scispacy | 1 | ||
| 질환 | post-mastectomy patients
|
scispacy | 1 | ||
| 질환 | natural breast tissue
|
scispacy | 1 | ||
| 기타 | women
|
scispacy | 1 | ||
| 기타 | participants
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 |
MeSH Terms
Adult; Body Mass Index; Breast; Breast Feeding; Breast Implants; Chi-Square Distribution; Cohort Studies; Equipment Design; Female; Humans; Lactation; Mammaplasty; Middle Aged; Organ Size; Orthotic Devices; Pain; Pain Measurement; Patient Satisfaction; Pilot Projects; Prone Position; Stress, Mechanical; Treatment Outcome; Young Adult
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.