Conical polyurethane implants: an uplifting augmentation.
Abstract
[BACKGROUND] Polyurethane-coated conical implants were introduced by Silimed (US distributor: Sientra, Santa Barbara, California) in 2008 and offer an alternative to round or anatomically shaped implants. By their design and volume distribution, they naturally create central volume and give a reasonable fullness to the upper pole while lifting some ptotic breasts, thus avoiding the need for classical mastopexy.
[OBJECTIVES] The authors discuss the advantages of conical implants as an alternative to conventional silicone implants for women with breast ptosis.
[METHODS] In the 2-year period between December 2010 and December 2012, a consecutive series of 302 women underwent implant-based breast surgery procedures (236 primary augmentations, 59 revisions, and 7 mastopexy-augmentations) with conical polyurethane devices. Implant volumes ranged from 225 to 560 cc, with low- to medium-profile devices predominating. No extra-high-profile implants were used. Only 1 patient had a drain inserted on completion of a revision augmentation.
[RESULTS] There were no infections (0%) and no wound dehiscence (0%). Four cases required reoperation (1.3%). Patient satisfaction scores were universally high (average, 9.94/10). There have been no capsular contractures to date, but follow-up is short.
[CONCLUSION] The modern conical, polyurethane implant has many advantages over the conventional round or anatomically shaped implants and offers patients an ideal compromise between volume, natural upper pole fullness, and a lift without mastopexy scars.
[OBJECTIVES] The authors discuss the advantages of conical implants as an alternative to conventional silicone implants for women with breast ptosis.
[METHODS] In the 2-year period between December 2010 and December 2012, a consecutive series of 302 women underwent implant-based breast surgery procedures (236 primary augmentations, 59 revisions, and 7 mastopexy-augmentations) with conical polyurethane devices. Implant volumes ranged from 225 to 560 cc, with low- to medium-profile devices predominating. No extra-high-profile implants were used. Only 1 patient had a drain inserted on completion of a revision augmentation.
[RESULTS] There were no infections (0%) and no wound dehiscence (0%). Four cases required reoperation (1.3%). Patient satisfaction scores were universally high (average, 9.94/10). There have been no capsular contractures to date, but follow-up is short.
[CONCLUSION] The modern conical, polyurethane implant has many advantages over the conventional round or anatomically shaped implants and offers patients an ideal compromise between volume, natural upper pole fullness, and a lift without mastopexy scars.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | mastopexy
|
유방성형술 | dict | 3 | |
| 해부 | breast
|
유방 | dict | 2 | |
| 합병증 | wound
|
scispacy | 1 | ||
| 합병증 | wound dehiscence
|
상처열개 | dict | 1 | |
| 약물 | silicone
|
C0037114
silicones
|
scispacy | 1 | |
| 약물 | [BACKGROUND] Polyurethane-coated conical implants were
|
scispacy | 1 | ||
| 약물 | [OBJECTIVES]
|
scispacy | 1 | ||
| 질환 | fullness
|
C0439650
Fullness
|
scispacy | 1 | |
| 질환 | ptotic breasts
|
scispacy | 1 | ||
| 질환 | breast ptosis
|
C2233848
Ptosis of breast
|
scispacy | 1 | |
| 질환 | infections
|
C0851162
Infections of musculoskeletal system
|
scispacy | 1 | |
| 질환 | upper pole fullness
|
scispacy | 1 | ||
| 질환 | implant-based breast
|
scispacy | 1 | ||
| 기타 | Silimed
|
scispacy | 1 | ||
| 기타 | women
|
scispacy | 1 | ||
| 기타 | patient
|
scispacy | 1 | ||
| 기타 | capsular contractures
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 |
MeSH Terms
Adult; Breast Implantation; Breast Implants; Female; Humans; Middle Aged; Patient Satisfaction; Polyurethanes; Prospective Studies; Prosthesis Design; Reoperation; Surveys and Questionnaires; Treatment Outcome; Young Adult
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.