Longitudinal Ultrasound Study of Breast Implant Rupture Over a Six-Year Interval.
Abstract
[BACKGROUND] Silicone gel-filled implants as opposed to saline-filled breast implants are the most commonly used breast implants in Europe, and this has recently also become the case in the United States. Modern implants have a multiple layer silicone shell and high to very high levels of cohesive silicone gel inside. Although breast magnetic resonance imaging is at present considered the gold standard imaging method for breast implant rupture detection, breast ultrasound (US) imaging is still the first-step investigation in Europe. The aim of this study was to verify whether or not the stepladder sign at US is still associated to intracapsular rupture among the last generation silicone breast implant.
[MATERIALS AND METHODS] In this study, 156 patients presenting for breast augmentation, mastopexy with implants and breast reconstruction for a total number of 303 breast implants inserted were enrolled. A preoperative breast ultrasonography was performed, and patients underwent a routine US scan every 6 months for 24 months to evaluate the implant status. A final US evaluation 6 years after implantation was also performed.
[RESULTS] Stepladder signs were seen at 6 years in 170 implants (56%) of the examined implants at US scan, and only 2 implants showed signs of possible rupture because of severe distortion of the implant profile with or without external silicone collection. A third ruptured implant was detected at magnetic resonance imaging by the presence of breach of the shell at the posterior surface of the implant with small external silicon collection and was eventually confirmed at surgery. Therefore, the overall rupture rate found at the United States at 6 years was about 1% (3 of 303 implants). According to our findings, the stepladder sign at the United States is no longer associated to intracapsular rupture.
[CONCLUSIONS] Plastic surgeons, patients, and financial departments of hospitals would also be delighted to know that surgeons should not take patients back to theater for implant explantation when aging signs are not associated with a visible breach of the implant shell or external silicone collections.
[MATERIALS AND METHODS] In this study, 156 patients presenting for breast augmentation, mastopexy with implants and breast reconstruction for a total number of 303 breast implants inserted were enrolled. A preoperative breast ultrasonography was performed, and patients underwent a routine US scan every 6 months for 24 months to evaluate the implant status. A final US evaluation 6 years after implantation was also performed.
[RESULTS] Stepladder signs were seen at 6 years in 170 implants (56%) of the examined implants at US scan, and only 2 implants showed signs of possible rupture because of severe distortion of the implant profile with or without external silicone collection. A third ruptured implant was detected at magnetic resonance imaging by the presence of breach of the shell at the posterior surface of the implant with small external silicon collection and was eventually confirmed at surgery. Therefore, the overall rupture rate found at the United States at 6 years was about 1% (3 of 303 implants). According to our findings, the stepladder sign at the United States is no longer associated to intracapsular rupture.
[CONCLUSIONS] Plastic surgeons, patients, and financial departments of hospitals would also be delighted to know that surgeons should not take patients back to theater for implant explantation when aging signs are not associated with a visible breach of the implant shell or external silicone collections.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 11 | |
| 합병증 | breast implant rupture
|
보형물 파열 | dict | 2 | |
| 시술 | breast augmentation
|
유방성형술 | dict | 1 | |
| 시술 | mastopexy
|
유방성형술 | dict | 1 | |
| 재료 | silicone breast implant
|
실리콘 보형물 | dict | 1 | |
| 약물 | Silicone
|
C0037114
silicones
|
scispacy | 1 | |
| 약물 | [BACKGROUND] Silicone gel-filled
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS] Plastic
|
scispacy | 1 | ||
| 질환 | intracapsular rupture
|
scispacy | 1 | ||
| 질환 | rupture
|
C3203359
Rupture
|
scispacy | 1 | |
| 질환 | breast magnetic
|
scispacy | 1 | ||
| 기타 | intracapsular
|
scispacy | 1 | ||
| 기타 | posterior surface
|
scispacy | 1 |
MeSH Terms
Breast Implants; Female; Humans; Longitudinal Studies; Mammaplasty; Postoperative Complications; Prosthesis Failure; Silicone Gels; Ultrasonography
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.