In vitro investigation into the forces involved during lipofilling.
Abstract
Breast augmentation using implants is the most common aesthetic and reconstructive breast surgical procedure. Complications such as implant rupture maybe related to surgical technique and damage to the implant. Autologous fat transfer (lipofilling) using metallic cannulae has become a standard adjunctive, yet there is little evidence on lipofilling safety in the presence of implants. The aims of this study are to verify the effects of different cannulae and to quantify the forces applied by surgeons during lipofilling. Silicone gel-filled textured implants (200 mL), mounted on a specially constructed mould were ruptured with two different cannulae: type A (hole at tip: sharp) and type B (hole away from tip: blunt), driven at three speeds (10, 100 and 1000 mm/min), and the force at rupture was recorded. In addition, the maximum 10 forces over a 30-s period applied by 11 plastic surgeons against a breast implant in an in vitro environment were recorded using a load cell attached to a type-A cannula. Statistical analysis of comparative results was performed using t-tests, with p < 0.05 considered significant. Results showed that the implant ruptured at forces up to 25% lower when cannula A was used compared to cannula B. This supports current technique in lipofilling in the use of a blunt tipped cannula. There was a significant difference between some displacement rates only, due to the viscoelastic nature of the material. The tactile force that surgeons use during lipofilling was modelled in vitro and showed a range of maximum forces between 0.23 and 16.8 N, with a mean maximum value of 6.9 N. Limitation of this study is that it may not reflect in vivo behaviour of breast implants. More studies are needed to confirm the safety of breast lipofilling in the presence of implants using these data as a starting point.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 5 | |
| 해부 | tip
|
코끝 | dict | 2 | |
| 시술 | breast augmentation
|
유방성형술 | dict | 1 | |
| 해부 | fat
|
scispacy | 1 | ||
| 해부 | lipofilling
|
scispacy | 1 | ||
| 해부 | cell
|
scispacy | 1 | ||
| 합병증 | lipofilling
|
scispacy | 1 | ||
| 합병증 | blunt
|
scispacy | 1 | ||
| 합병증 | implant rupture
|
보형물 파열 | dict | 1 | |
| 질환 | rupture
|
C3203359
Rupture
|
scispacy | 1 | |
| 질환 | breast implant
|
C0178391
breast implant procedure
|
scispacy | 1 | |
| 질환 | type-A
|
scispacy | 1 | ||
| 질환 | breast lipofilling
|
scispacy | 1 | ||
| 기타 | cannulae
|
scispacy | 1 |
MeSH Terms
Breast Implants; Cannula; Lipectomy; Mechanical Phenomena; Safety
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.