[BACKGROUND] Motiva Implants (Establishment Labs Holdings Inc.) are a novel family of silicone breast implants using cutting-edge technologies engineered to optimize aesthetic and safety outcomes.

이 논문을 인용하기

BibTeX ↓ RIS ↓
APA Quirós MC, Bolaños MC, Fassero JJ (2019). Six-Year Prospective Outcomes of Primary Breast Augmentation With Nano Surface Implants.. Aesthetic surgery journal, 39(5), 495-508. https://doi.org/10.1093/asj/sjy196
MLA Quirós MC, et al.. "Six-Year Prospective Outcomes of Primary Breast Augmentation With Nano Surface Implants.." Aesthetic surgery journal, vol. 39, no. 5, 2019, pp. 495-508.
PMID 30423014
DOI 10.1093/asj/sjy196

Abstract

[BACKGROUND] Motiva Implants (Establishment Labs Holdings Inc.) are a novel family of silicone breast implants using cutting-edge technologies engineered to optimize aesthetic and safety outcomes.

[OBJECTIVES] The authors sought to prospectively evaluate the safety and effectiveness of SmoothSilk/SilkSurface Motiva Implants over long-term follow-up.

[METHODS] Surgeons at a single plastic surgery center undertook a 10-year follow-up study of SmoothSilk/SilkSurface Motiva Implants in women who underwent primary breast augmentation. Safety was assessed through identification of complications on follow-up and through magnetic resonance imaging (MRI) in a representative sample. Effectiveness outcomes were assessed by surgeons and patients using Likert scales and a Quality of Life tool.

[RESULTS] This article reports the 6-year safety and effectiveness outcomes. A total of 35 patients were implanted between September and December 2010, and 71.9% of implants were placed submuscularly using inframammary incision. During the 6-year follow-up, there were no occurrences of capsular contracture, rupture, double capsules, or late seroma. MRI evaluation identified no signs of implant-related complications. Three revision surgeries were performed, all for aesthetic reasons; there were no implant replacements for medical reasons. The level of satisfaction for both patients and surgeons was high at all follow-up visits. Patient quality-of-life scores increased following breast augmentation by an average of 0.89% at 72 months.

[CONCLUSIONS] The results of this prospective long-term follow-up study demonstrate the excellent safety and effectiveness of SmoothSilk/SilkSurface Motiva Implants in primary breast augmentation through 6 years of follow-up.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
해부 breast 유방 dict 5
시술 breast augmentation 유방성형술 dict 4
해부 inframammary scispacy 1
합병증 implant-related scispacy 1
합병증 seroma 장액종 dict 1
합병증 capsular contracture 피막구축 dict 1
약물 [BACKGROUND] Motiva Implants scispacy 1
약물 Labs scispacy 1
질환 silicone breast scispacy 1
질환 primary breast augmentation scispacy 1
질환 rupture C3203359
Rupture
scispacy 1
질환 implant-related complications scispacy 1
기타 women scispacy 1
기타 capsular scispacy 1

MeSH Terms

Adult; Breast Implantation; Breast Implants; Female; Follow-Up Studies; Humans; Magnetic Resonance Imaging; Middle Aged; Postoperative Complications; Prospective Studies; Prosthesis Design; Quality of Life; Silicone Gels

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문