Achieving Predictability in Augmentation Mastopexy: An Update.
Abstract
[BACKGROUND] One-stage augmentation mastopexy is a challenging procedure, with the highest cited revision rates in plastic surgery. This is because when mastopexy and augmentation are performed together, they lead to opposing forces, which must be balanced carefully to avoid complications. The goal of this study was to revisit a previously described predictable and safe approach to one-stage augmentation mastopexy, and provide long-term updated results.
[METHODS] One hundred seventy-one patients who underwent augmentation mastopexy, performed by a single surgeon (R.J.R.), were included in this retrospective review between January 2005 and January 2019. Wise pattern mastopexy with wide pedicle was performed before placement of a small subpectoral implant. Demographic information, preoperative breast measurements, intraoperative technique, implant choice, and postoperative complications were analyzed. Specifically, postoperative measurement of vertical limbs was performed to assess long-term elongation of the lower breast pole.
[RESULTS] Cumulative complication rate was 11.7%. This rate decreased to 6% in the last 88 patients in this series as the technique matured. The most common complication was revision for implant size exchange. Long-term follow-up demonstrated elongation of nipple-to-inframammary fold distance by 1.0-2.2 cm. There was no recurrence of ptosis requiring reoperation.
[CONCLUSIONS] This one-stage augmentation mastopexy technique provides a safe and reliable surgical approach with predictable and minimal elongation of the lower breast pole. The reoperation rate of this technique is less than half of >20% revision rate currently cited in the literature.
[METHODS] One hundred seventy-one patients who underwent augmentation mastopexy, performed by a single surgeon (R.J.R.), were included in this retrospective review between January 2005 and January 2019. Wise pattern mastopexy with wide pedicle was performed before placement of a small subpectoral implant. Demographic information, preoperative breast measurements, intraoperative technique, implant choice, and postoperative complications were analyzed. Specifically, postoperative measurement of vertical limbs was performed to assess long-term elongation of the lower breast pole.
[RESULTS] Cumulative complication rate was 11.7%. This rate decreased to 6% in the last 88 patients in this series as the technique matured. The most common complication was revision for implant size exchange. Long-term follow-up demonstrated elongation of nipple-to-inframammary fold distance by 1.0-2.2 cm. There was no recurrence of ptosis requiring reoperation.
[CONCLUSIONS] This one-stage augmentation mastopexy technique provides a safe and reliable surgical approach with predictable and minimal elongation of the lower breast pole. The reoperation rate of this technique is less than half of >20% revision rate currently cited in the literature.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | mastopexy
|
유방성형술 | dict | 7 | |
| 해부 | breast
|
유방 | dict | 3 | |
| 해부 | limbs
|
scispacy | 1 | ||
| 약물 | [BACKGROUND] One-stage
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS]
|
scispacy | 1 | ||
| 기법 | subpectoral
|
근막하 평면 | dict | 1 | |
| 질환 | ptosis
|
C0005745
Blepharoptosis
|
scispacy | 1 | |
| 기타 | patients
|
scispacy | 1 |
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.