Persistent Conjunctival Chemosis after Lower Lid Blepharoplasty: A Comparison of Different Surgical Techniques.

Journal of clinical medicine 2024 Vol.13(7)

Di Maria A, Barone G, Gaeta A, Confalonieri F, Vinciguerra P, Vinci V, Klinger M, Ferraro V

관련 도메인

Abstract

Conjunctival chemosis, a complication of lower blepharoplasty, can cause persistent discomfort and functional disturbances with worsening in the postoperative period following surgery. A review of the records of the lower blepharoplasty procedures carried out at the Humanitas Research Hospital, Rozzano, Milan, Italy was performed. Patients were categorized into two groups depending on the procedure performed: (1) transconjunctival blepharoplasty with the removal of the fatty lodges with canthopexy and (2) transcutaneous blepharoplasty with the removal of the fatty lodges with lateral canthoplasty. Each group was further divided into two more groups based on the surgical method used, that is either (a) cold blade and disposable cautery or (b) radiofrequency cut and coagulation and colorado tip (respectively 1a, 1b, 2a and 2b). All patients underwent a postoperative follow-up up to 24 months, which included an evaluation of cosmetic appearance, eyelid scarring and the severity of chemosis. The aim of the study was to investigate which of the surgical procedures causes a lower incidence of persistent type 3 conjunctival chemosis. A total of 1047 patients who underwent lower lid blepharoplasty were included in the study. A total of 512 patients underwent transcutaneous blepharoplasty and 535 underwent the transconjunctival procedure. Among the first group of patients, 266 belong to group 1a and 246 to group 1b. In the second group, 264 were categorized as group 2a and 271 as group 2b. The incidence of type 3 chemosis in the transcutaneous blepharoplasty procedure with lateral canthoplasty was statistically significantly higher than in the transconjunctival approach, considering both the cold blade and the radiofrequency ( = 0.012, 0.010, 0.006, 0.004, respectively). A higher incidence of persistent type 3 conjunctival chemosis is associated with lateral canthus surgery and with the use of radiofrequency.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
시술 blepharoplasty 안검성형술 dict 6
시술 lower blepharoplasty 안검성형술 dict 2
기법 transconjunctival 경결막 접근 dict 2
해부 colorado scispacy 1
해부 tip 코끝 dict 1
해부 eyelid 눈꺼풀 dict 1
기법 transconjunctival approach 경결막 접근 dict 1
질환 Chemosis C0271298
Chemosis of conjunctiva
scispacy 1
질환 Conjunctival chemosis C0271298
Chemosis of conjunctiva
scispacy 1
기타 Patients scispacy 1
기타 canthopexy scispacy 1
기타 lateral canthoplasty scispacy 1
기타 lateral canthus scispacy 1

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문