Assessment of Arterial Involvement in Pancreatic Cancer: Utility of Reconstructed CT Images Perpendicular to Artery.
The purpose of this study was to investigate the utility of reconstructed CT images perpendicular to the artery for assessing arterial involvement from pancreatic cancer and compare the interobserver
APA
Noda Y, Kobayashi K, et al. (2024). Assessment of Arterial Involvement in Pancreatic Cancer: Utility of Reconstructed CT Images Perpendicular to Artery.. Cancers, 16(12). https://doi.org/10.3390/cancers16122271
MLA
Noda Y, et al.. "Assessment of Arterial Involvement in Pancreatic Cancer: Utility of Reconstructed CT Images Perpendicular to Artery.." Cancers, vol. 16, no. 12, 2024.
PMID
38927975
Abstract
The purpose of this study was to investigate the utility of reconstructed CT images perpendicular to the artery for assessing arterial involvement from pancreatic cancer and compare the interobserver variability between it and the current diagnostic imaging method. This retrospective study included patients with pancreatic cancer in the pancreatic body or tail who underwent preoperative pancreatic protocol CT and distal pancreatectomy. Five radiologists used axial and coronal CT images (current method) and perpendicular reconstructed CT images (proposed method) to determine if the degree of solid soft-tissue contact with the splenic artery was ≤180° or >180°. The generalized estimating equations were used to compare the diagnostic performance of solid soft-tissue contact >180° between the current and proposed methods. Fleiss' statistics were used to assess interobserver variability. The sensitivity and negative predictive value for diagnosing solid soft-tissue contact >180° were higher ( < 0.001 for each) and the specificity ( = 0.003) and positive predictive value ( = 0.003) were lower in the proposed method than the current method. Interobserver variability was improved in the proposed method compared with the current method ( = 0.87 vs. 0.67). Reconstructed CT images perpendicular to the artery showed higher sensitivity and negative predictive value for diagnosing solid soft-tissue contact >180° than the current method and demonstrated improved interobserver variability.
같은 제1저자의 인용 많은 논문 (2)
- Novel silicon-based material decomposition images in diagnosis of pancreatic ductal adenocarcinoma: comparison with iodine-based and 50-keV virtual monoenergetic images.
- Optimized versus conventional trigger threshold for pancreatic phase image acquisition using dual-energy CT at 40-keV: a randomized controlled trial.