본문으로 건너뛰기
← 뒤로

Determination of the pyrrolo[2,3-d] pyrimidine antifolate AGF94 from a preclinical murine study using a simple UHPLC-MS/MS assay.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences 2025 Vol.1267() p. 124833

Metz TT, Ashe RC, Duncan AC, Wilner EC, Schmidt KT, Gudmundsson KO, Hou Z, Gangjee A, Matherly LH, Kozlov SV, Figg WD

📝 환자 설명용 한 줄

A UHPLC-MS/MS method for the detection and quantification of the 6-substituted pyrrolo[2,3-d] pyrimidine AGF94, a novel antifolate, in mouse plasma and tissue was developed and validated.

이 논문을 인용하기

BibTeX ↓ RIS ↓
APA Metz TT, Ashe RC, et al. (2025). Determination of the pyrrolo[2,3-d] pyrimidine antifolate AGF94 from a preclinical murine study using a simple UHPLC-MS/MS assay.. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 1267, 124833. https://doi.org/10.1016/j.jchromb.2025.124833
MLA Metz TT, et al.. "Determination of the pyrrolo[2,3-d] pyrimidine antifolate AGF94 from a preclinical murine study using a simple UHPLC-MS/MS assay.." Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, vol. 1267, 2025, pp. 124833.
PMID 41878958

Abstract

A UHPLC-MS/MS method for the detection and quantification of the 6-substituted pyrrolo[2,3-d] pyrimidine AGF94, a novel antifolate, in mouse plasma and tissue was developed and validated. The developed method relies on a simple protein precipitation with methanol, followed by separation on a C18 column using a gradient solvent system of acetonitrile and water with 0.1 % formic acid in both. Detection and quantification of AGF94 were achieved by multiple reaction monitoring using a Sciex QTRAP 5500 mass spectrometer operated in positive electrospray ionization mode. The transitions for AGF94 and the internal standard were m/z 448 to 137 and 442 to 295, respectively. The calibration curve ranged from 5 to 500 ng/mL in mouse plasma with a linearity of R = 0.99611 ± 0.00280 across multiple days. Accuracy of the assay ranged from -6.22 to 5.56 % and precision was less than 11.58 % off from nominal concentrations. Benchtop, freeze/thaw cycling, and autosampler stabilities did not indicate any substantial changes in concentrations during processing. The overall process efficiency was greater than 96 % for both the analyte and internal standard. The precision and accuracy of the assay were established, and the assay was utilized to analyze preclinical samples from a pharmacokinetic study using AGF94 in a murine pancreatic cancer model. Pharmacokinetic parameters from a noncompartmental analysis of AGF94 in multiple matrices were reported utilizing the validated method.

MeSH Terms

Animals; Tandem Mass Spectrometry; Mice; Chromatography, High Pressure Liquid; Pyrimidines; Reproducibility of Results; Pyrroles; Linear Models; Folic Acid Antagonists; Limit of Detection; Male