본문으로 건너뛰기
← 뒤로

Evaluation of voice function after BABA robotic thyroid lobectomy: A comparative analysis with endoscopic thyroid lobectomy.

1/5 보강
Medicine 📖 저널 OA 98.4% 2021: 23/23 OA 2022: 25/25 OA 2023: 59/59 OA 2024: 58/58 OA 2025: 274/285 OA 2026: 186/186 OA 2021~2026 2022 Vol.101(50) p. e32321
Retraction 확인
출처

PICO 자동 추출 (휴리스틱, conf 2/4)

유사 논문
P · Population 대상 환자/모집단
125 patients with thyroid cancer from March 2021 to July 2022 were divided into the robotic thyroid lobectomy group and the endoscopic thyroid lobectomy group.
I · Intervention 중재 / 시술
추출되지 않음
C · Comparison 대조 / 비교
추출되지 않음
O · Outcome 결과 / 결론
There were no significant differences in Shimmer, Jitter, DSI and NHR during all postoperative follow-up periods compared with those before surgery in both groups. The voice function of robotic thyroid lobectomy via BABA is superior to endoscopic thyroid lobectomy.

Liu P, Yan J, Yang H, Yang Y

📖 무료 전문 🟢 PMC 전문 PMC9771197
📝 환자 설명용 한 줄

The purpose of this study was to compare the effect of robotic thyroid lobectomy via Bilateral Axlio-Breast Approach (BABA) and endoscopic thyroid lobectomy on the voice function.

이 논문을 인용하기

↓ .bib ↓ .ris
APA Liu P, Yan J, et al. (2022). Evaluation of voice function after BABA robotic thyroid lobectomy: A comparative analysis with endoscopic thyroid lobectomy.. Medicine, 101(50), e32321. https://doi.org/10.1097/MD.0000000000032321
MLA Liu P, et al.. "Evaluation of voice function after BABA robotic thyroid lobectomy: A comparative analysis with endoscopic thyroid lobectomy.." Medicine, vol. 101, no. 50, 2022, pp. e32321.
PMID 36550846 ↗

Abstract

The purpose of this study was to compare the effect of robotic thyroid lobectomy via Bilateral Axlio-Breast Approach (BABA) and endoscopic thyroid lobectomy on the voice function. A total of 125 patients with thyroid cancer from March 2021 to July 2022 were divided into the robotic thyroid lobectomy group and the endoscopic thyroid lobectomy group. Acoustic index and voice handicap index (VHI-10) were compared between the 2 groups before and after (1 week, 1 month, 3 month) the surgery. In the robotic group, VHI-10 score was not significantly different before and after the surgery. In the endoscopic group, VHI-10 score after the surgery was significantly higher than that before the surgery. In the endoscopic group, the fundamental frequency (F0) declined significantly 1 week and 1 month after the surgery compared with that before the surgery. One week after surgery, F0 in the endoscopic group was (197.91 ± 24.15) Hz, which was significantly lower than that (206.77 ± 20.13) Hz in the robotic group. In the robotic group, there was no obvious decline in F0 and MPT in each follow-up period after surgery compared with those before surgery. In the endoscopic group, MPT declined significantly 1 week after the surgery compared with that before surgery. One week after surgery, MPT in the endoscopic group was (13.02 ± 9.28) s, which was significantly lower than that (17.55 ± 9.25) s in the robotic groups. There were no significant differences in Shimmer, Jitter, DSI and NHR during all postoperative follow-up periods compared with those before surgery in both groups. The voice function of robotic thyroid lobectomy via BABA is superior to endoscopic thyroid lobectomy.

🏷️ 키워드 / MeSH 📖 같은 키워드 OA만

같은 제1저자의 인용 많은 논문 (5)

🏷️ 같은 키워드 · 무료전문 — 이 논문 MeSH/keyword 기반

🟢 PMC 전문 열기