A prospective comparison of ACR-TIRADS and EU-TIRADS in thyroid nodule assessment for FNA-US.
1/5 보강
PICO 자동 추출 (휴리스틱, conf 3/4)
유사 논문P · Population 대상 환자/모집단
166 patients were evaluated, resulting in 168 nodules from 149 patients with conclusive benign or malignant results.
I · Intervention 중재 / 시술
fine-needle aspiration (FNA) under ultrasonographic guidance (FNA-US) were prospectively evaluated
C · Comparison 대조 / 비교
추출되지 않음
O · Outcome 결과 / 결론
Sensitivity, specificity, negative predictive value (NPV) and false negative (FN) were 100.0%, 28.7%, 100.0% and 0.0%, respectively, for ACR-TIRADS; and 90.0%, 19.1%, 96.8% and 9.1% (n = 1), respectively, for EU-TIRADS.
[OBJECTIVE] Prospective data on the accuracy of ultrasound (US) classification systems in thyroid nodules are still scarce.
- 표본수 (n) 1
- p-value p = .017
- Specificity 30.6%
APA
Eidt LB, Nunes de Oliveira C, et al. (2023). A prospective comparison of ACR-TIRADS and EU-TIRADS in thyroid nodule assessment for FNA-US.. Clinical endocrinology, 98(3), 415-425. https://doi.org/10.1111/cen.14799
MLA
Eidt LB, et al.. "A prospective comparison of ACR-TIRADS and EU-TIRADS in thyroid nodule assessment for FNA-US.." Clinical endocrinology, vol. 98, no. 3, 2023, pp. 415-425.
PMID
35864563 ↗
Abstract 한글 요약
[OBJECTIVE] Prospective data on the accuracy of ultrasound (US) classification systems in thyroid nodules are still scarce. The aim of this study is to compare the accuracy of the American College of Radiology Thyroid Imaging Reporting and Data System (ACR-TIRADS) and European (EU)-TIRADS classification systems.
[DESIGN AND PATIENTS] Consecutive patients with one or more thyroid nodule(s) who underwent fine-needle aspiration (FNA) under ultrasonographic guidance (FNA-US) were prospectively evaluated.
[MEASUREMENTS] Clinical evaluation and US data were collected. The reference standard used for this study was FNA-US cytology and histopathological diagnosis.
[RESULTS] A total of 186 thyroid nodules in 166 patients were evaluated, resulting in 168 nodules from 149 patients with conclusive benign or malignant results. Sensitivity, specificity, negative predictive value (NPV) and false negative (FN) were 100.0%, 28.7%, 100.0% and 0.0%, respectively, for ACR-TIRADS; and 90.0%, 19.1%, 96.8% and 9.1% (n = 1), respectively, for EU-TIRADS. The number of unnecessary FNA-US indicated by ACR-TIRADS was lower than EU-TIRADS (71.3% vs. 80.9%, p = .017), and the number of possibly avoided FNA-US was higher (26.7% vs. 17.8%). Using the same threshold of ACR-TIRADS to indicate FNA-US in EU-TIRADS 3 nodules (2.5 cm), there was an improvement in specificity (30.6%) and avoided FNA-US (28.6%). The best performance of both systems was demonstrated when FNA-US would be indicated only in highly suspicious nodules and/or in the presence of lymphadenopathy, with 85.7% and 89.3% of possibly avoided FNA-US for ACR-TIRADS and EU-TIRADS, respectively, without increasing FN.
[CONCLUSION] Both systems presented high sensitivity, but low specificity in selecting nodules for FNA-US. The use of nodular size for FNA-US selection is questioned.
[DESIGN AND PATIENTS] Consecutive patients with one or more thyroid nodule(s) who underwent fine-needle aspiration (FNA) under ultrasonographic guidance (FNA-US) were prospectively evaluated.
[MEASUREMENTS] Clinical evaluation and US data were collected. The reference standard used for this study was FNA-US cytology and histopathological diagnosis.
[RESULTS] A total of 186 thyroid nodules in 166 patients were evaluated, resulting in 168 nodules from 149 patients with conclusive benign or malignant results. Sensitivity, specificity, negative predictive value (NPV) and false negative (FN) were 100.0%, 28.7%, 100.0% and 0.0%, respectively, for ACR-TIRADS; and 90.0%, 19.1%, 96.8% and 9.1% (n = 1), respectively, for EU-TIRADS. The number of unnecessary FNA-US indicated by ACR-TIRADS was lower than EU-TIRADS (71.3% vs. 80.9%, p = .017), and the number of possibly avoided FNA-US was higher (26.7% vs. 17.8%). Using the same threshold of ACR-TIRADS to indicate FNA-US in EU-TIRADS 3 nodules (2.5 cm), there was an improvement in specificity (30.6%) and avoided FNA-US (28.6%). The best performance of both systems was demonstrated when FNA-US would be indicated only in highly suspicious nodules and/or in the presence of lymphadenopathy, with 85.7% and 89.3% of possibly avoided FNA-US for ACR-TIRADS and EU-TIRADS, respectively, without increasing FN.
[CONCLUSION] Both systems presented high sensitivity, but low specificity in selecting nodules for FNA-US. The use of nodular size for FNA-US selection is questioned.
🏷️ 키워드 / MeSH 📖 같은 키워드 OA만
🏷️ 같은 키워드 · 무료전문 — 이 논문 MeSH/keyword 기반
- A Phase I Study of Hydroxychloroquine and Suba-Itraconazole in Men with Biochemical Relapse of Prostate Cancer (HITMAN-PC): Dose Escalation Results.
- Self-management of male urinary symptoms: qualitative findings from a primary care trial.
- Clinical and Liquid Biomarkers of 20-Year Prostate Cancer Risk in Men Aged 45 to 70 Years.
- Diagnostic accuracy of Ga-PSMA PET/CT versus multiparametric MRI for preoperative pelvic invasion in the patients with prostate cancer.
- Comprehensive analysis of androgen receptor splice variant target gene expression in prostate cancer.
- Clinical Presentation and Outcomes of Patients Undergoing Surgery for Thyroid Cancer.