Real-Time Ultrasonography and the Evaluation of Static Images Yield Different Results in the Assessment of EU-TIRADS Categories.

1/5 보강
Journal of clinical medicine 📖 저널 OA 100% 2021: 34/34 OA 2022: 61/61 OA 2023: 78/78 OA 2024: 135/135 OA 2025: 265/265 OA 2026: 192/192 OA 2021~2026 2023 Vol.12(18)
Retraction 확인
출처

Słowińska-Klencka D, Popowicz B, Klencki M

📝 환자 설명용 한 줄

The studies on the effectiveness of various TIRADS in the diagnostics of thyroid nodules differ in the method of ultrasound image assessment: real time (rtUS) vs.

이 논문을 인용하기

↓ .bib ↓ .ris
APA Słowińska-Klencka D, Popowicz B, Klencki M (2023). Real-Time Ultrasonography and the Evaluation of Static Images Yield Different Results in the Assessment of EU-TIRADS Categories.. Journal of clinical medicine, 12(18). https://doi.org/10.3390/jcm12185809
MLA Słowińska-Klencka D, et al.. "Real-Time Ultrasonography and the Evaluation of Static Images Yield Different Results in the Assessment of EU-TIRADS Categories.." Journal of clinical medicine, vol. 12, no. 18, 2023.
PMID 37762750 ↗
DOI 10.3390/jcm12185809

Abstract

The studies on the effectiveness of various TIRADS in the diagnostics of thyroid nodules differ in the method of ultrasound image assessment: real time (rtUS) vs. static ultrasonography (stUS). The aim of the study was to evaluate the impact of those two methods on the categorization of nodules in EU-TIRADS. Three experienced raters assessed 842 nodules in routine rtUS and reassessed with the use of sUS. Reproducibility of the assessment of malignancy risk features and categorization of nodules with EU-TIRADS was estimated with Krippendorff's alpha coefficient (Kα). The reproducibility of EU-TIRADS categories on sUS in relation to rtUS was in range 70.9-76.5% for all raters (Kα: 0.60-0.68) with the highest reproducibility for category 3 (80.0-86.5%) and the lowest for category 5 (48.7-77.8%). There was a total disagreement of the identification of microcalcifications on sUS in relation to rtUS, a strongly variable reproducibility of marked hypoechogenicity (12.5-84.6%, Kα: 0.14-0.48) and a tendency toward more frequent identification of the non-oval shape on sUS. The percentage of agreement for each pair of raters in assigning the EU-TIRADS category on sUS was in the range 71.6-72.3% (Kα: 0.60-0.62). The method of sonographic image evaluation influences the nodule's feature assessment and, eventually, the categorization within EU-TIRADS.