Cone-beam computed tomography (CBCT) image-quality improvement using a denoising diffusion probabilistic model conditioned by pseudo-CBCT of pelvic regions.

1/5 보강
Radiological physics and technology 2025 Vol.18(2) p. 425-438
Retraction 확인
출처

PICO 자동 추출 (휴리스틱, conf 3/4)

유사 논문
P · Population 대상 환자/모집단
This reduces the accuracy of Hounsfield units (HU) and limits its use in adaptive radiation therapy (ART).
I · Intervention 중재 / 시술
them in terms of accuracy and anatomical preservation
C · Comparison 대조 / 비교
추출되지 않음
O · Outcome 결과 / 결론
Gamma pass rates for the proposed sCT exceeded 90% for all dose criteria, indicating high agreement with CT-based dose distributions. These results show that the proposed sCT improves image quality, dosimetry accuracy, and treatment planning, advancing ART for pelvic cancer.

Hattori M, Chai H, Hiraka T, Suzuki K, Yuasa T

📝 환자 설명용 한 줄

Cone-beam computed tomography (CBCT) is widely used in radiotherapy to image patient configuration before treatment but its image quality is lower than planning CT due to scattering, motion, and recon

이 논문을 인용하기

↓ .bib ↓ .ris
APA Hattori M, Chai H, et al. (2025). Cone-beam computed tomography (CBCT) image-quality improvement using a denoising diffusion probabilistic model conditioned by pseudo-CBCT of pelvic regions.. Radiological physics and technology, 18(2), 425-438. https://doi.org/10.1007/s12194-025-00892-4
MLA Hattori M, et al.. "Cone-beam computed tomography (CBCT) image-quality improvement using a denoising diffusion probabilistic model conditioned by pseudo-CBCT of pelvic regions.." Radiological physics and technology, vol. 18, no. 2, 2025, pp. 425-438.
PMID 40035984 ↗

Abstract

Cone-beam computed tomography (CBCT) is widely used in radiotherapy to image patient configuration before treatment but its image quality is lower than planning CT due to scattering, motion, and reconstruction methods. This reduces the accuracy of Hounsfield units (HU) and limits its use in adaptive radiation therapy (ART). However, synthetic CT (sCT) generation using deep learning methods for CBCT intensity correction faces challenges due to deformation. To address these issues, we propose enhancing CBCT quality using a conditional denoising diffusion probability model (CDDPM), which is trained on pseudo-CBCT created by adding pseudo-scatter to planning CT. The CDDPM transforms CBCT into high-quality sCT, improving HU accuracy while preserving anatomical configuration. The performance evaluation of the proposed sCT showed a reduction in mean absolute error (MAE) from 81.19 HU for CBCT to 24.89 HU for the sCT. Peak signal-to-noise ratio (PSNR) improved from 31.20 dB for CBCT to 33.81 dB for the sCT. The Dice and Jaccard coefficients between CBCT and sCT for the colon, prostate, and bladder ranged from 0.69 to 0.91. When compared to other deep learning models, the proposed sCT outperformed them in terms of accuracy and anatomical preservation. The dosimetry analysis for prostate cancer revealed a dose error of over 10% with CBCT but nearly 0% with the sCT. Gamma pass rates for the proposed sCT exceeded 90% for all dose criteria, indicating high agreement with CT-based dose distributions. These results show that the proposed sCT improves image quality, dosimetry accuracy, and treatment planning, advancing ART for pelvic cancer.