본문으로 건너뛰기
← 뒤로

A fully automated AI-based method for tumour detection and quantification on [F]PSMA-1007 PET-CT images in prostate cancer.

1/5 보강
EJNMMI physics 📖 저널 OA 100% 2024: 1/1 OA 2025: 14/14 OA 2026: 6/6 OA 2024~2026 2025 Vol.12(1) p. 78
Retraction 확인
출처

Trägårdh E, Ulén J, Enqvist O, Larsson M, Valind K, Minarik D, Edenbrandt L

📝 환자 설명용 한 줄

[BACKGROUND] In this study, we further developed an artificial intelligence (AI)-based method for the detection and quantification of tumours in the prostate, lymph nodes and bone in prostate-specific

이 논문을 인용하기

↓ .bib ↓ .ris
APA Trägårdh E, Ulén J, et al. (2025). A fully automated AI-based method for tumour detection and quantification on [F]PSMA-1007 PET-CT images in prostate cancer.. EJNMMI physics, 12(1), 78. https://doi.org/10.1186/s40658-025-00786-9
MLA Trägårdh E, et al.. "A fully automated AI-based method for tumour detection and quantification on [F]PSMA-1007 PET-CT images in prostate cancer.." EJNMMI physics, vol. 12, no. 1, 2025, pp. 78.
PMID 40833689 ↗

Abstract

[BACKGROUND] In this study, we further developed an artificial intelligence (AI)-based method for the detection and quantification of tumours in the prostate, lymph nodes and bone in prostate-specific membrane antigen (PSMA)-targeting positron emission tomography with computed tomography (PET-CT) images.

[METHODS] A total of 1064 [F]PSMA-1007 PET-CT scans were used (approximately twice as many compared to our previous AI model), of which 120 were used as test set. Suspected lesions were manually annotated and used as ground truth. A convolutional neural network was developed and trained. The sensitivity and positive predictive value (PPV) were calculated using two sets of manual segmentations as reference. Results were also compared to our previously developed AI method. The correlation between manually and AI-based calculations of total lesion volume (TLV) and total lesion uptake (TLU) were calculated.

[RESULTS] The sensitivities of the AI method were 85% for prostate tumour/recurrence, 91% for lymph node metastases and 61% for bone metastases (82%, 86% and 70% for manual readings and 66%, 88% and 71% for the old AI method). The PPVs of the AI method were 85%, 83% and 58%, respectively (63%, 86% and 39% for manual readings, and 69%, 70% and 39% for the old AI method). The correlations between manual and AI-based calculations of TLV and TLU ranged from r = 0.62 to r = 0.96.

[CONCLUSION] The performance of the newly developed and fully automated AI-based method for detecting and quantifying prostate tumour and suspected lymph node and bone metastases increased significantly, especially the PPV. The AI method is freely available to other researchers ( www.recomia.org ).

🏷️ 키워드 / MeSH 📖 같은 키워드 OA만

같은 제1저자의 인용 많은 논문 (1)

🏷️ 같은 키워드 · 무료전문 — 이 논문 MeSH/keyword 기반

🟢 PMC 전문 열기