Design an open-access dynamic spot-scanning proton arc system controller for quantitative and comprehensive investigation of delivery efficiency.

1/5 보강
Medical physics 2026 Vol.53(1) p. e70213
Retraction 확인
출처

Cong X, Liu G, Liu P, Zhao L, Chen S, Deroniyagala R, Stevens C, Xu X, Li X, Ding X

📝 환자 설명용 한 줄

[BACKGROUND] Proton arc therapy enables continuous treatment delivery while rotating the gantry.

이 논문을 인용하기

BibTeX ↓ RIS ↓
APA Cong X, Liu G, et al. (2026). Design an open-access dynamic spot-scanning proton arc system controller for quantitative and comprehensive investigation of delivery efficiency.. Medical physics, 53(1), e70213. https://doi.org/10.1002/mp.70213
MLA Cong X, et al.. "Design an open-access dynamic spot-scanning proton arc system controller for quantitative and comprehensive investigation of delivery efficiency.." Medical physics, vol. 53, no. 1, 2026, pp. e70213.
PMID 41455058
DOI 10.1002/mp.70213

Abstract

[BACKGROUND] Proton arc therapy enables continuous treatment delivery while rotating the gantry. One of the key components in the proton arc system is the controller's design, which determines the irradiation sequence and gantry mechanical rotation.

[PURPOSE] This study aims to develop a novel and open-access proton arc system controller (controller) and comprehensively investigates the treatment delivery time in a relationship of different mechanical parameters.

[METHOD] The controller applied control theory to iteratively optimize and calculate the irradiation sequence across the control points to ensure an efficient treatment delivery while meeting the mechanical constraints. The calculation considers the parameters such as tolerance window, buffer window, and maximum acceleration and deceleration speed of the gantry. Five different disease sites, e.g., liver, head, and neck, intracranial, lung, and prostate cancer cases were used for testing purposes. Various parameters and settings were used to quantitatively investigate the dynamic spot-scanning proton arc (SPArc) treatment delivery time and total momentum changes.

[RESULT] The result indicates that the significant impact of dynamic treatment delivery time comes from the buffer window setting relative to the tolerance window, in which a large buffer leads to a slower delivery process. On the other hand, the maximum acceleration and deceleration speed plays an important role in the treatment delivery efficiency if the buffer window occupies large portion of each tolerance window. Additionally, the buffer window setting also impacts the total momentum changes during the dynamic treatment delivery.

[CONCLUSION] The study introduced the first open-access controller for dynamic treatment delivery simulation, allowing clinical users or investigators to adjust various machine parameters for testing purposes. This platform could serve as a foundation for testing future advancements in the dynamic SPArc technology, including hardware, system controller, and treatment planning optimization algorithm design.