본문으로 건너뛰기
← 뒤로

Ultrasensitive detection of gastric cancer biomarker using tetrahedral DNA nanostructure-functionalized floating-gate carbon nanotube field-effect transistor biosensor.

3/5 보강
Biosensors & bioelectronics 2026 Vol.300() p. 118475 cited 1 Advanced biosensing and bioanalysis
TL;DR These findings validate the potential of TDN-functionalized FG CNTFET architecture for aM-level early GC screening, laying a technological foundation for the development of low-cost, portable point-of-care testing (POCT) devices.
Retraction 확인
출처
PubMed DOI OpenAlex Semantic 마지막 보강 2026-04-28
OpenAlex 토픽 · Advanced biosensing and bioanalysis techniques Carbon Nanotubes in Composites Nanopore and Nanochannel Transport Studies

Liu J, Gu Y, Li F, Ma S, Li X, Wang X, Lv T, Hu J, Han C

📝 환자 설명용 한 줄

These findings validate the potential of TDN-functionalized FG CNTFET architecture for aM-level early GC screening, laying a technological foundation for the development of low-cost, portable point-of

이 논문을 인용하기

↓ .bib ↓ .ris
APA Jiale Liu, Yuqing Gu, et al. (2026). Ultrasensitive detection of gastric cancer biomarker using tetrahedral DNA nanostructure-functionalized floating-gate carbon nanotube field-effect transistor biosensor.. Biosensors & bioelectronics, 300, 118475. https://doi.org/10.1016/j.bios.2026.118475
MLA Jiale Liu, et al.. "Ultrasensitive detection of gastric cancer biomarker using tetrahedral DNA nanostructure-functionalized floating-gate carbon nanotube field-effect transistor biosensor.." Biosensors & bioelectronics, vol. 300, 2026, pp. 118475.
PMID 41643422

Abstract

Early screening is crucial for improving the survival rate of gastric cancer (GC). MiRNA-106a is abnormally overexpressed in GC tissues, making it an ideal biomarker for liquid biopsy. In this study, a floating-gate carbon nanotube field-effect transistor (FG CNTFET) biosensor, functionalized with tetrahedral DNA nanostructure (TDN) probes was developed to enable label-free, highly sensitive detection of miRNA 106a. The FG layer not only physically isolates the CNT channel from the complex biological environment-shielding it against moisture, ions, and impurities-but also amplifies surface potential changes via capacitive coupling, thereby enhancing both device stability and sensitivity. The rigid framework of TDN probes overcomes the issues of aggregation and entanglement issues associated with single-stranded DNA (ssDNA), reducing steric hindrance and improving target accessibility. In static mode, the biosensor exhibited a linear detection range of 1 fM-1 μM with a detection limit (LOD) as low as 7 aM. Under dynamic conditions, it enabled real-time tracking of miRNA-106a binding events with an LOD of 1 pM. Preliminary analysis of 12 pilot clinical serum samples demonstrated the biosensor's capability of distinguishing patients from healthy donors, despite the limited sample size. These findings validate the potential of TDN-functionalized FG CNTFET architecture for aM-level early GC screening, laying a technological foundation for the development of low-cost, portable point-of-care testing (POCT) devices.

MeSH Terms

Biosensing Techniques; Humans; Nanotubes, Carbon; Stomach Neoplasms; MicroRNAs; Biomarkers, Tumor; Limit of Detection; Transistors, Electronic; Nanostructures; DNA; Equipment Design; Early Detection of Cancer

같은 제1저자의 인용 많은 논문 (5)