본문으로 건너뛰기
← 뒤로

First Experience of Tricuspid Transcatheter-Edge-to-Edge Repair Using 3D Mini-Transesophageal Echocardiography and Intracardiac Echocardiography.

1/5 보강
JACC. Case reports 📖 저널 OA 98.1% 2025 Vol.30(33) p. 105598
Retraction 확인
출처

PICO 자동 추출 (휴리스틱, conf 2/4)

유사 논문
P · Population 대상 환자/모집단
환자: large esophageal varices and advanced liver disease
I · Intervention 중재 / 시술
추출되지 않음
C · Comparison 대조 / 비교
추출되지 않음
O · Outcome 결과 / 결론
[TAKE-HOME MESSAGE] Miniature TEE enables safe imaging in high-risk esophageal anatomy. Individualized imaging strategies can expand access to structural interventions in complex patients.

Ibrahim M, O'Sullivan S, El Sabbagh A, Reddy P

📝 환자 설명용 한 줄

[OBJECTIVES] To describe the first experience of using a 9-mm miniature transesophageal echocardiography (TEE) probe combined with intracardiac echocardiography (ICE) to safely guide tricuspid transca

이 논문을 인용하기

↓ .bib ↓ .ris
APA Ibrahim M, O'Sullivan S, et al. (2025). First Experience of Tricuspid Transcatheter-Edge-to-Edge Repair Using 3D Mini-Transesophageal Echocardiography and Intracardiac Echocardiography.. JACC. Case reports, 30(33), 105598. https://doi.org/10.1016/j.jaccas.2025.105598
MLA Ibrahim M, et al.. "First Experience of Tricuspid Transcatheter-Edge-to-Edge Repair Using 3D Mini-Transesophageal Echocardiography and Intracardiac Echocardiography.." JACC. Case reports, vol. 30, no. 33, 2025, pp. 105598.
PMID 41136052

Abstract

[OBJECTIVES] To describe the first experience of using a 9-mm miniature transesophageal echocardiography (TEE) probe combined with intracardiac echocardiography (ICE) to safely guide tricuspid transcatheter edge-to-edge repair (TEER) in a patient with large esophageal varices and advanced liver disease.

[KEY STEPS] Multidisciplinary evaluation identified severe tricuspid regurgitation in a patient with cirrhosis and suspected hepatocellular carcinoma. Hemodynamic and anatomic assessment was conducted with transthoracic echocardiography, TEE, coronary computed tomography angiogram, and right heart catheterization. A 9-mm miniature TEE probe was selected to minimize esophageal trauma, and 2 TriClip XTW devices were successfully implanted with combined TEE and intracardiac echocardiography guidance. Postprocedural optimization enabled safe progression to Y-90 radioembolization.

[POTENTIAL PITFALLS] Miniature TEE probes have limited resolution, reduced three-dimensional imaging, and shorter shaft length, requiring operator experience and adjunct imaging to ensure procedural success.

[TAKE-HOME MESSAGE] Miniature TEE enables safe imaging in high-risk esophageal anatomy. Individualized imaging strategies can expand access to structural interventions in complex patients.

🏷️ 키워드 / MeSH

같은 제1저자의 인용 많은 논문 (1)

🟢 PMC 전문 열기