Is there a need for a CT scan of the pancreatic phase? A perfusion and simulation study of the pancreas, an HCC, and the kidney cortex.
1/5 보강
ℹ️ 이 논문은 무료 전문이 아직 없습니다. 코퍼스 전체의 44.0%는 무료 가능 (통계 →) · 🏥 기관 EZproxy로 시도
To explore the peak enhancement time of a hepatocellular carcinoma, the pancreas, and the kidney cortex and its determinants.We obtained a time enhancement curve from the perfusion CT scans of 11 adva
- p-value p=0.082
- p-value p=0.069
APA
Cressoni M, Cadringher P, et al. (2025). Is there a need for a CT scan of the pancreatic phase? A perfusion and simulation study of the pancreas, an HCC, and the kidney cortex.. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 197(12), 1405-1415. https://doi.org/10.1055/a-2516-3176
MLA
Cressoni M, et al.. "Is there a need for a CT scan of the pancreatic phase? A perfusion and simulation study of the pancreas, an HCC, and the kidney cortex.." RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, vol. 197, no. 12, 2025, pp. 1405-1415.
PMID
39914465 ↗
Abstract 한글 요약
To explore the peak enhancement time of a hepatocellular carcinoma, the pancreas, and the kidney cortex and its determinants.We obtained a time enhancement curve from the perfusion CT scans of 11 advanced HCC patients (40 volumes at 1.25 s time interval, slab slice 90 mm, bolus of 50 ml of iodinated contrast agent, 350 g iodine/ml, flow 5 ml/s). Small regions of interest were drawn on the abdominal aorta, the HCC, the cortex of the right kidney, and on the pancreas. The behavior of the contrast agent in the capillary and in the surrounding tissue was further explored with a finite element model.The peak enhancement time of the pancreas did not differ from that of the HCC (10±3 vs. 11±4 s, p=0.9), while the peak enhancement time of the kidney tended to be a few seconds earlier (8±1 s, p=0.082 vs. pancreas and p=0.069 vs. kidney). Simulation showed that the time span in which the tissue enhancement remained within 10% of its peak value was similar across all capillary densities and ranged between 26-38 s for a capillary density of 80 per mm to 30-60 s for a capillary density of 10.The plateau tissue enhancement clinically acquired in the "late arterial phase" should be adequate both for the detection of hypervascular liver lesions such as HCCs and for obtaining peak pancreatic enhancement to detect hypovascular lesions. · The peak tissue enhancement time of an HCC, the pancreas, and the kidney cortex is similar. · The tissue peak enhancement time in the arterial phase is at the end of bolus transit. · Simulation shows that tissue enhancement peak time is a function of capillary density. · Cressoni M, Cadringher P, Colarieti A et al. Is there a need for a CT scan of the pancreatic phase? A perfusion and simulation study of the pancreas, an HCC, and the kidney cortex. Rofo 2025; 197: 1405-1415.
🏷️ 키워드 / MeSH 📖 같은 키워드 OA만
같은 제1저자의 인용 많은 논문 (2)
- The "iodine-derived perfusion" model applied to abdominal tissues with high arterial vascularization: pancreas, kidney cortex, and hepatocellular carcinoma.
- Correction: Is there a need for a CT scan of the pancreatic phase? A perfusion and simulation study of the pancreas, an HCC, and the kidney cortex.
🏷️ 같은 키워드 · 무료전문 — 이 논문 MeSH/keyword 기반
- A Phase I Study of Hydroxychloroquine and Suba-Itraconazole in Men with Biochemical Relapse of Prostate Cancer (HITMAN-PC): Dose Escalation Results.
- Self-management of male urinary symptoms: qualitative findings from a primary care trial.
- Clinical and Liquid Biomarkers of 20-Year Prostate Cancer Risk in Men Aged 45 to 70 Years.
- Diagnostic accuracy of Ga-PSMA PET/CT versus multiparametric MRI for preoperative pelvic invasion in the patients with prostate cancer.
- Association of patient health education with the postoperative health related quality of life in low- intermediate recurrence risk differentiated thyroid cancer patients.
- Early local immune activation following intra-operative radiotherapy in human breast tissue.